Door Station
DIP Switch
es
2 x DIP switches used to set the address of
door station if more than one connected into
the system
ON(1)
=
OFF(0)
=
ON
ON
S
ettings can be done
either before or after installation
There are 6 x DIP switches on the rear of video monitor and they are used to configure the
‘User Code’ for each monitor. Use Tables on the next page for programming monitor ‘User
Codes’. DIP switch 6 is ‘End of Line’ switch, which has to be set ‘On’ on all monitors connected
via ‘Star’ with DBC-4 distributor.
If monitors connected via ‘Daisy chain’, set DIP switch 6 ‘On’ on the last monitor in the chain
only.
Door station DIP
switches
setting
Video
monitor DIP s
witches settings for Multiple Monitor system
(Models Cronus, Leda)
DIP
state
Description
Default setting, ID = 0(00), set to the first Door Station
ID = 1(10), set to the second Door Station
ID = 2(01), set to the third Door Station
ID = 3(11), set to the fourth Door Station
1 2
ON
1 2
ON
1 2
ON
1 2
ON
-
9
-
DIP
state
Setting
DIP
state
Setting
Monitor not at
the end of line
M
onitor is at the end
of the line
1 2 3 4 5
6
ON
1 2 3 4 5
6
ON