"2easy DT-597" - Эта модель предоставляет пользователям простой доступ к многоязычному инструкционному руководству. Вы можете бесплатно скачать руководство на manualshive.com. Удобная и надежная электроника со множеством функций для вашего удобства.
www.intelligenthomeonline.com
Door Station Model DT-597
www
.
intelligenthomeonline.com
2-wire series
Страница 1: ...www intelligenthomeonline com Door Station Model DT 597 www intelligenthomeonline com 2 wire series ...
Страница 2: ...n is made of durable zinc alloy with white back light for illumination The name label with orange back light is covered by a fully secured and flameproof glass plate Parts and Function BUS PL S1 S2 S 1 2 ON Lock Control Jumper Door station Code DIP switches Main Connect Port 1 2 3 Terminal Descriptions 2 T R T R 1 2 3 4 5 6 Microphone 7 Call button 8 9 10 11 12 13 14 Volume adjustment 15 Wall Box B...
Страница 3: ...er positive power S1 The first lock power output S2 The second lock power output S Lock power output Door Station Mounting OPEN CLOSE 90 1 2 3 4 Adjusting Camera Angle Use a screwdriver to loosen the screw Adjust the angle of the camera and tighten the screw Steps 1 Cut out an appropriate size hole and mount the wall box 2 Adjust the camera angle if needed Connect the cables Place name label if re...
Страница 4: ... 90 Open Close 1 2 3 System Wiring and Connections BUS PL S1 S2 S monitor AC PC6 1 Monitor Kit Connection Steps 1 Use the special spanner and move it 900 to loosen the screw 2 Open the front panel 3 Insert the new label 4 ...
Страница 5: ... via daisy chain Models Cronus Leda monitor monitor monitor monitor Code 0 DIP 6 off 1 2 3 4 5 6 ON Code 1 DIP 6 off 1 2 3 4 5 6 ON AC PC6 Code 14 DIP 6 off 1 2 3 4 5 6 ON Code 15 DIP 6 on 1 2 3 4 5 6 ON 1 2 ON ID 00 5 Programming by DIP switches as shown on the diagram enables Intercom by namelist intercom between two specific rooms at a time Alternatively program as Master Slaves for Inner Call ...
Страница 6: ...4 5 6 ON 1 2 3 4 5 6 ON Code 2 DIP 6 on Code 0 DIP 6 on Code 15 DIP 6 on Code 13 DIP 6 on Code 14 DIP 6 on Code 12 DIP 6 on OFF ON OFF ON monitor monitor monitor monitor monitor monitor monitor monitor DBC 4 A B C D DBC 4 A B C D Impedance switch Impedance switch AC PC6 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 ON ID 00 6 ...
Страница 7: ...nlock Mode parameter would be 0 default no need extra programming EB LOCK LOCK 2nd 1ST 2nd EB 1ST Jumper position in Connect two locks 2 3 1 2 3 BUS PL S1 S2 S EB LOCK BUS PL S1 S2 S Jumper position in Connect one lock 2 3 1 2 3 Automated Gates and Magnetic Locks 1 Connect low voltage box of the gates according diagram below 2 Additional power supply for Magnetic lock s according lock specs The Un...
Страница 8: ...8000 Set as master unit 0 8001 Set as slaver unit 1 8002 Set as slaver unit 2 8003 Set as slaver unit 3 8004 Set as guard unit 8005 Set as not guard unit 8006 Panel on as slaver unit called 8007 Panel off as slaver unit called 8008 Date format MM DD YYYY 8009 Date format DD MM YYYY 8010 Set lock mode to 0 8011 Set lock mode to 1 8021 8029 Set the lock time of 1 9s Multi language settings 1 4 7 8 0...
Страница 9: ...e set On on all monitors connected via Star with DBC 4 distributor If monitors connected via Daisy chain set DIP switch 6 On on the last monitor in the chain only Door station DIPswitches setting Video monitor DIP switches settings for Multiple Monitor system Models Cronus Leda DIP state Description Default setting ID 0 00 set to the first Door Station ID 1 10 set to the second Door Station ID 2 0...
Страница 10: ... 4 5 6 ON Specifications Power Supply DC 24V supplied by power supply Power Consumption Standby 60mA Working status 200mA Camera 1 4 ACS 4T image sensor with DSP processor Lock Power 12Vdc 300mA Internal Power Working temperature 10ºC 45ºC Dimensions 188 H 110 W 34 D mm Precautions It is ok to clean stainless steel parts of Door Station with Brasso for example Be careful with glass and plastic par...
Страница 11: ... speaker cable CAT5 CAT6 Minimum requirements 0 5mm cable up to 2mm depends on distance B A C DBC 4 monitor monitor monitor two or four monitors AC PC6 Monitor quantity 20 Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 60 Twisted cable 2x1 mm2 150 150 100 Monitor quantity 20 Cable Usage A B C Twisted cable 2x1 mm2 70 70 70 Twisted cable 2x1 5 mm2 100 100 100 11 ...
Страница 12: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved www intelligenthomeonline com ...