- 2 -
1.1. IN-OUT wiring without any distributor
Code=1, DIP-6=off
Code=31, DIP-6=off
Code=32, DIP-6=on
Code=2, DIP-6=off
ID=00
1 2
3 4 5 6
ON
1 2
3 4 5 6
ON
1 2
3 4 5 6
ON
85~260AC
DPS
PS5
1 2
3 4 5 6
ON
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
1
3
A
4
B
4
1 2
3 4 5 6
ON
CALL
UNLOCK
TALK/MON
IN-USE
4
5
2
1. System Wirings and Connections
Cable Usage
A
B
Twisted cable 2x0.75 mm
2
60
60
Twisted cable 2x1 mm
2
80
80
Cable Usage
A
B
Twisted cable 2x1 mm
2
70
30
Twisted cable 2x1.5 mm
2
70
50
When Monitor quantity < 20
When Monitor quantity > 20
[1]
: Door Station, when there is only one Door Station,
the DIP bit-1 and bit-2 should be set to
00
.
[2]:
Power Supply(PS5), MUST be installed side by
side with the DPS unit.
[3]:
Power Separator, MUST be installed side by side
with the PS5 unit.
[4]:
Monitor, each one with a unique User Code
(Max.32 Monitors), the bit-6 of the DIP should be set
to
0
(off) if the Monitor is not at the end of the bus line.
[5]:
Monitor, the bit-6 of the DIP should be set to
1
(on)
if the Monitor is connected at the and of the bus line.