Page 7 | Instruction Manual 6220312 | 2E mechatronic
Output signal
[mA]
Inclination
Default settings
[°]
Inclination
customer specific
[°]
4
0
Measuring range min
20
360
Measuring range max
1
Error
Error
Operation
The Sensor comes with an analogue current-interface (4-20mA)
Connect Pin 1 with Vcc and Pin 3 with GND.
COM (PIN 2) is either not connected (n/c) or connected with PIN1.
Between I-SIG out (Pin 4) and GND (Pin 3) the output signal can be
measured.
The current limits for the output signal are 3,8mA and 20,2mA
(apart case of error).
In case of error check first the pin configuration.
Supply Voltage
apparent ohmic resistance
Generally
9V
100Ω
12V
250Ω
24V
500Ω