247Security Inc. | 4400 North Point Parkway, Suite # 158, Alpharetta, GA 30022, USA | 1-866-693-7492 | www.247securityinc.com
ZEUS mDVR
USERS MANUAL
7
4. EQUIPMENT TEST
When all of the cameras, cables, and add-on modules have been installed and when the DVR is connected to your
on-site laptop, the completed setup needs to be tested. To begin the test, ensure the DVR’s storage media is
inserted in the DVR and the lock is turned to the locked position and then turn the vehicle’s ignition to ACC, ON or
RUN position. Starting the vehicle’s engine—and, by extension, the alternator to charge the battery—during the test is
not essential. Ensure that you have direct line-of-sight to the front of the DVR to see the LED indicators.
Note: At the first sign of a hazard/malfunction (electrical fire, smoke) immediately turn the vehicle’s ignition OFF.
The Zeus Series DVR normal boot sequence is as follows:
Sequence
Time Elapsed
[minutes : seconds]
Activity
1
0:05
The IGN (ignition) indicator will turn on. The DVR is idling in Stand-By
mode. It is not online or recording.
2
0:15
The PWR (power) indicator will turn on while the IGN (ignition) indicator
will flash, repeatedly. The DVR is now undergoing its boot sequence.
3
0:20
The green POWER indicator on the Event Marker will turn on.
4
0:45
The IGN (ignition) and PWR (power) indicators will turn on solid. The DVR
has completed its boot sequence.
5
0:50
The record light on the front of the DVR will come on.
6
1:00
The amber RECORD light on the Event Marker will turn on solid, also
indicating that the DVR is recording data. The DVR is now ready to record,
or to be serviced through the Ethernet Cable from your laptop. NOTE: ON
THE ZEUS SERIES DVR’S WHEN THE X-CROSS CABLE IS CONNECTED TO
THE DVR FOR CONFIGURING THE BUS AND AIMING CAMERAS, THE UNIT
WILL NOT RECORD, AS SOON AS YOU DISCONNECT THE X-CROSS CABLE
FROM THE DVR WITH-IN 10 SECONDS THE DVR WILL AGAIN BEGIN
RECORDING. THIS CAN BE CHANGED IN THE SET-UP OF THE DVR IN THE
SYSTEM TAB.