Instructions manual

2045Tech S.r.l.
Via delle Cape 3/5 - 30021 Caorle (VE)
[email protected] - www.floome.com

SAFETY INSTRUCTIONS

Use the product only for its intended purpose and in accordance with the instructions for use, which can be viewed by visiting 
the website: http://www.floome.com - This device is only intended to be used for the detection of blood-alcohol content and not 
to determine the capability of an individual to drive also because alcohol consumption is perceived differently from person to 
person. However, it is known that the assumption of alcohol compromises the reflexes and the ability to drive exposing the driver 
and passengers to potential dangers - This device is intended for private use only and it is not designed and/or intended for 
commercial  or  industrial  use.  Use  the  device  only  if  in  perfect  condition.  If  any  parts  are  damaged  or  there  is  a  suspected 

PDOIXQFWLRQLQJGLVFRQWLQXHLPPHGLDWHO\WKHXVHDQGFRQWDFWRQO\TXDOLͤHGSHUVRQQHOWRYHULI\WKHGHYLFHy0DLQWHQDQFHDQG
UHSDLUPD\RQO\EHFDUULHGRXWE\TXDOLͤHGSHUVRQQHOLGHQWLͤHGE\7HFK6UOy7KHGHYLFHFRQWDLQVQRUHSDLUDEOHSDUWVE\WKH
XVHUy$Q\DFWLRQLQWHQGHGWRRSHQWKHGHYLFHZLOOYRLGWKHZDUUDQW\ZKRVHWHUPVFDQEHIRXQGDWKWWSZZZIORRPHFRPy

Never put the device into water or any other liquids, the device is neither waterproof nor water-resistant. To clean the device, use 

RQO\DVRIWFORWK$YRLGFOHDQHUVRUVROYHQWVWKDWFDQGDPDJHWKHGHYLFHy7KHGHYLFHLVQRWVXLWDEOHIRUXVHE\FKLOGUHQ.HHSLW
RXWRIWKHLUUHDFKy7KLVGHYLFHFRQWDLQVVPDOOSDUWVWKDWFRXOGEHVZDOORZHGRULQKDOHGFDXVLQJVXIIRFDWLRQ

PARTS IDENTIFICATION

,Q WKH ͤJXUH LW LV SRVVLEOH WR REVHUYH WKH GHYLFH DQG LWV

enumerated parts:
(1)  main  body  of  the  device,  (2)  silicone  mouthpiece,  (3) 
circular room, (4) fluid outlet and (5) 3.5mm jack interface.

MAINTENANCE

Repair or maintenance of the device can be carried out only 
by experts appointed by 2045Tech S.r.l. Only original parts 
may be used for repair. The device contains no part that 

FDQEHUHSDLUHGE\WKHXVHU$Q\LQWHUYHQWLRQRUWDPSHULQJ

will void the warranty. It is required for the user to respect 
the intervals, and maintenance methods discussed later in 
this manual.

ACCESSORIES AND SPARE PARTS

Only accessories and spare parts explicitly endorsed by 2045Tech S.r.l. are available to the end user for direct application to or 
replacement in the product.

INTENDED USE

7KHGHYLFHLVGHVLJQHGWRHVWLPDWHWKHEORRGDOFRKROFRQWHQW%$&RIDQLQGLYLGXDOE\PHDVXULQJWKHDOFRKROLQKLVEUHDWK
%U$&7KHGHYLFHLVLQWHQGHGIRUSHUVRQDOXVHDQGWKHPHDVXUHPHQWVHVWLPDWHVDQGGDWDVXSSOLHGE\WKHGHYLFHDUHWREH

understood as merely indicative, and not as an evaluation of the state of a person or of his ability to drive.

Rev. 1.1 - 30/03/2015

MEASUREMENT

8VLQJ)/220(

70

LVYHU\VLPSOHDQGWKHDSSOLFDWLRQDYDLODEOHIRUL26$QGURLGDQG:LQGRZVRSHUDWLQJV\VWHPVPDNHVWKH

measurement process absolutely intuitive.

REQUIREMENTS

,QDGGLWLRQWR)/220(

70

LWLVQHFHVVDU\WRRZQDVPDUWSKRQHGHYLFHUXQQLQJDQL26$QGURLGRU:LQGRZV3KRQH

(8.1+)  operating  system.  Through  the  several  application  marketplaces,  which  are  different  depending  on  the  operating 

V\VWHPLWLVQHFHVVDU\WRͤQGDQGLQVWDOOWKHIUHHDSSOLFDWLRQFDOOHG)ORRPHSURYLGHGE\7HFK6UO2QFHWKHDSSOLFDWLRQ
LVLQVWDOOHG\RXPXVWVLJQXSWRFUHDWHDXVHUSURͤOH$QLQWHUDFWLYHJXLGHLVDOVRSURYLGHGGXULQJWKHͤUVWXVHZKLFKGHIDFWR

replaces the present measurement instructions.

INSTALLING/REPLACING THE MOUTHPIECE

The device is provided with a mouthpiece, already installed. To replace it, temporarily or permanently, you can simply rotate it 
180  degrees,  and  pull  it  vertically,  until  detachment.  The  new  mouthpiece  can  be  installed  by  simply  pushing  it  onto  the 
protruded part the previous mouthpiece was attached to.

REQUIREMENTS OF THE SUBJECT TAKING THE TEST

It  is  essential  for  the  accuracy  of  the  measurement  that  the  subject  has  not  ingested  alcoholic  beverages  for  at  least  20 
minutes prior to the test. Residual presence of alcohol in the mouth can affect the measurement, it is therefore necessary to 
rinse with water. Ingesting aromatic drinks such as fruit juices, although not alcoholic, can affect the measurement if ingested 

ULJKW EHIRUH WKH WHVW 3OHDVH QRWH WKDW IRU H[DPSOH WKH FRQVXPSWLRQ RI IRRG FRQWDLQLQJ JDUOLF RU RQLRQ PD\ JHQHUDWH DQ

overestimation of the measurement. Before testing, the subject has to breathe normally, and just before blowing, he has to be 

DEOHWRH[KDOHDQDLUYROXPHRIDWOHDVW/ZLWKVXIͤFLHQWVWUHQJWKDQGDWDFRQVWDQWOHYHO

 

TAKING THE TEST

1. Turn the mouthpiece and extend the 3.5mm jack from the device

$FWLYDWHWKHDSSOLFDWLRQRQ\RXUVPDUWSKRQH
&RQQHFWWKHGHYLFHͤUPO\WR\RXUVPDUWSKRQHYLDWKHPPMDFN
XQWLOLWFOLFNVFRQͤUPLQJDSURSHUFRQQHFWLRQWRWKHGHYLFH

4.  Follow  the  instructions  in  the  application  to  enable  the 

PHDVXUHPHQWSURFHVVLQSDUWLFXODUE\DFWLYDWLQJWKH6WDUWEXWWRQ

5.  Blow  consistently  but  not  too  hard  up  until  the  smartphone 
vibrates or flashes indicating the end of the testing process

:DLWIRUWKHPHDVXUHPHQWWRͤQLVKDQGFKHFNWKHUHVXOW

7. If the presence of an error is mentioned, try to modify the intensity 
or duration of the blow, as suggested by the application, to obtain a 
measurement

MOST COMMON REMEDIES

Should  the  device  present  any  operating  anomalies,  it  is  possible  to  use  this  table  as  a  reference  to  solve  most  common 
problems.

Should the device present further problems, stop using it immediately, and ask for assistance to 2045Tech S.r.l.

SERVICE AND CALIBRATION

1RVHUYLFHRUEDWWHU\UHSODFHPHQWLVUHTXLUHGDQGWKHXVHUFDQQRWDQ\ZD\FDUU\LWRXW,QRUGHUWREHVXUHWKDW\RXU)/220(

70

 

is  always  in  optimal  conditions,  and  can  deliver  you  accurate  measurements,  we  advice  you  to  have  it  calibrated  after 

DSSUR[LPDWHO\WHVWVDQGDQ\ZD\QRODWHUWKDQPRQWKVIURPLWVͤUVWXVH
<RXZLOOUHFHLYHDQHPDLODQGRUQRWLͤFDWLRQRQWKH)/220(

70

 app that will advice you to go to the website www.floome.com 

to buy the recalibration service
2. The service is very straightforward: a recalibration voucher will be generated, which will have printed on it the address of the 
nearest recalibration facility, and a unique code (which will be sent to you by e-mail)
3.  Once  you  have  printed  the  voucher,  you  will  need  to  send  the  device  through  ordinary  mail  or  express  courier  using  the 

VKLSSLQJ DGGUHVV RQ WKH YRXFKHU DQG DWWDFKLQJ WKH VDPH LQ WKH SDFNDJH 3OHDVH EH VXUH WR KDYH D JRRG VKRFN LQVXODWLRQ

material while packing the device to avoid any damage during shipping. Thus, we advice you to choose wisely the shipping 
method, and consider to opt for a shipping insurance.

2QFHUHFHLYHGE\WKHUHFDOLEUDWLRQIDFLOLW\)/220(̵VUHFDOLEUDWLRQSURFHVVVKDOOWDNHDERXWDZHHNDIWHUZKLFK)/220(

70

 

will be returned to you by ordinary or express shipping.

STORAGE

The device must be kept in an environment, which is compatible with its characteristics. It can be stored without being used for 
up to 10 years, but this would compromise the performance of the sensor, that is no longer guaranteed at that point.

CLEANING

The device should never be submerged in liquids. The mouthpiece is the only washable part. It can be cleaned only with neutral 
soap, and has to be reinstalled only once completely dry.

 

 

CE MARKING

T

KLVSURGXFWEHDUVWKH&(0DUNLQJDVLWPHHWVWKHUHTXLUHPHQWVRIWKHUHOHYDQW(8GLUHFWLYHV7KHXVHRIWKH&(PDUNLV

handled by 2045Tech S.r.l. - Via delle Cape 3/5 - 30021 Caorle (VE), Italy. For a copy of the declaration of conformity, 
please visit our website at: http://www.floome.com.

 

 

FCC MARKING

T

KLVGHYLFHFRPSOLHVZLWK3DUWRIWKH)&&5XOHV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQVWKLVGHYLFH

may not cause harmful interference, and (2) this device must accept any interference received, including interference 
that may cause undesired operation.

 

    DISPOSAL OF PRODUCTS

This symbol indicates that this product must not be disposed of with household products. Correct disposal of this product will 
help  prevent  potential  negative  consequences  for  the  environment,  and  human  health,  which  could  result  from  improper 
handling of the product as waste. For more detailed information about the recycling of this product, please contact your local 

FLW\RIͤFH\RXUORFDOZDVWHGLVSRVDOVHUYLFHRUWKHVKRSZKHUH\RXSXUFKDVHGWKHSURGXFW

PROBLEM

Device  is  not  recognized  by  the 
application

0HDVXUHPHQWIDLOVDQGDQHUURULV

displayed on the application

Despite  having  followed  the 
tutorial,  the  measurement  cannot 
be 

completed. 

The 

device 

produces  a  different  whistle  from 
the usual one.

SOLUTION

Try  to  turn  off  and  restart  the 
application  and  try  it  on  another 
smartphone. 

Be 

sure 

the 

application  has  access  rights  to 
the microphone

Follow  the  instructions  on  the 
application  to  improve  the  use  of 
the device.

Verify that no foreign elements are 
present in the whistle chamber. To 
this  purpose,  use  a  cotton  swab 
and  inspect  the  chamber  with  a 
light.

FURTHER ADVICE

If  no  improvement  is  detected, 
verify  that  the  3.5mm  jack 
contacts are cleaned.

If necessary, rely on the interactive 
tutorial provided in the application.

If  foreign  elements  are  not  easily 
removable, remove the mouthpie-
ce and blow in the air outlet to eject 
the elements from the intake.

PRODUCER

This device is designed and manufactured in Italy by:

any communication can be made through the website www.2045tech.com or by email to [email protected].

INTELLECTUAL PROPERTY

The  design  of  the  device  is  protected  by  a  U.S.  design  patent  (US  D706149  S1)  and  the  vortex  flow-meter  by  a  pending 

LQWHUQDWLRQDODSSOLFDWLRQ3&7(3

MISCELLANEOUS

3OHDVHFRQVXOWWKHWHUPVDQGFRQGLWLRQVRIWKHSURGXFWRQZZZIORRPHFRPWRKDYHIXUWKHULQIRUPDWLRQRQWKHZDUUDQW\RWKHU

causes that may alter the results of the tests, etc.

)/220(

70

 is a non-registered trademark used by 2045Tech S.r.l.

TECHNICAL SPECIFICATIONS

0$7(5,$/6

0($685(0(1735,1&,3/(
0($685(0(17,17(59$/
',63/$<,17(59$/

(19,5210(17$/&21',7,216

6$03/,1*

$&&85$&<

:(,*+7

SIZE

32:(5

7KHGHYLFHFKDVVLVLVPDGHRIDQ$%63RO\FDUERQDWHEOHQGZKLFKPDNHVLWVKRFN

resistant, in principle. The mouthpiece is made of a non-toxic solvent-free silicone 
rubber, suitable for lip contact. 
Electrochemical fuel-cell sensor, combined with a vortex whistle flow-meter.

%$&IURPWRJG/

The display interval matches the measurement interval. If a sample with more than 
the maximum measurable concentration is introduced, the text “> .250 g/dL” will be 
shown.
Operating:  10-40°C,  non-condensing  humidity  between  10  and  90%,  ambient 

SUHVVXUHIURPWRK3D6WRUDJHr&

The minimum sampled volume is 0.5L and it requires a duration of the blow of at 
least 2.5 seconds.

0HDVXUHPHQW̵VDFFXUDF\GHSHQGVRQWKHPHDVXUHGYDOXHHJ%$&IURPD
JG/sJG/%$&IURPWRJG/sRIGLVSOD\HGYDOXH
$SSUR[JUDPV
[[PP+[:['

The device does not require any external power source. It is equipped, inside, with a 

EDWWHU\ZKLFKZLOODVVXUHDOLIHRIWHVWVRU\HDUVZKLFKHYHUFRPHVͤUVW

1

3

2

4

5