5
Cocina sin límites, S.L. Barcelona (SPAIN) +34 934296340 www.100x100chef.com
COOL BAR © 2016 V2 ENG
Problems and solutions
If once everything is properly connected to the solenoid, you press start but the device
does not expel gas: check that the bottle is the right type. In case of uncorrect bottle,
change it.
If once everything is properly connected by pressing the solenoid the flux starts and
although ejects gas, it is not chilled and does not frost the cups: check that the gas type
and bottle are correct. Change the bottle. Check if the liquid CO2 is exhausted.
Although gas goes out from the device, the device only works when the gas comes out
in liquid phase state. Check it and make another test with a fully charged bottle.
There is a gas leak from the connection to the bottle: check if the gasket is in good
condition and not damaged. If necessary, replace with a new gasket.
There is a gas leak from some joint sleeves: tighten the connection using two wrenchs.
If after prolonged use, gas escapes from the device without pressing the button: close
the stopcock, purge the circuit and let it stand for 5 minutes. Restart the pressurizing
process. If despite having performed these operations the leak persists, bring to the
Official Technical Service to replace the mechanical part of the solenoid.
If you connect the device to the electrical grid and then after switching the On/Off
button light turns on but the solenoid valve does not work: bring to the Official
Technical Service to replace the electric part of the solenoid.
If you connect the device to the electrical grid and the solenoid valve works but the light
does not turn on: unscrew the top of the device and install a new light bulb.
Any question or technical issue can be sent by email to
SERVICIO TÉCNICO OFICIAL - TECHNICAL SERVICE OR SUPPORT
100%CHEF Rivero, 67 08032 Barcelona
– SPAIN Tel. +34 93 429 63 40