4.2

 Pressure release plug

To open the housing, the pressure 

release plug must be first unscrewed and 
then

pulled 

out 

all 

the 

way 

(Counter-clockwise)

(Fig  1).  This 

provides  a  passage  for  the  air  to  pass 
though  and eliminate  the  pressure 

different  between  the  inside  of  the 
housing  and  the  ambient. The  plug 

consists of an internal double O-ring seal 
on the stainless steel slide shaft.

These  internal  O-rings  form  the 

watertight  seal.  There  is  also  a  large 

outer O -ring under the knob. This O-ring 

serves  to prevent  contamination  of  the 
slide shaft, with dirt, salt etc., and is not 

required  for  watertight  integrity.  If  this 

O-ring should  become detached, it  can 
simply be pushed back in place.

4.3

 Opening levers:

After unscrewing and pulling out the pressure release plug, the lid can be opened. To overcome the 

friction of opening, use lever (Fig. 2) to push against the lid with a cam action. Be sure they are inserted all the 
way flat to the housing before turning to avoid damaging the protrusions on the lid. The body has four holes on 
each corner edges for opening. Gently lever off the lid with the supplied opening lever (Fig. 3) taking care not 

to twist the lid excessively. The lid should be opened keeping it approximately paralleled to the body at all
times, turn first one corner a little, then the other a little, and repeat again until the lid is opened. Remember to 

unscrew and pull out the pressure release plug all the way first, otherwise the air pressure will resist attempts 

at opening. Lay the lid on a flat stable surface after opening.

4.4

 Special note on responsibility for watertight integrity:

Each housing is individually inspected and hydrostatically tested in the factory. The design of the 

main piston O-ring seal is among the most reliable in the industry and the watertight integrity is excellent. This 

special O-ring design provides a perfect seal even if there is any movement between the body and lid due to 

change of ambient pressure. However please note that responsibility for ensuring the integrity of the 
watertight seal lies entirely with the user. 10 BAR accepts no liability for damage to, or loss of any equipment
used with, or placed inside the housing. Users are highly recommended to carry out in-water test of the 

Содержание 400D

Страница 1: ...achined to configure to individual camera model A range of lens ports and controls are fitted to tailor the housing to your camera model 2 Specifications 400D Test Pressure 10 Bar 300 ft Housings are individually tested Closure Design Air Lock Body Material Polycarbonate Overall Size 200 x 300 x 230 mm LxWxH Total Weight Approximately 2 6 Kg Housing only Buoyancy with camera Approximately neutral ...

Страница 2: ...12 13 14 15 Cross Key 16 Setting 17 Shutter 18 Main Dial 19 Mode Dail Power on off 20 Flashlight syn bulkhead 21 Zoom control dial 4 Set up Instructions 4 1 Air Lock The body and lid are designed with the Air Lock System no clip closure arrangement Testing has shown that this arrangement allow the water to exert an even pressure on the O ring Increase the reliability of the watertight seal ...

Страница 3: ... holes on each corner edges for opening Gently lever off the lid with the supplied opening lever Fig 3 taking care not to twist the lid excessively The lid should be opened keeping it approximately paralleled to the body at all times turn first one corner a little then the other a little and repeat again until the lid is opened Remember to unscrew and pull out the pressure release plug all the way...

Страница 4: ...me contaminated As a rule of thumb set up the camera and housing before a day s diving If the housing is required to be opened between dives for changing memory card or re charging batteries make sure the outside of the housing is thoroughly toweled dry before opening up After removing the lid and servicing the camera replace the lid straight away rather than leaving it lying around Before replaci...

Страница 5: ... the lid Fig 8 Remember to ensure the pressure release plug is pulled all the way out while closing otherwise the air cannot escape Squeeze the lid closed all the way with the hissing of expelled air Screw home CLOCKWISE the pressure release plug Fig 9 There is no need to excessively tighten this plug The seal is made by internal O rings The O ring on the underside of the plug is just to keep out ...

Страница 6: ...g Storage The body lid of the housing are made of polycarbonate Polycarbonate was selected for its outstanding strength stiffness hardness and toughness As well as its crystal clear transparency and high gloss surface It has good resistance to weathering although long term exposure to sunlight should be avoided Normal operating temperature range is 3 C to 36 C Storage temperature 10 C to 50 C It i...

Страница 7: ...e The warranty applies only to the housing itself 10 BAR does not accept any liability either implicit or otherwise for any equipment housed inside or used together with the housing In the event of the housing flooding within the period of warranty 10 BAR will repair or replace the housing Please note that disassembly of the housing will invalidate warranty Please fill in the information below and...

Отзывы: