Reposition until the latch is pushing against the hook and lift the lid to push open the back cover 

 

4.3 Special note on responsibility for watertight integrity:   

Each housing is individually inspected and hydrostatically tested in the factory. The design of the main 
piston O-ring seal is among the most reliable in the industry and the watertight integrity is excellent. 
This special O-ring design provides a perfect seal even if there is any movement between the body 
and lid due to change of ambient pressure. However please note that responsibility for ensuring the 
integrity of the watertight seal lies entirely with the user. 10BAR accepts no liability for damage to, or 
loss of any equipment used with, or placed inside the housing.    Users are highly recommended to 
carry out in-water test of the housings without installing of the camera for their first dive after change 
of  new  ports  or  alternation  of  any  new  configuration.  The  test  can be  carried  out by  lowering  the 
housing with ballast to the working depth or dive down to the safe diving range.   

The O-ring seal is the only barrier between the water outside and the air space within the 
camera. It is an effective barrier only if the seal is properly maintained. The O-ring seal 
should  be  inspected  before  every  dive.  The  following  information  is  provided  for  your 
guidance in using and maintaining the O-ring seal.   
 
4.5 Maintaining the O-ring Seal:   

If the main body to lid O-ring is not installed, install the O-ring before diving. This is the only user 
serviceable O-ring. Its care and maintenance is critical to the watertight integrity of the housing. The 
O-ring should be replaced at the service interval (see section on service). If the O-ring is contaminated, 
or not already installed, inspect grease and install the O-ring according to the following guidelines.   

4.4 Inspection, cleaning and re-instillation of the O-ring   

Tools:   

A soft cotton bud or sponge applicator, make sure these are free of all chemicals or contamination such 
as loose fibers, and the tube of silicone grease supplied with the housing are required. Note other types 
of silicone grease specifically for use with underwater camera equipment can usually also be used. It is 
advised to carry out the following procedure on a firm clean level surface, (e.g. at a table), to prevent 
skidding especially useful to have when diving from a boat.   

When to maintain the O-ring seal:   

Remove the O-ring periodically for inspection. It is not necessary to remove, clean and re-install the 
O-ring after every dive provided the O-ring did not become contaminated. As a rule of thumb set up the 
camera and housing before a day’s diving. If the housing is required to be opened between dives for 
changing memory card or re-charging batteries, make sure the outside of the housing is thoroughly 
toweled  dry  before  opening  up.    After  removing  the  lid  and  servicing  the  camera,  replace  the  lid 
straight  away,  rather  than  leaving  it  lying  around.  Before  replacing  the  lid,  make  sure  that  no 
contamination  such  as  dust,  hair,  salt,  sand  etc.  has  fallen  onto  the  O-ring  or  O-ring  recess,  as  a 
precaution  we  recommend  to  inspect  the  O-ring  every  time  the  lid  is  opened  and  to  carry  out  the 
maintenance if necessary.   

Содержание 220ex

Страница 1: ...f a clear polycarbonate allows for visual inspection of camera condition and the O ring seal 10BAR Housings are designed for the ever increasing variety of models of digital still and video cameras Advanced computer aided design and CNC manufacturing technologies ensure precise dimensions Each housing body is first injection molded and then machined to configure to individual camera model A range ...

Страница 2: ...TTL Function Visible main O ring for final pre dive check Double O ring design on all controls Bulkhead and hot shoe plug Accessories Silicone O ring grease Spare main O ring Sync cord Optional accessories Flex Arm Ball Join Arm Compatible Sync cord 3 Function Controls 220EX 1 Higfh Speed Sync press to change mode 2 On Off align the control over the switch press and rotate to turn on or off For th...

Страница 3: ...3 4 Set up Instructions 4 1 Release the Latch with Lock Push the lock lever forward and left up the lid of the latch Fig 3 Fig 4 4 2 Release the latch Fig 5 4 3 Remove the Cover ...

Страница 4: ...he only user serviceable O ring Its care and maintenance is critical to the watertight integrity of the housing The O ring should be replaced at the service interval see section on service If the O ring is contaminated or not already installed inspect grease and install the O ring according to the following guidelines 4 4 Inspection cleaning and re instillation of the O ring Tools A soft cotton bu...

Страница 5: ... replacement O ring can be obtained from 10 BAR If the O ring is contaminated or suspected of being contaminated clean it with a cotton cloth that is free of all chemicals or contamination After cleaning inspect the O ring again Once the O ring has been inspected and verified fit for use apply a SMALL amount of silicone grease to the O ring The silicone grease must be evenly distributed round the ...

Страница 6: ...inspection of the main O ring for contamination Fig 9 Note If the O ring is in good contact a thin black line about 0 5 1mm in width should be visible where the O ring is in contact with the lid Follow this line all the way round the edge of the seal as a final check that the seal is good The housing is now ready for the dive Important Before diving make sure the pressure release plug is pushed ba...

Страница 7: ...he controls avoid excessively rapid movements as this may distort the O ring Also please allow for the fact that the camera takes a few seconds to power on If the camera dose not appear to respond to a control action make sure that no other controls are pressing on the camera i e locking out further actions Wear the wrist strap it is easy to inadvertently let go of the housing especially if you ar...

Страница 8: ...we can assess the severity 6 Service To ensure the continued performance of your housing it should be serviced every year or after every 200 dives whichever is earlier Please note the terms for servicing the housing posted at our website A full service will include Inspection of all components for wears or damage report if repair necessary Cleaning of all sealing surfaces and replacement of all O ...

Страница 9: ...Factory Building 31 33 Ng Fong St San Po Kong Hong Kong Tel 852 2573 3228 Fax 852 2811 9180 Email service 10bar com Web site http www 10bar com Please keep this document for future reference Note due to continuous improvement the latest model housing may differ slightly form those described in this document Copy to be returned to 10 Bar Underwater Housings ...

Отзывы: