2. Specifications 5 D Mark II 

 

Test Pressure   

10 Bar (300 ft.) Housings are individually tested 

Closure Design   

Double O-rings, Key-hole Lock

 

Body Material   

6061 Aluminium 

Overall Size   

137 x 190 x 167 mm (LxWxH) / 130mm (Port only) 

Total Weight   

Approximately 2.55 Kg (Housing only) 0.90Kg (Port only) 

Buoyancy (with camera) 

Approximately neutral in salt water 

Features 

Visible main O-ring for final pre-dive check   
Double O-ring design on all controls   
Bulkhead and hot shoe plug for External 580-EX e-TTL strobe   
Standard Zoom Port18~55mm Lens 

Accessories 

5D Mark II Opening key / Lever

 

 

Silicone O-ring grease   
Spare main O-ring   
Carrying bag   
Cleaning Kit 

Optional accessories 

Semi-Dome Port for xxxxxxx mm Lens   
580-EX e-TTL Flashlight Housing   
Flex Arm   
Ball-Joint Arm   
Synchronous Cord     

 

3. Function Controls 5 D Mark II 

1. 

Flashlight syn bulkhead

 

 

2. 

Flashlight syn bulkhead 

 

3. 

Mode Dial

 

4. 

Metering / White Balance

 

5. 

AF.Drive

 

6. 

ISO speedset

 

 

7. 

Light

 

8. 

Main Dial

 

 

9. 

Shutter

 

 

10. 

Screen Display

   

11. 

Menu

 

 

12. 

Picture Style

 

13. 

INFO

 

14. 

Playback

 

15. 

Erase

 

16. 

Print 

 

17. 

Viewfinder eyepiece

 

18. 

Control dial 

 

19. 

AF Mode

   

20. 

Auto Exposure

 

21. 

AF point selection 

22. 

Setting 

23. 

Turntable

 

    24. 

Power

 

On / Off 

25. 26. 27.

 

28. 

Key Hole Lock

 

 

Содержание 5 D Mark II

Страница 1: ... of a clear polycarbonate allows for visual inspection of camera condition and the O ring seal 10 BAR Housings are designed for the ever increasing variety of models of digital still and video cameras Advanced computer aided design and CNC manufacturing technologies ensure precise dimensions Each housing body is first injection molded and then machined to configure to individual camera model A ran...

Страница 2: ...strobe Standard Zoom Port18 55mm Lens Accessories 5D Mark II Opening key Lever Silicone O ring grease Spare main O ring Carrying bag Cleaning Kit Optional accessories Semi Dome Port for xxxxxxx mm Lens 580 EX e TTL Flashlight Housing Flex Arm Ball Joint Arm Synchronous Cord 3 Function Controls 5 D Mark II 1 Flashlight syn bulkhead 2 Flashlight syn bulkhead 3 Mode Dial 4 Metering White Balance 5 AF...

Страница 3: ...e diving range The O ring seal is the main barrier between the water outside and the air space within the camera It is an effective barrier only if the seal is properly maintained The O ring seal should be inspected before every dive The following information is provided for your guidance in using and maintaining the O ring seal 4 2 Maintaining the O ring Seal If the main body to lid O rings are n...

Страница 4: ... tool make sure the tool has no sharp edges Alternatively use the flats of the thumbs to gently stretch the O ring on two faces thus making a small loop protruding a few mm The loop can then be grasped between finger and thumb to pull the O ring over the lip l Clean the O ring recess the square groove where the O ring sits with a cotton bud l Inspect the O ring all the way round its surface for da...

Страница 5: ...s simple and easy to use and adding security To open the housing turn the levers of the lock perpendicular to the wall of the housing until the lock is released on both sides Opening Key Pull out the lid by holding on the grip near the lock ...

Страница 6: ...ction of the on of button on the body of the housing Slide the hot shoe plug into the hot shoe Note If you find that the buttons do not align properly with the controls please check again that the camera is properly seated to the limit of the guide rail Slide the camera into the body along the rubber packing Make sure the camera body reach the limit and test the function of the On Off button on th...

Страница 7: ...lever and turn until the lever is parallel to the side wall of the housing After replacing and locking the lid make a final visual inspection of the main O ring for contamination Note If the O ring is in good contact a thin black line about 0 5 to 1mm in width should be visible where the O ring is in contact with the lid Follow this line all the way round the edge of the seal as a final check that...

Страница 8: ...e a day s diving If the housing is required to be opened between dives for changing memory card or re charging batteries make sure the outside of the housing is thoroughly toweled dry before opening up After removing the lid and servicing the camera replace the lid straight away rather than leaving it lying around Before replacing the lid make sure that no contamination such as dust hair salt sand...

Страница 9: ...icals may harm Polycarbonate the housing should never be exposed to the following classes of chemicals benzene toluene xylene chlorinated hydrocarbons methanol any other solvents strong acids and bases For long term storage please remove the main o ring from body 5 4 Transportation When transporting by air please ensure the housing is not sealed to allow the air pressure to equalize Either remove ...

Страница 10: ...n the information below and return a copy to 10 Bar Underwater Housing at the address below to validate the warranty Copy to be retained by user Housing Type Date of Purchase Serial Number Labelled inside housing Dealer Owner s Name E mail Owner s Address Tel Fax Office Showroom Unit C 2 F Wing Hin Factory Building 31 33 Ng Fong St San Po Kong Hong Kong Tel 852 2573 3228 Fax 852 2811 9180 Email se...

Отзывы: