26
MANUGENH3 0N3
User manual
VER 1.05
Power Supply
Rated Voltage
Max interruption of the supply
Starting current
Power consumption
Electrical insulation
24VDC ± 25%
10ms
250mA @ 24V
3.12W (typ) = 130mA @ 24V
No
Emergency Stop Button
2 N.C. contacts
Enabling Device
3 positions switches, 2 N.O. contacts
State Selector
16 state BCD coded
Handwheel (optional)
40 detents per turn
Override potentiometer
2 linear potentiometers
MECHANICS
Handheld terminal color
Body structure: RAL 7035; Rubber part:
RAL7016
Outer dimensions
Length
Height
Width
220mm
50mm
130mm
Weight
(without cable)
700g (H3 without handwheel)
710h (H3 with hadwheel)
ENVIRONMENT
Temperature
Operating temperature
Trasport and storage tempera-
ture
+5° to +45°C
-20° to +70°C
Relative humidity
Operating
Transport
Max 95%: non-condensing
Max 95%: non-condensing
Operating Altitude
Max 3000m
Protection Degree
IP64
Flame resistance
Handheld terminal housing fulfils UL 94-HB