INSTALLATION
INSTRUCTIONS
AND SAFETY INFORMATION
F O R T H E V I K I N G Q -7 G AT E O P E R ATO R
C L A S S I I , C L A S S I I I , A N D C L A S S I V
Heavy-Duty Commercial Vehicular Slide Gate Operator
Страница 1: ...INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING Q 7 GATE OPER ATOR C L A S S I I C L A S S I I I A N D C L A S S I V Heavy Duty Commercial Vehicular Slide Gate Operator ...
Страница 2: ...lide gates up to 7000 lbs and 120 ft in length at 100 duty cycle under extreme conditions This efficient operator provides a solution for high traffic commercial and industrial slide gate applications The Viking Q 7 gate operator offers efficiency and technology combined in a single package ...
Страница 3: ...Q 7 Vehicular Gate Operator Revision Q7NXMN10 G February 2016 ...
Страница 4: ...sor DNXTS10 14 Q7 Gearbox Q7GB70 15 Q7 Motor VAQ7MO 16 Brush Kit VAQ7MBK 17 Electronic Positioning Sensor 2 EPS2 VNXSLEPS2 18 Motor Breaker VAQ7MB20 19 Chain 50 x 10 x 3 Nickel Coated Q4C50CHK 20 Sprocket 50B23 Q7SP50 21 Idler Pulley VAQ4IP 22 Idler Pulley Bushing VNXQ7IB20 23 Alarm DUAL10 24 Battery Switch DUMRS20 25 Q7 Power Box Assembly VNXQ7PBA 26 Receptacle 120V VQ120R 27 Motor Power Switch D...
Страница 5: ...mits 8 MOTOR 9 BATTERY SWITCH disconnects batteries from the charging circuit during troubleshooting 10 POWER BOX ASSEMBLY removable convenient access to the power supply components 11 MOTOR POWER SWITCH switch breaker provides additional protection for the motor circuitry 12 EMI FUSE main power supply protection 13 J BOX high voltage power supply connection 14 MANUAL RELEASE HANDLE convenient mec...
Страница 6: ...OL TERMINAL BLOCKS accessory connections pg 29 32 42 44 15 MASTER SLAVE Terminal Block wired master slave connection pg 22 16 CONTROL BOARD MOUNTING HOLES secures and grounds the control board 17 Siren Terminal Block Vikings UL Siren is connected here 18 ON BOARD 3 BUTTON STATION controls the gate during set up 19 AUX PWR Terminal Block used for solar applications in motion warning devices pg 19 2...
Страница 7: ...e Communication 22 Wireless Communication Options 23 CONTROL BOARD SETUP 24 27 Initial Settings 24 25 Obstruction Detection Sensor Primary Entrapment Protection 26 Heater Lock Mode 27 ACCESSORY CONNECTIONS 29 35 Re Open Photo Beam Vehicular Safety 29 Radio Receiver Typical 30 Anti Tailgate Open Commands Guard Station 31 Viking Loop Rack 32 Guidelines for Loop Installations 33 Magnetic Lock Lock So...
Страница 8: ...erator only when a The operator is appropriate for the construction of the gate and usage Class of the gate refer to page 9 b All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet 1 83 m above the ground to prevent a 2 1 4 inch 57 2 mm diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjac...
Страница 9: ...to page 10 d Use only Miller Edge photoelectric beams refer to pages 10 11 10 For a gate operator utilizing a contact sensor edge sensor or like in accordance with section 31 1 1 of the UL 325 standard a One or more contact sensors shall be located where the risk of entrapment or obstruction exists such as a the leading edge trailing edge and post mounted both inside and outside of a vehicular hor...
Страница 10: ...them carefully as they contain important indications for the safe installation use and maintenance These instruction must be kept and forwarded to all possible future users of the system This product must be used only for that which it has been expressly designed Any other use is to be considered improper and therefore dangerous The manufacturer cannot be held responsible for possible damage cause...
Страница 11: ...t shall contain specific instructions concerning the proper method of charging Install the gate operator only when The operator is appropriate for the construction of the gate and the Usage Class of the gate UL325 Gate Operator Classifications GLOSSARY RESIDENTIAL VEHICULAR GATE OPERATOR CLASS I A vehicular gate operator or system intended for use in garages or parking areas associated with a resi...
Страница 12: ... Consult the installation manual of the sensor for detailed information about the usage installation and maintenance This type of installation will only reverse the gate approximately 12 in the opposite direction it was traveling when the sensor is triggered This type on installation is to protect against entrapment only and does not reverse the gate all the way back to its limits when the photo b...
Страница 13: ...nsor monitored terminals STEP 1 Connect the secondary entrapment protection sensor s to the Viking control board as illustrated below Up to four 10K resistor based sensors can be wired in parallel Proceed with the following Learn Process If the number of connected sensors does not match the display If the Stop LED is flashing If the error message ERR UL SENSOR is displayed LEARN PROCESS With the U...
Страница 14: ...al Stop button within the sight of the gate away from moving parts of the gate and out of reach of children a Controls intended for user activation must be located at least six feet 6 away from any moving part of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to...
Страница 15: ...ght of the gate 2 At a minimum height of 5 feet so small children are not able to reach it and 3 At least 6 feet away from all moving parts of the gate Specifications Maximum Gate Length 120 ft Maximum Gate Weight 7000 lb Operating Temperature 20 F 28 C to 160 F 71 C Power Requirements 115 VAC 230 VAC 8 0 amp 4 0 amp Includes 3 amp load on receptacle Single Phase 50Hz 60Hz DO NOT allow pedestrian ...
Страница 16: ...re the stable operation of the operator and a minimum of 4 above level grade to avoid any flooding of the machinery 3 Provide a sufficient number of conduit pathways for all low power accessories such as loop detector leads maglock non contact sensors contact sensors safety and other commands Also provide conduit for the power supply to the operator DO NOT run low voltage and high voltage wiring i...
Страница 17: ...stalled at the close position This will be used as a reference to relearn the limit positions if the gate has been operated manually while released or if the EPS2 Cable has been disconnected Suggested Positive Stop Types Wheel stop affixed to the track Gate catch plate yoke or receiver NOTE Viking Access Systems does not provide any form of positive stops ...
Страница 18: ...e are guarded or screened from the bottom of the gate to a minimum of 6 feet 1 83 m above the ground to prevent a 2 1 4 inch 57 2 mm diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in the open position GATE OPERATOR INSTALLATION ...
Страница 19: ...irm that there is adequate spacing for the guide rollers and that there are no restrictions throughout the travel of the gate GATE OPERATOR INSTALLATION STEP 2 Chain Installation Before welding the provided chain brackets make sure the chain will be in a straight line with and at the same height as the chain leaving the gate operator rollers STEP 1 Before securing the chassis to the concrete pad o...
Страница 20: ...te wires Tips for proper ground installation To minimize the effects caused by lightning follow these guidelines Use a ground rod to provide a ground reference Consult your city code and be aware of under ground services in the site of the gate operator to prevent inconveniences Always use a single bonding point for grounding All ground wires must be as short and as thick as possible Prevent unnec...
Страница 21: ...rt VA SOCHP and its individual components are NOT RECOMMENDED for the Q 7 operator Contact Viking Access Systems or your local solar provider for further information B Disconnect the operators power harness and use the Solar Harness Connect the batteries in series 24VDC ELECTRICAL INSTALLATION Tip Solar efficiency can be increased by activating the Pre Warning feature The Aux Pwr terminals will pr...
Страница 22: ...erated manually while released or if the EPS2 Cable has been disconnected 2 In the event of a complete power failure including battery backup the limit positions may have may been cleared and will need to be reset as described STEP 1 Connect the Motor Harness to the Control Board a OPEN LEFT Connector if the gate opens to the Left when viewed from inside b OPEN RIGHT Connector if the gate opens to...
Страница 23: ...n the installed Positive Stop reference To Readjust the Open Limit 1 Clear the current limit setting by holding down the Open Limit button until the LED is flashing 2 Repeat STEP 3 on page 20 to set the limit IMPORTANT If the gate has been manually released and re engaged 1 The Open Limit LED will be illuminated solid and the Close Limit LED will be flashing 2 The gate will not run in the open dir...
Страница 24: ...s Technical Tip DO NOT set the Timer and or Overlap features on both operators Control Boards Only turn these features on at the Master Control Board MASTER SLAVE SETUP CABLE REQUIREMENTS 2 Conductor wire 18 AWG or better Shielded overall foil Drain Wire non insulated or bare wire Master Board MS1 MS2 Conduit between Master and Slave Slave Board MS1 MS2 Drain Wire Shielded Cable Conduit ...
Страница 25: ... SETUP REQUIRED ADD ON 1 Choose option A or B A Viking Konnect Wireless Master Slave Kit PART VA KONNECT MS B Viking Blue Wireless Master Slave Kit PART VA BLUE MSKT 2 Antenna Extension Cables 2 PART VA RPSMA Connect the Modules provided to the V K plug play connection of each operators Control Board It is not important which board the master or slave module is placed on Green LEDs will be illumin...
Страница 26: ...e the gate Speed Motor Speed Increases or decreases the speed of gate travel Overlap Overlap Delay Delays the gate from opening for the selected amount of time from 1 6 seconds Typically not used on slide gates For Master Slave application the control board that has this feature turned on is the master and will close first ODS Obstruction Detection Sensor Sets the amount of force required to trip ...
Страница 27: ... power is restored Last Open Power Failure Option Opens the gate automatically when the battery backup voltage is critically low IMPORTANT Regardless of the power failure options chosen the gate can be moved manually with a relatively low amount of force by following the steps for Manual Release as outlined at on page 11 EXT Available for future developments Pre Warning Initiates two options for a...
Страница 28: ... consecutive entrapment events sensed by the Inherent Entrapment Protection of the Gate Operator The audio alarm will sound for a period of 5 minutes or until a Stop command has been actuated See page 12 for more information When the Obstruction Sensor detects an obstruction it will 1 Stop the gate s movement and reverse it momentarily 2 Bring the gate to a resting position 3 Disable the Hold Open...
Страница 29: ...Turning this feature ON will secure the gate at the closed position preventing unauthorized manual entry NOTE If the application requires the gate to be held open for any reason set the HEATER ON for both limit positions IMPORTANT A POSITIVE STOP must be used on the gate at the limit position s the HEATER has been set for HEATER OPN ON To set the heater to turn on at the Open Limit 1 Use the Diagn...
Страница 30: ...VIKING TECHNICAL SUPPORT 1 800 908 0884 28 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 31: ...ons to the control board and individual input terminal functions refer to Appendix A pages 42 43 Note regarding Photo Beam types Fail Safe type connect the N C terminal of the photo beam to the Re Open terminal on the control board Typically these are the reflective type photo beams Fail Secure type connect the N O terminal of the photo beam to the Re Open terminal on the control board Typically t...
Страница 32: ...pens the gate b Second command stops the gate and c Third command closes the gate d Any subsequent commands will continue in the same order to control the gate This type of configuration is not recommended for commercial installations Open Only 2 By having the radio receiver connected as illustrated and with the Hold Open Timer ON see page 24 Each command of the radio transmitter is ALWAYS AN OPEN...
Страница 33: ... will stop the gate when the vehicle triggers the sensor then closes the gate when the vehicle leaves the sensor preventing unauthorized vehicles from entry Guard Station All three buttons must be a Normally Open N O type of switch and can share the same common C connection to GND Open Commands Exit Fire and Strike input terminals all provide an open command to the control board Any device connect...
Страница 34: ...oop Rack that plug in type loop detectors can be connected to This provides a convenient alternative to the box type loop detectors that would need to be wired to the control board Viking does not provide either type of loop detectors Loop Rack Part VA LR Loop Rack Wiring Harness Part VA LRH ACCESSORY CONNECTIONS ...
Страница 35: ...unctionality of the vehicular loop detector 4 Twist the lead wire at least 6 turns per foot 5 Use BACKER ROD to minimize damage to the loop detector wire prior to using the sealant 6 Place the loop detector wire and adjust the sensitivity of the vehicular loop detector unit in a way to minimize the effects of the gate over the loop detector wire IMPORTANT Some of the following parameters may affec...
Страница 36: ... external power supply or plug in transformer must be used for the magnetic lock or lock solenoid Plug the transformer into the 120VAC receptacle provided at the operators Power Box This will prevent rapid drainage of the battery in the event of power failure The control boards Magnetic Lock relay is rated for 10A 250VAC Magnetic Lock Lock Solenoid TECHNICAL TIP The Magnetic Lock Relay LED will in...
Страница 37: ...s Gate Operator reaches its Open Limit 3 The Gate Operator will delay to close until the Barrier Arm reaches its Close Limit SYNCHRONIZATION WITH B 12 STEP 2 Figure A At the B 12 Barrier Arm Operator connect the primary device that will be used as the OPEN input STEP 1 Figure A B Connect the Gate Operator to the Viking B 12 Barrier Arm Operator as illustrated STEP 4 Figure C D Connect Viking B 12 ...
Страница 38: ...but the circuit is open 7 8 3 Battery Low OFF Normal Condition SOLID Batteries are low Check power supply to the operator pg 18 19 1 2 FLASHING Batteries critically low Check power supply to the operator pg 18 19 1 2 4 POWER SOLID Normal Condition FLASHING Operator is running on batteries only pg 18 19 1 2 OFF No power to control board 1 2 4 5 5 Radio OFF Normal Condition SOLID Control Board is re...
Страница 39: ...als at the moment 15 Diagnose OFF Normal Condition FLASHING Errors have been detected Check LCD Display for ERR messages pg 40 16 Close Limit OFF Gate is not at the close limit position SOLID Gate is at the close limit position FLASHING Close limit position has been erased or not set pg 20 21 6 17 Open Limit OFF Gate is not at the open limit position SOLID Gate is at the open limit position FLASHI...
Страница 40: ...he Model of the unit System Status Messages GATE IS IDLE Gate is stopped between limits GATE IS OPENING Gate is opening GATE IS CLOSING Gate is closing GATE IS OPENED Gate is at the limit open position GATE IS CLOSED Gate is at the limit close position STOP BY OBSTRUCT Gate stopped due to an obstruction sensor event 11 12 13 STOP BY OVERLOAD Gate stopped due to an overload of the gate system 11 12...
Страница 41: ...RR Indicates that the Electronic Positioning Sensor EPS needs to be tuned Error rate is displayed as a percentage Speed __ Shows the percentage of speed set by the Speed adjustment on the control board pg 24 OVERLAP _ _ SEC Shows the number of seconds set by the Overlap Adjustment on the control board This feature is not available on slide gate operator models ODS SENS ___ Shows the force setting ...
Страница 42: ...PS has a potential connection problem c The EPS has the wrong cable harness ERR EPS2 MISSING Missing or damaged EPS2 cable harness 14 17 ERR ___ LIMIT Indicates that the open OPN close CLS or both NO limits are cleared and need to be set 6 ERR FUSE 30 AMP Motor Power Switch has been tripped 7 11 12 ERR EMI NO EMI No EMI board detected 15 ERR EMI NO FUSE 8 Amp main fuse is blown on Power Supply Pan...
Страница 43: ...ices from the control board to determine if the control board is responding to an input or problem with the external device or wiring pg 29 32 36 37 11 Check the gate track and chain for any debris or cause for resistance Check the ODS setting on the control board pg 8 12 26 12 Check that the gate can be moved manually with low resistance throughout its full length of travel pg 8 17 13 Check the l...
Страница 44: ...ion Device Terminal 28V DC Positive GND DC Negative GND Relay Common C Radio N O If Timer OFF Open Stop Close If Timer ON Open Reopen if closing UL see pages 10 11 N O If input is brief Stops gate then Reverses 12 inches If input is longer Stops gate does not reverse Re Open N O If stopped No function If closing Stops then Opens gate ATG Anti Tailgate N O Input is received Stops gate if closing In...
Страница 45: ...e connected to the Input Terminal 3 Terminal Block On the Viking control board a removable block containing multiple terminals 4 Relay The component of an access control or safety device that provides an input or command to the Viking control board 5 C Relay Common Terminal This is the relay terminal that makes contact a short to the N O terminal when the device is activated Always wire this relay...
Страница 46: ...VIKING TECHNICAL SUPPORT 1 800 908 0884 44 Common Radio Receivers Connections Appendix B Common Radio Receivers Connections Appendix B ...
Страница 47: ... information regarding solar energy refer to www nrel gov solar Batteries Fuse Voltage 24V Amp Hour 35Ah minimum Fuse 10A minimum Replace the operators batteries with 35Ah or greater Panels Voltage 24V Wattage 80W minimum Cut the wires coming from the toroidal transformer Connect the solar panel cables to the power harness as shown IMPORTANT The chart provided can be used as a guide for the number...
Страница 48: ...rator Connecting the AC Surge Pro in parallel to the EMI Board provides a dual layer of protection from surges up to 20 000 Volts 10 000 Amps Part VA SURGEPROAC VIKING KONNECT Diagnostic Tool On site remote access to the operator from the convenience of a compatible hand held device With the Viking App this tool becomes a wireless extension of the control board allowing you to view and change sett...
Страница 49: ... both hardware and software to ensure operation and functionality protection from lightning short circuit and power surges and our exclusive helical gearing offering the highest efficiency rating in the industry Our entire product line is continually modified and improved based on the latest technology and our customer s valuable feedback The results are products that offer accuracy efficiency reliab...
Страница 50: ...Up to 120 maximum gate opening 100 duty cycle 100 cycles of operation on backup battery 2000 lb gate and 40 length Intelligent speed control with smooth start and stop self adjust system Anti Tailgate and Operation Pre Warming features On Board LCD Display provides diagnostics operator status settings and real time volt and amp readings Intelligent obstruction detection with adjustable sensitivity...