background image

 

Pakton Technologies 

 

ABN 66 405 694 842

 

1 Helium Street, Narangba Qld 4504

 

PO Box 408, Narangba QLD 4504

 

Tel: (07) 3888 3793

 

Fax: (07) 3888 4330

 

Email: [email protected]

 

www.pakton.com.au

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Remote Monitor 

PTE0700 

SECURITY ELECTRONICS 

User Manual 
 
PTE0700 V2 Series 
Remote Monitor 

Содержание PTE0700 V2 Series

Страница 1: ...4 842 1 Helium Street Narangba Qld 4504 PO Box 408 Narangba QLD 4504 Tel 07 3888 3793 Fax 07 3888 4330 Email sales pakton com au www pakton com au Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor ...

Страница 2: ...Connections 10 Stand Alone Operation 11 Alarm Panel Operation 11 Solar Panel Operation 12 Low Fence Voltage Set Point Calibration Automatic set point 12 Low Fence Voltage Set Point Calibration Manual set point 12 Delay Calibration automatic and manual low fence voltage alarm set point 13 8 0 ELECTRIC FENCE MONITOR OUTPUTS 14 LED Visual Display 14 Relay Output 14 0 5V Analog Output 15 4 20mA Analog...

Страница 3: ...15 10 09 Page 3 of 18 2 0 List of Tables Table 1 Model Features 6 Table 2 Specifications 9 Table 3 Relay Connections 14 Table 4 PTE0700 RS232 Connections 15 ...

Страница 4: ... Page 4 of 18 3 0 List of Figures Figure 1 Output Terminal Locations 10 Figure 2 Stand Alone Operation 11 Figure 3 Alarm Panel Operation 11 Figure 4 Solar Panel Operation 12 Figure 5 PAE036 LCD Expansion PCB 17 ...

Страница 5: ...y also enable system designers to include electric fence voltages as inputs into remote telemetry or SCADA systems This series consists of four models the PTE0700 701 702 and 703 The features of the various models can be found in the Features section of this document The PTE0700 series can also be customised to meet your own requirements for quantity purchases Suitable Applications for the PTE0700...

Страница 6: ... setting a relay Alarms failing fence by setting a failsafe relay Current output 4 20mA proportional to 0 10kV input Voltage output 0 5V proportional to 0 10kV input Simple RS 232 Data Output SCADA friendly RS 232 Data Output Hardware IP65 weather proof wall mountable enclosure 12V DC Powered Adjustment Low Fence Voltage alarm set point or automatic self setting Adjustable delay from Low Fence Vol...

Страница 7: ...n a quickly rising voltage Adjustable Delay from Low Fence Voltage to firing alarm is the adjustable amount of time the Electric Fence Monitor waits after the fence fails before it raises an alarm For example If the delay is set to six seconds and the fence voltage goes low for only three seconds no alarm is raised The alarm would only be raised if the fence voltage stayed below the Low Fence Volt...

Страница 8: ...to 0 10kV input as above for voltage analogue inputs RS232 output means that the data collected by the Electric Fence Monitor can be transmitted to other equipment in RS232 format The serial port found on most computers uses the RS232 format You can easily use a computer to collect save and display this information ...

Страница 9: ...12V lead acid battery Min measurable input voltage 0 3 kV Input voltage measurement Peak to peak Relay output Dry changeover contacts 30V 1A 500mA recommended Energiser compatibility Compatible with Low impedance energisers that meet AS3350 2 76 or IEC60335 2 76 Max 4 20mA loop excitation voltage Supply Voltage 0 7V Accuracy 5 design target Drift less then 1 over temperature range Temperature rang...

Страница 10: ...ble from the Electric Fence Monitor s red input binding post to the electric fence and from the Electric Fence Monitor s green input binding post to a good earth connection If possible it is best to connect to the same earth that your energiser is using Output Connections The Electric Fence Monitor s Output Connections are visible on the bottom edge of the circuit board and consist of a row of plu...

Страница 11: ...can be configured for either Stand Alone or Alarm Panel Operation Stand Alone Operation In Stand Alone Operation the relay outputs can be used to switch a siren or a strobe on when an alarm condition is raised If both a siren and a strobe is desired they can be connected in parallel provided the power supply or battery is big enough to power both Figure 2 Stand Alone Operation Alarm Panel Operatio...

Страница 12: ... the twelve volts supply and switching back on The Electric Fence Monitor has now automatically set the Low Fence Voltage Alarm Set Point and is now monitoring the Electric Fence You can test its operation by deliberately placing a short on your electric fence the Electric Fence Monitor will raise an alarm It is recommended that Automatic set point NOT be used for security purposes If the fence st...

Страница 13: ...fence s voltage and needs to be lowered slightly Do this by turning the Volts trimmer anticlockwise until the Greed Pulse LED begins to flash again If the alarm came on it will self clear in about 30 seconds Delay Calibration automatic and manual low fence voltage alarm set point After setting the Volts trimmer or using automatic setpoint as above The Green Pulse LED should be flashing Switch off ...

Страница 14: ...e Common C Normally Closed NC and Normally Open NO When the fence is operating correctly and when there is no power supply for the Electric Fence Monitor the C and NC terminals are shorted and the NO terminal is not connected to anything When the fence voltage goes low and the Electric Fence Monitor raises an alarm the relay toggles connecting the C and NO terminals and disconnecting the NC termin...

Страница 15: ...ransmitter Wire the output so that current flows from positive supply 5 12V through the input of the 4 20mA receiver equipment and then to terminal I The current range of 4 20mA will linearly represent a fence voltage range of 0 10kV ie Fence Voltage 0 625 x Loop Current 2 5 Take care to read the instructions for the receiving analog input device RS232 Output The RS232 Output is available in two f...

Страница 16: ...TX voltage 4 ASCII CR where STX is binary 2 and CR is a carriage return At turn on the PTE0703 also transmits some diagnostics information see below This can be ignored by the receiver as it is not prefaced by an STX Please note that while the PTE703 transmits 4 significant digits the basic accuracy is only 8 bit 2 digit In the print out below 6117 represents 6 1kV When no pulse is seen for over 4...

Страница 17: ...nnects via a 10 way ribbon cable to the expansion header on the PTE0700 PCB It is secured to the PCB via 4 standoffs provided The display will show the low voltage setpoint and the actual fence voltage It also displays a battery symbol when the supply voltage falls below a satisfactory level Note that the LCD board must be removed to adjust the Low Voltage and Delay set point trimmers Figure 5 PAE...

Страница 18: ... your proof of purchase or contact the store of purchase or distributor For assistance If you have any operational problems difficulties etc you can phone fax or email your questions or comments to Pakton Phone 07 3888 3793 International 61 7 3888 3793 Fax 07 3888 4330 International 61 7 3888 4330 E mail sales pakton com au Mailing address PO Box 408 Narangba QLD 4504 Australia Street address 1 He...

Отзывы: