Intelligent Solar Charge Controller 

User’s Manual 

 

 

 

 

 

Please read this manual carefully before you use this product. 

www.realsolar.ru (812) 921-52-96,(812) 924-27-83

Summary of Contents for CM30D series

Page 1: ...Intelligent Solar Charge Controller User s Manual Please read this manual carefully before you use this product www realsolar ru 812 921 52 96 812 924 27 83 ...

Page 2: ...Catalogue 1 Product Introduction 4 2 Installation 5 3 Operation 6 4 Common Fault and Handling 12 5 Technical Data 13 www realsolar ru 812 921 52 96 812 924 27 83 ...

Page 3: ...application requirements CM30D series controller has following features Image of LCD graphic symbol Simple button operation Automatic Identification of System Voltage level Intelligent PWM charging mode Over current protection Adjustable charge discharge control parameters Settable Operating mode of Load Battery reverse discharge protection Battery Low Voltage Disconnection LVD Battery reverse con...

Page 4: ... the battery by cables with right polarity The battery indicator light on the controller will be on if successfully connected otherwise to check and reconnect 2 4 To connect the solar panel and the controller by cables with right polarity If there is sunshine the battery indicator light will be on in a circular manner to indicate right connection otherwise to check and reconnect 2 5 To connect you...

Page 5: ...d Status for Loads Stop the battery charging Power to the load status The system is working correctly Float charging the battery Load Load timer control Solar Panel Battery charge capacity instruction Load sensor control Battery www realsolar ru 812 921 52 96 812 924 27 83 ...

Page 6: ...his button can perform the function of add in the parameter setting state This button can on or off load in the main interface It can perform the function of minus in the parameter setting state Overall unit state Floating charge voltage Low voltage recovery Battery types Load mode Low voltage protection Figure 1 www realsolar ru 812 921 52 96 812 924 27 83 ...

Page 7: ...ace calling off the parameter interface after long press the button again The numbers stop flashing 3 1 Overall unit state This interface shows the overall unit state pictured at right It is the default interface after correct power on showing charging and discharging state 5 bars battery power indication and the voltage of the battery 3 2 On or off the load You can use the button on the faceplate...

Page 8: ...ng The floating voltage value will be conserved by controller 3 4 Viewing and setting of recovery after under voltage As pictured at right the recovered voltage is showed After the controller performs the function of under voltage protection the output of the load will be recovered as soon as the battery voltage recovers to higher than the under voltage value long press the button 5seconds numbers...

Page 9: ...nserved by controller 3 6 Viewing and setting of load working mode As shown in the figure at right the interface of load mode is displayed and different numbers represent different load modes 24h represents Normal Mode the load is always in power under the fault free circumstance 1h 23h represents Light Control with Time Control Mode at this mode the controller will start the load after darkness a...

Page 10: ...different types of Battery b01 Sealed battery default type for the controller b02 Gel battery B03 Flooded battery long press the button 5seconds numbers start flashing at this interface to activate the battery type and use the button to adjust the parameter long press the button again The numbers stop flashing to call off parameter interface after finish setting Setting value will be conserved by ...

Page 11: ...t shows up and flash on the screen it means the occurrence of overcurrent or short circuit The controller will stop output and enter overload protection state Solution After solving the problem of output short circuit and reducing the load press the button to restore power to the load 4 3Battery overvoltage and handling shows up and flash on the screen means the battery input voltage of the contro...

Page 12: ...7 6V USB output 5V 1A LVD 10 7V 21 4V Installation cable area 7 AWG 16mm 2 LVR 12 6V 25 2V Working Temperature 20 50 Boost Voltage b01 Sealed 14 4V 28 8V Dura tion 2hours Storage temperature 30 70 b02 GEL 14 2V 28 4V Humidity 10 90 NC b03Flooded14 6V 29 2V Size 95mm 181 mm 42 mm HVD 15 5V 31 0V Mounting hole spacing 64 mm 150 mm Φ5 HRD 15 0 30 0V Weight 230g www realsolar ru 812 921 52 96 812 924 ...