background image

FM3256

0521

Supersedes

1119

12 VOLT DC BATTERY BACKUP PUMP

INSTALLATION INSTRUCTIONS

SEE BELOW FOR 

LIST OF WARNINGS

1.  Testing for ground. As a safety measure each electrical outlet should be 

checked for ground using an Underwriters Laboratory listed circuit analyzer, 
which will indicate if the power, neutral and ground wires are correctly 

connected to your outlet. If they are not, call a qualified, licensed electrician.

2.  For your protection, always disconnect the power supply from its power 

source before handling the components of your DC backup pump or the 
primary pump.

3.  Installation and servicing of electrical circuits and hardware should be 

performed by a qualified, licensed electrician. 

4.  All electrical and safety codes must be followed including the National 

Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the battery and battery 

connection at least once a month. Batteries contain acid, 

and caution must be taken when handling.

6.  Risk of electric shock. These pumps have not been investigated for use in 

swimming pools and marine areas.

7.  Prop65 Warning for california residents: Cancer and Reproductive Harm- 

www.P65Warning.ca.gov.

1.  Make sure there is a properly grounded 115 V receptacle available. Do 

not use primary pump circuit. The location must be within 6' (1.8 m) of the 
control box and battery. The power supply for your DC control system 
plugs directly into the 115 V outlet. DO NOT USE AN EXTENSION CORD.

2.  Make sure the 115 V electrical supply circuit is equipped with fuses or 

circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do not use 

in septic tanks to pump effluent or in sewage pits to pump sewage.

4.  Repair and service of your DC backup system should be performed by an 

authorized service station.

5.  The installation of DC automatic backup pumps requires the use of a variable 

level float switch for operation. It is the responsibility of the installing party 

to ensure that the float switch will not hang up on the pump apparatus 

or pit peculiarities and is secured so the pump will turn “on” and “off”. 

It is recommended that the pit be 18" (45.7 cm) in diameter or larger to 
accommodate both a primary and a DC backup pump.

6.  For indoor use only.

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

CAUTION

  Turbulence caused by high-velocity incoming water can 

cause sump pumps to airlock. If this condition exists, the incoming water 

must be baffled to avoid excessive turbulence.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

© Copyright 2021 Zoeller

®

 Co. All rights reserved.

This equipment has been tested and found to comply with the limits for a class 

B digital device, pursuant to part 15 of the FCC Rules. These limits are designed 

to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can radiate radio frequency 

energy and if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following 

measures: 

- Reorient or relocate the module/ product.

- Increase the separation between the equipment and module / product.

- Consult the dealer or an experienced radio / TV technician for help.

157390-A

Summary of Contents for AquaNot 507 Key

Page 1: ...stallationofDCautomaticbackuppumpsrequirestheuseofavariable level float switch for operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and is secured so the pump will turn on and off It is recommended that the pit be 18 45 7 cm in diameter or larger to accommodate both a primary and a DC backup pump ...

Page 2: ...XPRESSED WARRANTY Some states do not allow limitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state...

Page 3: ...ith battery and eyelet connectors on battery wire leads On batteries with different sized posts the positive terminal is the larger post 3 8 10mm diameter The smaller post 5 16 8mm diameter is the negative terminal This will be indicated on the battery Apply grease to the terminals to help prevent corrosion 12 Connect the plugs for the pump operational switch and power supply into the appropriate ...

Page 4: ...Upon release of the float switch the pump will shut off Be sure there are no obstructions around the float 5 Complete the final testing of your installation by ensuring the primary pump is still disconnected from power Unplug the Key controller from the 115 V wall outlet Run water into the sump until the DC backup pump is activated by the operational float switch Check all connections for leaks 6 ...

Page 5: ...IN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT KEY CONTROLLER OUTLET CONTROLLER AQUANOT KEY CONTROLLER FIGURE 2 SK3262 OPERATIONAL FLOAT DC PUMP LED TEST BUTTON BLACK LEAD NEGATIVE FLOAT STATUS LED SILENCE BUTTON WHITE LEAD POSITIVE AC POWER ADAPTER PORT 30 AMP FUSE DC PUMP SYSTEM READY LED BATTE...

Page 6: ...g both the silence reset and test button at the same time for 5 seconds will cause a factory reset on the controller AQUANOT KEY Solid Flashing Off System Ready No Faults Green AC off with no faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pump Running Yellow Pump Fault Red Float Status Float Fault Red The LEDs will display inf...

Page 7: ...d approximately 1 second after the pump starts to run e Push the Silence Reset button The alarm will turn off f The pump will shut off after the water level is lowered and the float drops to the off position g Hold silence reset button for 3 seconds to reset the controller and clear any alarms or indicators 2 Plug the controller and the primary pump into the wall outlet a The primary pump may come...

Page 8: ..._______ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ ________________________________________________________________________...

Reviews: