background image

H0723600_REVC - 2022/05

More documents on:

www.zodiac.com

SIROCCO

2

Instructions for installation and use

 - 

English

Dehumidifier

Translation of the original instructions in French 

EN

Summary of Contents for WD002088

Page 1: ...H0723600_REVC 2022 05 More documents on www zodiac com SIROCCO2 Instructions for installation and use English Dehumidifier Translation of the original instructions in French EN...

Page 2: ......

Page 3: ...ards The installer is responsible for installing the appliance and for compliance with national installation regulations Under no circumstances may the manufacturer be held liable in the event of fail...

Page 4: ...as covered by the Kyoto Protocol with a Global Warming Potential GWP 2088 European regulation EU 517 2014 In order to comply with the applicable standards and regulations in terms of the environment a...

Page 5: ...fetyrequirementsofthevariousapplicabledirectives are indicated on the information plate All this information must be recorded in the appliance s installation manual which must be kept in its technical...

Page 6: ...ttings 28 5 4 I Wiring diagrams 29 Tip to make it easier to contact your retailer Write down your retailer s contact details to help you find them more easily and fill in the product information on th...

Page 7: ...5 Specifications 1 1 I Description SIROCCO2 Wall mounting rail screws x5 6 mm Filter Base Hot water coil kit Electric heater kit Remote control kit Built in kit Included Available as an accessory EN...

Page 8: ...5T A 1 060 mm 1 410 mm B 300 mm C 800 mm A C B C A C Front Side Rear A B A B Top Bottom User interface Blower grid Integrated wall mounting rail Condensate drainage outlets Filter extraction grid Lev...

Page 9: ...13 7 20 5 6 8 Option hot water battery inlet water temperature at 70 C minimum 90 C maximum Power W 7 070 8 110 11 090 11 090 Water flow m h 0 3 0 35 0 47 0 47 Head loss kPa 27 85 38 85 34 51 34 51 M...

Page 10: ...ke Caution 230 V AC appliances must be outside volume 1 see below Risk of stratification height of the room 4 to 5 metres mechanical ventilator unit or extractor height of the room 5 to 8 metres ceili...

Page 11: ...sitioning it Place the straps in the positions shown by the dotted lines in the following diagram Information weight of appliance The left side of the appliance as seen from the front is heavier than...

Page 12: ...ndensate drainage line The angle should be sufficient to ensure a correct flow Drainage takes place through the intermediary of a syphon or funnel Outlets underneath the appliance Ensure the syphon is...

Page 13: ...11 2 4 I Access to the electrical connection terminal boards EN...

Page 14: ...curve rating to be defined according to the table in 1 3 I Technical specifications with a suitable dedicated residual current device circuit breaker or switch Additional protection may be required d...

Page 15: ...d upstream To do so use the hot water coil kit available as an accessory For the connection consult the manual supplied with the kit 2 6 2 Electric heater option This option allows the dehumidifier to...

Page 16: ...esentation of the display screen and function keys Description Multi function display On off or back key Up or de activation key for the heating function Down or de activation key for the Silence mode...

Page 17: ...pliance starts Only on Sirocco 5T models three phased This operation must be only be carried out by a qualified professional The phase order controller protects the compressor It is forbidden to inver...

Page 18: ...revious screen Information list of menus Menu Description Restriction USER Menu dedicated to users for managing setpoints EASY Menu intended for qualified professionals so that they can configure the...

Page 19: ...back to the previous screen Press a number of times to return to the home screen Information home screen update When the heating kit is confirmed electric heater or hot water coil the home screen is u...

Page 20: ...on you will have to 1 First connect the pool shutter switch see 2 5 1 Connecting the pool shutter switch 2 Activate the pool shutter mode In the EASY menu browse with the or keys until you reach the P...

Page 21: ...ation In the EASY menu browse with the or keys until you reach the P26 setting then press SET to confirm Using the or keys choose the desired duration in minutes The default duration is 30 minutes Not...

Page 22: ...e displayed on the screen corresponds to the relative humidity The ambient temperature can also be simultaneously displayed C To do this just set the heating mode to Hetr or coiL see 3 3 2 Configuring...

Page 23: ...an 3 seconds SET Browse with the or keys until you reach the USER menu then press SET to validate Browse with the or keys until you reach the setting to change refer to the Information list of setpoin...

Page 24: ...turns to the initial screen The duration of the Silence mode is set at 2 hours The Standard mode is automatically reactivated after this 2 hour period to restore a suitable dehumidification regime a n...

Page 25: ...arried out at the user s expense by a qualified technician 4 1 1 Monthly user maintenance Visually check the condensate drainage and check that the drainage tube is correctly positioned Check for clog...

Page 26: ...sequence of phases on the distribution network or on the existing electrical installation is detected The appliance then goes into fault mode see 5 2 Alarm display Clean the outside of the whole unit...

Page 27: ...on the thermodynamic principle which transforms part of the absorbed energy into heat which is then transferred to the ventilated air flow The appliance begins defrost ing The dehumidifier s cooling...

Page 28: ...ter the Selection menu Press twice Press SET to enter the ALARM menu Press SET to find out the number of alarms in progress If the screen remains identical there is only one alarm in progress If the f...

Page 29: ...ty fan Automatic A14 High pressure Clogged filter Obstructed air inlet Cooling circuit problem Automatic A15 Low pressure Cooling circuit problem Automatic A16 Fan speed Faulty fan Electric power unst...

Page 30: ...Easy Inst P16 Type of ventilation Intermittent Permanent Easy Inst P25 Test mode Stop Start 0 Stop 1 Start Easy Inst P26 Test mode duration Minutes Easy Inst P44 Type of heating dsbL No heating option...

Page 31: ...5 X2 4 X2 1 c pro 3 HP BP C C B A GND ITB 5V 12V GND M1 M2 M3 M4 M5 M6 M7 M8 M9 A01 A02 A03 A04 S2 S3 S4 X9 5 X9 6 X9 3 X9 4 X9 1 X9 2 PE L N PE 10 V 10 V MLI GND Vitesse 230 VAC 1 2 3 4 5 6 1 1 2 2 3...

Page 32: ...X2 1 c pro 3 HP BP C C B A GND ITB 5V 12V GND M1 M2 M3 M4 M5 M6 M7 M8 M9 A01 A02 A03 A04 S2 S3 S4 X9 5 X9 6 X9 3 X9 4 X9 1 X9 2 PE L N PE 10 V 10 V MLI GND Vitesse 230 VAC 1 2 3 4 1 1 2 2 3 3 4 4 S1 K...

Page 33: ...X2 1 KM2 HP BP C C B A GND ITB 5V 12V GND M1 M2 M3 M4 M5 M6 M7 M8 M9 A01 A02 A03 A04 S2 S3 S4 X9 5 X9 6 X9 3 X9 4 X9 1 X9 2 PE L N PE 10 V 10 V MLI GND Vitesse 380 VAC 1 2 3 4 1 1 2 2 3 3 4 4 L2 L3 M...

Page 34: ...larm C4 C5 Electrical resistor C6 Compressor COP Check the order of the phases KM1 Compressor contactor KM2 Contactor for electric option M1 Humidity sensor M2 Room sensor M3 Evaporator sensor M4 Air...

Page 35: ......

Page 36: ...rty of their respective owners ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE Votre revendeur Your retailer Mod le appareil Appliance model Num r...

Reviews: