background image

1. INSTALLING THE BATTERY

Press battery door release in with your finger or a coin and lift up to remove door.
Place a new 9V battery into the compartment and press into place.
Replace battery door and snap shut.
Zircon

®

 stud finders and detectors, particularly those with LCD screens, require and 

consume a great deal of current from batteries.
For optimal performance, brand-new, recently purchased alkaline batteries are strongly 

recommended for use in these tools.
If you are experiencing any trouble with your tool, please replace the battery in your 

tool with a brand-new one, or e-mail [email protected].

2. SELECTING THE MODE

Move selector switch to the desired mode: STUD SCAN for finding wood or metal 

studs; METAL SCAN for locating metal; or AC SCAN for locating hot AC wiring.
Move selector switch to the Off position when not in use to prevent the tool from  

accidentally powering on and wearing down the battery.

3. FINDING A STUD

Always scan for studs with the scanner placed flat against the wall. Move the mode 

switch to STUD SCAN, place the tool against the wall, then press and hold the handle.  

Wait for beep to confirm calibration has completed before moving tool.

Slowly slide tool across surface. EDGE display will  

illuminate, indicating location of the stud edge.

Continue sliding tool. When the centre of  

stud is located with three bars on the  

Signal Strength Indicator, the buzzer will sound,  

and the four middle bars, CENTER display,  

and SpotLite

®

 

Pointing System will illuminate.

In cases of deeper studs (or thicker walls) two bars  

will show on the Signal Strength Indicator and only  

the SpotLite

®

 Pointing System and four middle  

bars will illuminate. If you still can’t locate a stud,  

try the next step.

Quickly (within one second) release and re-press 

the handle down. The scanner will enter the  

High Sensitivity Mode

 and the STUD SCAN Mode  

Indication will flash continuously. The centre of a  

very deep stud will be indicated by the four middle  

bars illuminating.

4. TIPS FOR PROPER OPERATION

For optimum scanning results it is important to properly hold MultiScanner

®

 

i

700 and 

move slowly when scanning. The following tips will ensure accurate scanning results:
•  Grasp the handle with your thumb on one side and your fingers on the other side.  

Make sure your fingertips are resting on or above the running board and not touching 

the surface being scanned or the scanning head of the tool.

•  Hold the tool straight up and down, parallel to the studs, and do not rotate the tool.

•  Keep tool flat against the wall and do not rock or tilt the tool when slowly sliding across the surface being scanned.
•  Make sure your other hand or any other part of your body is not touching the surface being scanned. This could  

interfere with the tool’s performance.

5. CALIBRATING THE TOOL

MultiScanner

®

 

i

700 constantly monitors the subsurface environment 10 times per second and automatically recalibrates, 

when needed, to successfully find the centre of studs in OneStep

!

•  Place MultiScanner

®

 

i

700 against the wall and press the handle until it lays flat against the wall. Pressing the tool to lay 

flat against the wall will automatically power on the tool via the internal on/off switch.

•  Once powered on, tool will automatically perform all calibrations. The LCD will display all icons until calibration is 

complete. Upon completion of calibration, the SpotLite

®

 and buzzer will momentarily activate and the tool will begin 

continuous measurements. Continue to press the tool flat against the wall and begin scanning.

Note: It is important to wait for calibration to complete (1–2 seconds) before moving the scanner. 

• ACT

(Auto Correcting Technology)—During scanning, the tool will automatically  

recalibrate itself when needed. This recalibration is usually transparent and no  

indication is made. If the tool is initially calibrated near a stud and then moved away  

(it will detect the density of the wall decreasing), an arrow icon will be illuminated,  

indicating the direction of the missed stud.

6. WORKING WITH DIFFERENT MATERIALS

Wallpaper:

 The MultiScanner

®

 

i

700 functions normally on walls covered with wallpaper or fabric, unless the materials are metallic foil,  

contain metallic fibers, or are still wet after application. 

Wallpaper may need to dry for several weeks after application.

Lath & plaster:

 Due to irregularities in plaster thickness, it is difficult for the MultiScanner

®

 

i

700 to locate studs in STUD SCAN Mode.  

Change to METAL SCAN Mode to locate nail heads holding laths to stud. If plaster has metal mesh reinforcement, MultiScanner

®

 

i

700 will  

be unable to detect through that material.

Textured walls or acoustic ceilings:

 When scanning a ceiling or wall with an uneven surface, place thin cardboard on the surface to be  

scanned and scan over the cardboard. Calibrate with cardboard in place. 

Wood flooring, subflooring, or gypsum drywall over plywood sheathing:

 Use STUD SCAN Mode and move the tool slowly. The signal 

strength indicator may only display 1 or 2 bars when the tool locates a stud through thick surfaces.
MultiScanner

®

 

i

700 cannot scan for wood studs and joists through carpeting and pad. In problematic situations, try using METAL SCAN to locate 

nails or drywall screws that line up vertically where a stud is positioned.

Note: Sensing depth and accuracy can vary due to moisture content of materials, wall texture, and paint.

Do not rely exclusively on the detector to locate items behind the scanned surface. Use other information sources to 

help locate items before penetrating the surface. Such additional sources include construction plans, visible points 

of entry of pipes and wiring into walls, such as in a basement, and in standard 40 and 60 cm stud spacing practices.

Dual SpotLite

®

 

Pointing System

Backlit LCD 

Mode Selector 

Switch

Battery  

(back of unit)

Stud Scan Mode 

Indication

Stud Edge or  

Center Indication

AC Mode &  

WireWarning

®

 

Indication

Metal Mode 

Indication

Auto Recalibration  

Indication

Signal Strength 

Indicator

Erasable Marker

Mark Button

Running Board

Metal Sensor 

(back of unit)

The MultiScanner

® 

i

700 OneStep

 features three scanning modes:

• Stud Scan Mode: Locates the centre and edges of wood and 

metal studs up to 38 mm deep

• Metal Scan Mode: Detects and locates ferrous (magnetic) metal 

up to 76 mm deep and non-ferrous (non-magnetic) metal up to 

38 mm deep

• AC Scan Mode: Detects and locates live AC wires up to  

50 mm deep

• WireWarning

®

 Detection automatically detects and alerts the 

user to live AC wires in Stud Scan and Metal Scan modes

7. SCANNING IN METAL MODE

Note: When scanning for metal studs, use STUD SCAN Mode to quickly locate the centre and 

edges of wood or metal studs. Use METAL SCAN Mode only to determine if studs are wood 

or metal. In METAL SCAN Mode, only metal drywall screws will be found in wood studs,  

while metal will be indicated everywhere on a metal stud.

METAL SCAN Mode has interactive calibration to adjust its sensitivity to metal which  

can be used to find the precise location of metal objects in walls, floors, and ceilings. 

Maximum sensitivity is ideal for quickly finding the approximate location of metal.  

However, the user can reduce sensitivity by turning on the tool closer to metal. The reason 

for reducing sensitivity is because with less sensitivity, the area where metal is indicated 

will be smaller. But in both cases, the metal target is in the centre of the area where the 

tool indicates metal is present.
1. 

(Figure A)

 Press the tool flat against the wall and slowly slide the scanner across the 

surface. Mark the spot where the display bars peak. If it is a strong target, the SpotLite

®

 

Pointing System will also shine a beam of light and a steady beep will sound. Continue in 
same direction until display bars reduce. Reverse direction and mark the spot where the 
display bars peak from the reversed direction. The midpoint of the two marks is the location 
of the centre of the metal object.
If the unit indicates metal over a large area, you can refine the scanning area to more accu-

rately locate the metal target.
2. 

(Figure B)

 To further pinpoint the location of the metal target, scan the area again. 

Release the handle and then turn the unit back on, this time starting on the wall over  

one of the previous marks. This will reset the tool to a lower sensitivity and make the  

scan more precise. 
3. 

(Figure C)

 Scan in both directions as in Step 1. The area indicated should become  

smaller so you can more precisely identify the metal location. This procedure can be repeat-

ed to narrow the field even further.

Note: Small targets or targets deep within the surface may only illuminate some of the bars 

and not the centre line or audio tone. In this case, use the highest indication to determine 

the metal position. 

8. SCANNING IN AC MODE

As with METAL SCAN Mode, AC SCAN Mode has interactive calibration and works in the 

same manner. 
1. 

(Figure A) 

Press the tool flat against the wall and slowly slide the scanner across the 

surface. Mark the point where you get the highest AC indication (the most bars on the 

screen). If it is a strong target, the SpotLite

®

 Pointing System will also shine a beam of  

light and a steady beep will sound. Continue in same direction until display bars reduce. 

Reverse direction and mark the spot where the display bars peak from the reversed direc-

tion. The midpoint of the two marks is the location of the centre of the live AC wiring.  

If the unit indicates live electricity over a large area, you can refine the scanning area to more accurately locate the live  

AC wiring.
2. 

(Figure B) 

To further pinpoint the location of the live AC wiring, scan the area again. Release the handle and then turn  

the unit back on, this time starting on the wall over one of the previous marks. This will reset the tool to a lower sensitivity  

and make the scan more precise. 
3. 

(Figure C) 

Scan in both directions as in Step 1. The area indicated should become smaller so you can more precisely  

identify the location of live AC wires. This procedure can be repeated to narrow the field even further.  

Note: AC SCAN Mode will only detect live (energized) AC wiring.
WireWarning

®

 Detection

 

Zircon’s WireWarning

®

 Detection feature works continuously in all modes. When live AC voltage is detected, the AC Alert warn-

ing icon will appear in the display. If scanning begins over a live AC wire, the AC indicator will flash continuously.

Electrical field locators may not detect live AC wires if wires are more than 50 mm from the 

scanned surface, in concrete, encased in conduit, present behind a plywood shear wall or  

metallic wall covering, or if moisture is present in the environment or scanned surface. 

DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL WIRES IN THE WALL. DO NOT TAKE ACTIONS 

THAT COULD BE DANGEROUS IF THE WALL CONTAINS A LIVE ELECTRICAL WIRE. ALWAYS TURN OFF 

THE ELECTRICAL POWER, GAS, AND WATER SUPPLIES BEFORE PENETRATING A SURFACE. FAILURE TO FOLLOW THESE 

INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS INJURY OR PROPERTY DAMAGE. 
Always turn off power when working near electrical wires.

9. MARKING THE LOCATION

Once an object is located, you can MARK the location by gently pulling down the MARK button with the tip of your finger. 

Pulling back the MARK button will cause a pencil point to extend from the front of the handle, placing a short erasable line  

on the wall.

10. CHANGING THE MARKER TIP

Pull and hold the MARK button to fully extend the marker tip. Grasp the marker and pull it off the marker post. To install a  

new marker tip, pull and hold the MARK button to fully extend the marker post. Push the new marker onto the marker post.   

Note: MultiScanner

®

 

i

700 comes with three spare marker tips.These tips are stored in a compartment located behind  

the battery

.

11. REMOVING OR REPLACING THE SCANNING HEAD

MultiScanner

®

 

i

700’s scanner head may be removed from the handle to facilitate cleaning or repair. Or the scanning head  

may also become separated from the handle if accidentally dropped or twisted. Follow the directions below to replace the scan-

ning head:

To remove head:

 Place the back of the head in the palm of one hand, and grasp the body of the unit in the other hand.  

Slowly and gently lift and turn the body, removing one arm from the socket at a time.

To replace the head:

 Align the end of the arms over the sockets and gently snap them back into their sockets,  

one arm at a time.

arnoldingallsmoranvilleadvertising

Figure A

Figure B

Figure C

Detects other objects  

besides studs in  

STUD SCAN Mode. 

Finds more targets  

than there should be.

Area of voltage appears 

much larger than actual 

wire (AC only).

Difficulty detecting 

metal.

Image of metal object  

appears wider than  

actual size.
Constant readings of  

studs near windows  

and doors.
You suspect electrical  

wires, but do not  

detect any.

• Electrical wiring and metal/plastic pipes may be  

near or touching back surface of wall.

• Static charge may develop on drywall, spreading 

voltage detection as much as 30 cm laterally 

from each side of an actual electrical wire.

• Tool calibrated over metal object.

• Metal targets too deep or small.

• Metal has greater density than wood.

• Double and triple studs are usually found 

around doors and windows. Solid headers are 

above them.

• Wires are shielded by metal conduit, a braided  

wire layer, or metallic wall covering.

• Wires deeper than 50 mm from surface might  

not be detected.

• Wires may not be live.

• Scan the area in METAL and AC SCAN modes to determine if metal or  

hot AC is present.

• Check for other studs equally spaced to either side 30, 40, or 60 cm apart or the 

same stud at several places directly above or below the first.

Use CAUTION when nailing, sawing, or drilling in walls, floors, and ceilings  
where these items may exist.

• To narrow detection, turn unit off and on again at the edge of where wire was first 

detected and scan again.

• Place your free hand flat against wall near tool during the entire scan to drain static.

• The scanner may have been calibrated over a metal object, reducing sensitivity.  

Try calibrating in another location.

• Scan in both horizontal and vertical directions. Metal sensitivity is increased when  

metal object is parallel to sensor, located under Zircon logo.

• To reduce sensitivity, follow Step 7 and recalibrate MultiScanner

® 

i

700 over either of 

first two marks. (Metal mode only.)

• Detect outer edges so you know where to begin.

• Try METAL SCAN to see if you can find metal, wire, or metal conduit.

• Always turn off the power when working near electrical wires.

• Try turning on switches to outlet.

• Try plugging a lamp into outlet and turning on switch.

12. HELPFUL HINTS

 

(See also number 4, Tips for Proper Operation)

 

Situation

Probable Cause

Solution

MultiScanner

®

 

i

700 

OneStep

Multifunction Wall Scanner

GB

WARNING

LIMITED 2 YEAR WARRANTY

Zircon Corporation, (“Zircon”) warrants this product to be free from defects in 

materials and workmanship for two years from the date of purchase. Any in-warranty 

defective product returned to the place of purchase with proof of purchase date will 

be replaced at retailer’s option.This warranty is limited to the electronic circuitry 

and original case of the product andspecifically excludes damage caused by abuse, 

unreasonable use or neglect. This warranty is in lieu of all other warranties, express 

or implied, and no other representations or claims of any nature shall bind or obligate 

Zircon. Any implied warranties applicable to this product are limited to the two year 

period following its purchase.

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR 

CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR MALFUNCTION 

OF THIS PRODUCT.

www.zircon.com 

[email protected]

© 2017 Zircon Corporation • P/N 62099 • Rev C 07/17

ZirconCorporation

ZirconTV

ZirconTools

 | 

ZirconToolPro

ZirconTools

Visit www.zircon.com for the most current instructions.

ACT, CenterVision, MultiScanner, OneStep, SpotLite, StudSesnor, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.

WARNING

WARNING

Reviews: