background image

www.zi

mm

er-instruments.com

1

|

16

2

.

Input and Output screens

In normal operation the user is presented with display test screen followed by version screen

to one of the output screen. These screens may be scrolled through one at a time

by pressing the “

Up key” or “

Down key”.

Screen 2 : Version Screen

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

INPUT x012

O/P 12 y012

A

A

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

Table 1: Measured parameters

Volt

Voltage

Measured parameters

Unit of Measurement

Screen 1 : Display Test

Output 1 as Voltage

Screen 3 : Voltage Input and

Output 1 as Current

Screen 4 : Voltage Input and

Output 2 as Current

Screen 6 : Voltage Input and

Output 2 as Voltage

Screen 5 : Voltage Input and

ON   O/P1  O/P2

COM

Zimmer 

PRO

 

-V

INPUT x012

O/P 12 y012

A

A

ZIMMER

 

PRO

 

-

V

Programmable Transducer

Installation & Operating Instructions

1. Introduction

The

 

Zi

mm

er

 

PRO

 

-

V

 

is  a panel mounted 43.5X 65.5mm

 

Transducer.

The

 

Zi

mm

er

 

PRO

 

-

V

 

is used to measure and  convert

 

AC

 

Voltage input  into an

 

proportional  DC current or  voltage output signal.

 

Output signal generated

 

is proportional

to the

 

True RMS(upto 15th Harmonic) of the input Voltage.

Input Voltage and Output Voltage/Current is displayed on LCD and indicated by LED’s.

Section

Contents

1.

Introduction

2.

Input and Output screens

3.

Programming

3.1.1 Password Protection

3.1.1.2

New / Change Password

3.1.3  Communication Parameter selection

3.1.3.1 Address Setting
3.1.3.2   RS 485 Baud rate
3.1.3.3   RS 485 Parity selection

7.

Specification

5.

Installation
5.1

EMC Installation Requirements

5.2

Case Dimensions and Panel Cut-out

5.3

Wiring

5.4

Auxiliary Supply

5.5    Fusing
5.6    Earth / Ground Connections

6.

Connection Diagrams

RS 485 ( ModBus )

4.

15030988_Rev.A - 10/11

3.1.1.1   Password verification

3.1.2 Potential Transformer parameter selection

3.1.2.2   Potential Transformer secondary value

3.1.2.1   Potential Transformer primary value

3.1.4  Output Type selection

3.1.4.1   Output 1 Type selection
3.1.4.2   Output 2 Type selection

3.1.5  Input parameter selection

3.1.5.1  End value of input
3.1.5.2  Start value of input
3.1.5.3  Elbow Function Selection
3.1.5.4  Elbow value of input

3.1.6  Output parameter selection

3.1.6.1.1  End value of output 1
3.1.6.1.2  Start value of output 1
3.1.6.1.3  Elbow value of output 1

3.1.6.1   Output 1 parameter selection

3.1.6.2.1  End value of output 2
3.1.6.2.2  Start value of output 2
3.1.6.2.3  Elbow value of output 2

3.1.6.2   Output 2 parameter selection

Zi

mm

er

 

PRO

 

-

V

 

can be configured and

 

programmed at site for the following :
PT

 

Primary ,PT

 

Secondary,

Input parameters (i.e start, end and

elbow value of Input) and Output

 

parameters(i.e as Voltage or as Current
and start, end and elbow value of outputs).

The front panel has two push buttons through
which

 

the

 

user

 

may

 

scroll

 

through

 

the

 

output screens and configure the product.

1.1 LED Indication

Green LED

continuous ON

Aux. Supply healthy

condition

Output1 voltage

Output1 Current

Output2 voltage

Output2 Current

Green LED

continuous ON

Red LED

continuous ON

Green LED

continuous ON

Red LED

continuous ON

O/P 2

ON

O/P 1

LED

LED OPERATING

CONDITION

LED OPERATING

STATUS

3.1 Programming via Front LCD & Tow keys

3.2 Programming Via Programming port

ON   O/P1  O/P2

COM

Zi

mm

er

 

PRO

 

-V

INPUT x012

O/P 12 y012

A

A

INPUT

O/P 1

A

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

INPUT x012

O/P 12 y012

A

A

INPUT

O/P 1

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

INPUT x012

O/P 12 y012

A

A

INPUT

O/P 2

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

INPUT x012

O/P 12 y012

A

A

INPUT

O/P 2

A

ZIMMER

PRO

-

V

PRO

-

V

Summary of Contents for PRO -V

Page 1: ...nnection Diagrams RS 485 ModBus 4 15030988_Rev A 10 11 3 1 1 1 Password verification 3 1 2 Potential Transformer parameter selection 3 1 2 2 Potential Transformer secondary value 3 1 2 1 Potential Transformer primary value 3 1 4 Output Type selection 3 1 4 1 Output 1 Type selection 3 1 4 2 Output 2 Type selection 3 1 5 Input parameter selection 3 1 5 1 End value of input 3 1 5 2 Start value of inp...

Page 2: ...ssword prompt for first digit Denotes that digit will be flashing from 0 through to 9 the value will wrap from 9 round to 0 In the special case where the Password is 0000 pressing the Up key when prompted for the first digit will advance to the Password Set Confirmed screen Enter Password first digit entered prompt for second digit Denotes that digit will be flashing from 0 through to 9 the value ...

Page 3: ... COM Zimmer PRO V INPUT x012 O P 12 y012 A A ON O P1 O P2 COM Zimmer PRO V INPUT x012 O P 12 y012 A A ON O P1 O P2 COM Zimmer PRO V INPUT x012 O P 12 y012 A A Enter New Change PT Primary value first digit entered Denotes that digit will be flashing Pressing the Down key will scroll the value of the second digit from 0 through to 9 the value will wrap from 9 round to 0 Pressing the Up key will adva...

Page 4: ...ows the user to set RS485 parameter for instruments The range of allowable address is 1 to 247 3 1 3 Communication Parameter Selection Pressing Down key will advance to the New Change address value edit mode Pressing the Up key will confirm the present value as Address and advance to Baud Rate selection section3 1 3 2 ON O P1 O P2 COM Zimmer PRO V ON O P1 O P2 COM Zimmer PRO V ON O P1 O P2 COM Zim...

Page 5: ...essing the Down key will scroll the value of the second digit from 0 through to 9 the value will wrap from 9 round to 0 Pressing the Up key will advance the operation to the next digit and set the second digit in this case to 5 Denotes that digit will be flashing Enter New Change End value of Input second digit entered prompting for third digit Denotes that digit will be flashing Pressing the Down...

Page 6: ...pting New Change Elbow value of the Input Pressing the Down key will scroll the value of the second digit from 0 through to 7 the value will wrap from 7 round to 0 depending on set value of End value of Input Pressing the Up key will advance the operation to the next digit and set the first digit in this case to 4 third digit Denotes that digit will be flashing Pressing the Down key will scroll th...

Page 7: ...set the End value of Output 1 considerd as DC Current New Change value of the Output 1 Start Pressing the Down key will not affect the first digit It always remains 0 Pressing the Up key will advance the operation to the next digit and set the first digit in this case to 0 Enter New Change value of the Output 1 second digit entered Start prompting for second digit Denotes that digit will be flashi...

Page 8: ...2 1 End value of output 2 Enter New Change End value of the Output 2 second digit entered Enter New Change End value of the Output 2 first digit entered ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 The End value of Voltage Output...

Page 9: ...of the first digit from 0 through to 1 the value will wrap from 1 round to 0 depending the set End value of Output Pressing the Up key will advance the operation to the next digit and set the first digit in this case to 0 prompting for second digit Denotes that digit will be flashing Pressing the Down key will scroll the value of the second digit from 0 through to 9 the value will wrap from 9 roun...

Page 10: ...move the Back cover of transducer by using screw driver Insert screw driver in a snap fitting slot and press in direction of arrow remove all snap fitting pillars of back cover NOTE Black portion in above diagram indicate switch position 1234 ON 1234 ON load independent current load independent voltage DIP switches T ype of output signal Type of Output Signal DIP Switch Setting Insert screw driver...

Page 11: ...5 ModBus Zimmer PRO V supports MODBUS RS485 RTU protocol 2 wire Connection should be made using twisted pair shielded cable All A and B connections are daisy chained together The screens should also be connected to the Gnd terminal To avoid the possibility of loop currents an Earth connection should be made at one point on the network Loop ring topology does not require any termination load Line t...

Page 12: ...o set the Analog O P Type 1 as Voltage Current Voltage 1 Current 2 40029 Sim_Output B 40035 Analog O P Type 2 This address is used to set the Analog O P Type 2 as Voltage Current Voltage 1 Current 2 Example Writing Device address Device address Start address 0E Hex Number of registers 02 Query Change Device address to 2 Byte Count Total number of data bytes received Data register 1 High Byte Most ...

Page 13: ...in the limits of the chosen auxiliary voltage 5 5 Fusing It is recommended that all voltage lines are fitted with 1 amp HRC fuses 5 6 Earth Ground Connections For safety reasons CT secondary connections should be grounded in accordance with local regulations Table 4 RS 485 Set up Code Note Codes not listed in the table above may give rise to unpredictable results including loss of communication Ex...

Page 14: ...perature 23 C 1 C Pre conditioning 30 min acc to IEC EN 60688 Input Variable Rated Voltage Rated Current Input waveform Sinusoidal Form Factor 1 1107 Input signal frequency 50 60Hz Auxiliary supply voltage Rated Value 1 Auxiliary supply frequency Rated Value 1 Output Load Rn 7 5 V Y2 1 With DC current output signal Rn Y2 1 mA 1 With DC Voltage output signal Miscellaneous Acc to IEC EN 60688 Additi...

Page 15: ... surface Installation Data Mechanical Housing Lexan 940 polycarbonate Flammability Class V 0 acc To UL 94 self extinguishing non dripping free of halogen Mounting position Rail mounting wall mounting Weight Approx 0 4kg Connection Terminal Connection Element Conventional Screw type terminal with indirect wire pressure Permissible cross section of the connection lead 4 0 mm single wire or 2 x 2 5 m...

Page 16: ...www zimmer instruments com 16 16 NOTES ...

Reviews: