background image

 

 

ZIEHL  industrie 

–  elektronik  GmbH  +  Co  KG 

Daimlerstr.13,  74523  Schwäbisch  Hall,  Germany 
+ 49 791 504-0,    [email protected],    www.ziehl.de 

 
 

 

Temperature Relays and MINIKA® 

Mains Monitoring 

Digital Panelmeters MINIPAN® 

Switching Relays and Controls 

Measuring Transducers 

Grid- and Plant Protection 

 

Operating Manual MU100W

 

updated: 2018-11-09 / sm 

 

 

 

 

MU100W 

12100-0703-00 

Page

 

1 / 6 

www.ziehl.de 

- Measuring- Transducer for Potentiometers 

 
 

 

 
 

   

 

 

 

Summary of Contents for MU100W

Page 1: ...iehl de www ziehl de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching Relays and Controls Measuring Transducers Grid and Plant Protection Operating Manual MU100W updated 2018 11 09 sm MU100W 12100 0703 00 Page 1 6 www ziehl de Measuring Transducer for Potentiometers ...

Page 2: ...7 4 Current voltage output 4 7 5 Factory setting 4 8 Technical data 5 9 Housing Type V2 6 1 Display and controls 2 Application and short description The MU100W measuring transducer converts the position of a potentiometer into a linear signal 0 4 20 mA respectively 0 10 V Zero can be easily scaled 0 40 Full scale 60 100 of the range of the potentiometers by pressing a button The built in universal...

Page 3: ...close proximity of apparatus with elevated surface temperature or hindrance of the cooling air the tolerable environmental temperature is diminishing To use the equipment flawless and safe transport and store properly install and start professionally and operate as directed Only let persons work with the equipment who are familiar with installation start and use and who have appropriate qualificat...

Page 4: ...arameterization mode press the button Zero for 10s when applying the control voltage until the power LED starts to flash To exit parameterization mode prematurely press the Full scale and zero buttons at the same time The parameterization mode is automatically exited after 10 minutes The set values remain stored even when the control voltage is switched off 7 2 Adjustment zero point 0 40 of the ad...

Page 5: ...00 V Overvoltage category II reinforced insulation Pollution degree 2 Rated insulation voltage Ui 250 V On period 100 EMC tests Emission EN 61000 6 3 Immunity EN 61000 6 2 Installation conditions Permissible ambient temperature 20 C 60 C Permissible storage temperature 20 C 70 C Installation height 2000 m over N N Climatic conditions 5 85 rel humidity no condensation Permissible wiring temperature...

Page 6: ...l base 3 Riegel bar for snap mounting 4 Plombenlasche latch for sealing 5 Frontplatteneinsatz front panel 6 Kennzeichen für unten position downward 7 Riegel bei Wandbefestigung mit Schrauben Riegelbohrung Ø 4 2 mm for fixing to wall with screws Ø 4 2 48 58 45 3 61 8 16 5 90 Option 98 116 35 3 4 1 2 5 7 6 ...

Reviews: