background image

 

 

 

 

 

 

PULL LINE BLOWER

 

OPERATING INSTRUCTIONS 

 

Summary of Contents for EZ.300

Page 1: ...PULL LINE BLOWER OPERATING INSTRUCTIONS...

Page 2: ...Dear Customer Thank you for choosing a quality engineered ZEITLER product Our machines are built using modern production techniques and comprehensive quality assurance Every effort has been made to en...

Page 3: ...uction Mode with EZ300 15 10 Fuel 16 11 Fueling 17 12 Starting Stopping the Engine 18 13 Cleaning the Air Filter 20 14 Adjusting the Carburetor 20 15 Checking the Spark Plug 22 16 Engine Running Behav...

Page 4: ...mals should not be allowed in the area where a power tool is in use When the machine is not in use shut it off and place it so that it does not endanger others Secure it against unauthorized use The p...

Page 5: ...ing must be sturdy but allow complete freedom of movement Wear snug fitting clothing an overall and jacket combination do not wear a work coat Avoid any clothing scarves neckties jewellery or anything...

Page 6: ...t for obstacles such as tree stumps roots and ditches which could cause you to trip or stumble Never work on a ladder or any other insecure support Be particularly alert and cautious when wearing hear...

Page 7: ...y ZEITLER AG These parts are specifically designed to match your machine model and meet your performance requirements and also to avoid the risk of accidents and damage to the machine If you have any...

Page 8: ...00088 1 x Suction connection Art 100073 1 1 x Special equipment for small int from 25 to 50 mm consisting of special black adapter plus special nozzle Art 100105 1 x Head piece 140 with pull line supp...

Page 9: ...Art 100075 1 x Cone orange with metallic head for int conduit from 50 to 120 mm in case of difficult access or frayed conduit end Art 100056 1 x Box with shuttle assembly material 20 x screw with hol...

Page 10: ...100 mm Art 100129 Tubulure 70 to foam body for int of conduits 120 to 200 mm For details see ADDENDUM DISKS AND AXLES www zeitler swiss Art 100309 Parachute for conduits int 30 60 mm Art 100154 Parach...

Page 11: ...x 820 m length tensile strength approx 24 kg box of 10 rolls Art 100136 Pull line rolls 4 mm 1100 m length tensile strength approx 210 kg box of 3 rolls Art 100717 Pull line toneable with copper wire...

Page 12: ...mm Operating Manual EZ300 Version 05 2021 page 12 30 6 Shuttle Assembling Assemble at each end of axle 2 washers 1 disk black or white 1 screw with hole Tighten with the two open end wrenches NEVER U...

Page 13: ...ccupied conduits might be fed with pull line using an appropriate parachute Parachute yellow for int conduit of 30 to 60 mm Parachute green for int conduit of 60 to 100 mm Parachute blue for int condu...

Page 14: ...hing or body 19 As soon as the shuttle has reached the end of the conduit the pull line stops uncoiling if the shuttle pauses pull back by hand and try from the opposite side or with alternative acces...

Page 15: ...ress EZ300 head piece tightly to the conduit 14 Vacuum shuttle without interruption beware of dust 15 Never block conduit with clothing or body 16 Never block air intake grill of the EZ300 with clothi...

Page 16: ...ne sealing rings hoses and the fuel tank Gasoline Use only high quality brand name gasoline with a minimum octane rating of 90 leaded or unleaded Engine Oil Use only quality two stroke engine oil We r...

Page 17: ...from time to time Dispose of remaining fuel and cleaning fluid properly in accordance with local regulations and environmental requirements 11 Fueling Preparations Before fueling clean the filler cap...

Page 18: ...east five times even if the bulb is filled with fuel Adjusting the setting lever To start move the setting lever to the run position I The setting lever selects and holds any throttle position between...

Page 19: ...er rope can rewind properly Other hints on starting If the engine stops when choke knob is on or during acceleration Move the choke knob to and continue cranking until the engine runs If the engine do...

Page 20: ...th compressed air do not wash Replace damaged parts Installing the filter Fit the filter in the filter housing and push the retainer into position Refit the filter cover and turn the filter cover lock...

Page 21: ...ly counterclockwise richer no further than stop Adjusting Idle Speed It is usually necessary to change the setting of the idle speed screw LA after every correction to the low speed screw L Engine sto...

Page 22: ...Rectify the problems which have caused fouling of the spark plug Possible causes are Too much oil in fuel mix Dirty air filter Unfavorable running conditions Fit a new spark plug after about 100 oper...

Page 23: ...OFF THE ENGINE Transporting in a vehicle Allow the tool to cool down before placing it in the original plastic case Properly secure the plastic case to prevent turnover fuel spillage and damage Storin...

Page 24: ...or daily after each refuelling stop monthly every 12 months if problem if damaged if required Complete machine Visual inspection condition leaks x x Clean x Control handle Check operation x x Air fil...

Page 25: ...e and Care must be performed on a regular basis If these maintenance operations cannot be performed by the owner they should be performed by a servicing dealer ZEITLER AG recommends that you have serv...

Page 26: ...ed to blow from opposite Oyes Ono Duct occupied Oyes Ono How far did you blow the pull line __________ m Is the duct diameter identical along the way Oyes Ono More useful information _________________...

Page 27: ...EZ300 Version 05 2021 page 27 30 22 Main Parts EZ300 Control handle Throttle trigger Intake screen Setting lever Spark plug boot Starter grip Carburetor adjusting screw Fuel pump Choke knob Filter cov...

Page 28: ...fuel pump Fuel tank capacity 0 44 l Maximum air flow rate Blowing mode 810 m h Suction mode 770 m h Air Velocity Round nozzle 200mm 7 m s Round nozzle 150mm 13 m s Round nozzle 100mm 29 m s Round noz...

Page 29: ...e to the non observance of the Operating Instructions improper use anomalous environmental conditions incorrect operating conditions overloading or a lack of proper maintenance and care Device defects...

Page 30: ...ZEITLER AG Model EZ300 Displacement 27 2 cm3 is conform to the specification of Directives 98 37 EC 89 336 EEC and 2000 14 EC The product has been developed and manufactured in compliance with the fol...