background image

 
 
 
 

 

 

 

 

 

 

VIPA System 300S 

 
 
 
 
 
 
 
 

SPEED7 - PS | 307-1FB70 | Manual 

HB140E_PS | RE_307-1FB70 | Rev. 13/43 

October 2013 

 

 
 
 
 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for VIPA 307-1FB70

Page 1: ...VIPA System 300S SPEED7 PS 307 1FB70 Manual HB140E_PS RE_307 1FB70 Rev 13 43 October 2013 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...dicated by the CE marking affixed to the product Conformity Information For more information regarding CE marking and Declaration of Conformity DoC please contact your local VIPA customer service organization Trademarks VIPA SLIO System 100V System 200V System 300V System 300S System 400V System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft für Visualisierung und Prozes...

Page 3: ...missioning and operation About this manual 1 Safety information 2 Chapter 1 Assembly and installation guidelines 1 1 Overview 1 2 Installation dimensions 1 3 Assembly SPEED Bus 1 4 Cabling 1 7 Installation guidelines 1 8 General data 1 11 Chapter 2 Hardware description and deployment 2 1 Safety Information for Users 2 2 Properties 2 3 Structure 2 4 Technical data 2 5 All manuals and user guides at...

Page 4: ...Contents Manual VIPA System 300S SPEED7 2 HB140E PS RE_307 1FB70 Rev 13 43 All manuals and user guides at all guides com ...

Page 5: ...s a self contained description of a specific topic The following guides are available in the manual an overall table of contents at the beginning of the manual an overview of the topics for every chapter an index at the end of the manual The manual is available in printed form on paper in electronic form as PDF file Adobe Acrobat Reader Important passages in the text are highlighted by following i...

Page 6: ...anual must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before using or commissioning the components described in this manual Modification to the process control system should only be carried out when the system has been disconnected from power Installation and modifications only by properly trai...

Page 7: ...ind all information required for the installation and the cabling of a PLC system with the components of the System 300 and the Co Power Supply Topic Page Chapter 1 Assembly and installation guidelines 1 1 Overview 1 2 Installation dimensions 1 3 Assembly SPEED Bus 1 4 Cabling 1 7 Installation guidelines 1 8 General data 1 11 Overview Content All manuals and user guides at all guides com ...

Page 8: ... Before installing the modules you have to clip the backplane bus connector to the module from the backside A backplane bus connector is scope of delivery of a peripheral module With SPEED Bus the bus connection happens via a SPEED Bus rail integrated in the profile rail at the left side of the CPU Due to the parallel SPEED Bus not all slots must be occupied in sequence At SLOT 1 DCDC you may plug...

Page 9: ...ion guidelines HB140E PS RE_307 1FB70 Rev 13 43 1 3 Installation dimensions 1tier width WxHxD in mm 40 x 125 x 120 65mm 40mm 122 mm 125 mm 125mm 120mm 175mm Dimensions basic enclosure Dimensions Installation dimensions All manuals and user guides at all guides com ...

Page 10: ... profile rail Please look for a low impedance connection between profile rail and background Connect the profile rail with the protected earth conductor The minimum cross section of the cable to the protected earth conductor has to be 10mm 2 Order number SPEED Bus Slot A B C VIPA 390 1AB60 160mm 140mm 10mm VIPA 390 1AE80 482mm 466mm 8 3mm VIPA 390 1AF30 530mm 500mm 15mm VIPA 390 1AJ30 830mm 800mm ...

Page 11: ... the power supply by screwing SLOT1 DCDC CPU SLOT2 Modules PS 307S_Co To connect the SPEED Bus modules plug it between the triangular positioning helps to a plug in location marked with SLOT and pull it down Only the SLOT1 DCDC allows you to plug in either a SPEED Bus module or the Co Power Supply PS 307S_Co exclusive together with the CPU 317S Fix the modules by screwing SLOT1 DCDC CPU SLOT2 To d...

Page 12: ...ing SLOT1 DCDC CPU SLOT2 Repeat this procedure with the peripheral modules by clicking a backplane bus coupler stick the module right from the modules you ve already fixed click it downwards and connect it with the backplane bus coupler of the last module and bolt it Danger Before installing or overhauling the System 300V the power supplies must be disconnected from voltage pull the plug or remove...

Page 13: ... can use flexible wires without end case as well as stiff wires You fix the conductors to the CageClamps like this 1 2 1 Rectangular opening for screwdriver 2 Round opening for wires The picture on the left side shows the cabling step by step from top view 1 2 3 To conduct a wire you plug a fitting screwdriver obliquely into the rectangular opening like shown in the picture To open the contact spr...

Page 14: ...nt All System 300 components are developed for the deployment in hard industrial environments and fulfill high demands on the EMC Nevertheless you should project an EMC planning before installing the components and take conceivable interference causes into account Electromagnetic interferences may interfere your control via different ways Electromagnetic fields RF coupling Magnetic fields with pow...

Page 15: ... see below Analog lines must be laid isolated When transmitting signals with small amplitudes the one sided laying of the isolation may be favorable Lay the line isolation extensively on an isolation protected earth con ductor rail directly after the cabinet entry and fix the isolation with cable clamps Make sure that the isolation protected earth conductor rail is connected impedance low with the...

Page 16: ...u only achieve the absorption of the lower frequencies A one sided isolation connection may be convenient if the conduction of a potential compensating line is not possible analog signals some mV res µA are transferred foil isolations static isolations are used With data lines always use metallic or metalized plugs for serial couplings Fix the isolation of the data line at the plug rack Do not lay...

Page 17: ...31 2 0 60 C Vertical installation EN 61131 2 0 60 C Air humidity EN 60068 2 30 RH1 without condensation rel humidity 10 95 Pollution EN 61131 2 Degree of pollution 2 Mechanical Oscillation EN 60068 2 6 1g 9Hz 150Hz Shock EN 60068 2 27 15g 11ms Mounting conditions Mounting place In the control cabinet Mounting position Horizontal and vertical EMC Standard Comment Emitted interference EN 61000 6 4 C...

Page 18: ...Chapter 1 Assembly and installation guidelines Manual VIPA System 300S SPEED7 1 12 HB140E PS RE_307 1FB70 Rev 13 43 All manuals and user guides at all guides com ...

Page 19: ...ere the hardware structure and the deployment of the Co Power Supply together with the CPU 317S is described The technical data are at the end of the chapter Topic Page Chapter 2 Hardware description and deployment 2 1 Safety Information for Users 2 2 Properties 2 3 Structure 2 4 Technical data 2 5 Overview Content All manuals and user guides at all guides com ...

Page 20: ...dules damaged in this way are normally not immediately recognized The according error may occur only after a while of operation Modules that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices and meticulous attention to the applicable rules and regulations for ...

Page 21: ...wer Supply may only be operated together with the CPU 317S As soon as the CPU 317S is power supplied the Co Power Supply starts automatically Operates exclusive together with the CPU 317S Output current 5 5A extends the maximum total value at the backplane bus Standard bus SPEED Bus Automatic start up with the power supply of the CPU 317S Defined power down at failure of one of the power supplies ...

Page 22: ... Error Co Power Supply inactive On If missing power supply of the CPU 317S if wrong slot respectively if not mounted at SPEED Bus As soon as the DC 24V input voltage is present at CPU 317S and Co Power Supply the output voltage to the backplane bus is issued Here the output current at the backplane bus standard bus SPEED Bus is increased by 5 5A If the input voltage is missing at one power supply ...

Page 23: ...llel switchable Protect type short circuit electr overload over temperature IP20 Ripple of output voltage max BW 20 MHz 150 mV Efficiency typ 90 Power loss typ 6 W Status information alarms diagnostics Status display yes Interrupts no Process alarm no Diagnostic interrupt no Diagnostic functions no Diagnostics information read out none Supply voltage display green LED Group error display red LED C...

Page 24: ...Chapter 2 Hardware description and deployment Manual VIPA System 300S SPEED7 2 6 HB140E PS RE_307 1FB70 Rev 13 43 All manuals and user guides at all guides com ...

Reviews: