background image

 

E

 

PM1D Manager for Windows

 

Operating manual

Summary of Contents for PM1D Manager V2

Page 1: ...E PM1D Manager for Windows Operating manual ...

Page 2: ...DI Driver 17 Windows 98 98SE 17 Windows Me 18 Windows 2000 18 Windows XP 19 Troubleshooting 19 About the specifications of this software Specifications of this software and the material given in this manual are subject to change without notice Copyright Copying or distributing this software and or this manual in part or in whole using any method without the written permission of Yamaha Corporation...

Page 3: ...n the console switches encoders are enclosed in square brackets in order to distinguish them from the knobs and buttons that are displayed by the software Example This is the same function as the DIRECT RECALL 1 12 switches in the SCENE MEM ORY block of the console Various icons The left icon is used to indicate tips and ref erence pages Particularly important items or operations you must use with...

Page 4: ...WIN folder double click the Setup icon The opening screen of the installer will appear Depending on your PC system you may be asked to restart the system during the installation process If so installation will continue automatically after you restart 3 As directed by the instructions on the screen click the Next button as needed to proceed to the next step 4 When the Select Installation Folder scr...

Page 5: ...When the Control Panel opens double click the Add or remove applications icon 3 Select the PM1D Manager item and click Add or remove PM1D Manager and related files will be deleted from the hard disk For details on the procedure refer to your Windows manual Using Setup exe 1 Perform steps 1 3 of Installing PM1D Manager A screen will appear asking you to select either Repair PM1D Manager or Remove P...

Page 6: ... displayed Exiting You can use any of the following methods to exit PM1D Manager 1 In the lower left of the Function menu screen click the EXIT button 2 Open the File menu and select Exit 3 Click the Close button of the window 4 Select Close from the PM1D Manager button in the task bar 5 Press Alt F4 from the keyboard A popup window will ask you to confirm that you want to exit To exit the applica...

Page 7: ...current settings of the PM1D Manager as well as the scene memories and the various libraries will be initialized to the factory set condition If you click the Initialize Current Memories but ton The current settings of the PM1D Manager will be initialized However scene memories and the various libraries will not be affected When you press either of these buttons a dialog box will appear asking you...

Page 8: ... Communication Setup Lower part of the display common to all screens 1 RECALL button MUTE button Select the function of the DIRECT RECALL MUTE MASTER 1 12 buttons 2 from the following two choices DIRECT RECALL You can use the DIRECT RECALL MUTE MAS TER 1 12 buttons to directly recall the scenes assigned to direct recall numbers 1 12 For details on how to assign a scene to a direct recall number re...

Page 9: ...hey were immediately following instal lation Each button has the following function Initialize All Memories button When you click this button the current settings of the PM1D Manager as well as the scene memo ries and the various libraries will all be initialized to the factory set condition Initialize Current Memories button When you click this button the current settings of the PM1D Manager will...

Page 10: ...ed and terminated System connection examples Example 1 Standard mode connect the PC to the console Console 1 Engine 1 Example 2 Standard mode connect the PC to the engine Example 3 Mirror mode connect the PC to the console Console 1 Engine 2 mirror mode Example 4 Mirror mode connect the PC to the engine Console 1 Engine 2 mirror mode The PC can only be connected to the engine that is selected in M...

Page 11: ...console 2 it cannot be used System example 7 Cascade connection You can connect and use either PC1 or PC2 not both and PC3 or PC4 not both Even if there is no console just an engine and PC can be used as a system Console1 CS1D PC1 Engine DSP1D Console2 CS1D PC2 PC1 Engine DSP1D PC2 Engine DSP1D PC3 PC4 cascade Console CS1D Console CS1D DSP1D ENGINE Master system Slave system ...

Page 12: ...ft of the Function menu screen or the OPTION menu in the menu bar 4 In the Communication Port field select the port that you will be using and click the OK button 5 If the system includes a console click the PERMIT button in the PC CONNECTION area of the con sole s SYSTEM CONNECTION screen This will allow a PC connection with the connected console engine For details refer to CS1D Reference Manual ...

Page 13: ...n mode please check the following points In the console s SYS W CLOCK screen PC CON NECTION area make sure that the PERMIT but ton of the device connected to the PC is turned on Make sure that no popup window is displayed in the screen of the console Make sure that no file is being loaded on the con sole Make sure that time code is not running in the system Auto fading or manual fading are not in ...

Page 14: ...e user cancels during an upload or download When the SYSTEM CONFIGURATION of the console is switched to console 2 while the console and PC are still online In these cases PM1D Manager will attempt to return all data on the PC to the recovery point but it is possi ble that the data has already been destroyed You can either reload the data or re connect to the device with which you were communicatin...

Page 15: ...curs MIDI program changes control changes The MIDI ports of the PC cannot be used as MIDI inputs outputs for the PM1D Manager software TC events The setting can always be made but since operation in response to incoming time code is performed by the console itself the following restrictions apply It will not be possible to operate the EVENT RECALL ING button or TIME CODE IN button in the TC EVENT ...

Page 16: ... cation software such as PM1DLOAD PM1D Manager cannot be used simultaneously on the same port as other serial communication soft ware such as PM1DLOAD Please exit all such software before starting PM1D Manager Simultaneous use with software that uses the YAMAHA USB MIDI driver Windows 98 98SE Me Software such as sequencers that uses the MIDI port cannot be used simultaneously on the same port with...

Page 17: ... in the PC CONTROL section of the rear panel 3 Turn on the console engine The Add New Hardware Wizard appears If it doesn t appear try disconnecting and reconnecting the USB cable Alternatively open the Add New Hardware control panel 4 Click Next The following window appears 5 Select Search for the best driver for your device Recommended and then click Next The following window appears 6 Select Sp...

Page 18: ... Click Finish and then restart your PC Windows 2000 1 Start your PC and Windows log on as the Adminis trator and then insert the included CD ROM into your PC s CD ROM drive 2 Go to My Computer Control Panel System Hardware Driver Signing File Signa ture Verification select Ignore Install all files regardless of file signature and then click OK 3 Power off the console engine and use a USB cable to ...

Page 19: ...tem control panel click the Device Manager tab and check for any crosses x or exclamation marks next to the Universal Serial Bus controllers and USB Root Hub items If these items do have these marks next to them your USB controller is disabled For information on enabling your USB controller refer to your PC s documenta tion Windows If for some reason installation of the Yamaha USB Driver fails the...

Page 20: ...IP 20 M D G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2002 Yamaha Corporation Printed in Japan ...

Reviews: