background image

Summary of Contents for FP 1023

Page 1: ...ID S 1 0 I D 0 m i t_ j 0 OJ tD 00 c d n 0 3 c 0 ft c 113 c l D l j m C 0 2 c 3 Di 3 z 8 Q rJJ c I d 0 N w ...

Page 2: ... any maintenance or cleaning Turning off controls will not reduce this risk 3 An extension cord should not be used unless absolutely necessary If an extension cord must be used make sure that the pins on the plug are the same number size and shape as those of the original power supply plug 4 Place the unit in an area that will allow air to flow freely around the unit DO NOT block or obstruct vent ...

Page 3: ... voltage is 120 VAC If the input voltage is 230 VAC an internal jumper setting will be required see page 4 NOTE The DC output connector RED BLACK has a tubular hole of dia 0 2 5mm with a set screw For a firm connection crimp solder a pin type copper terminal on the cable ends of your 12V DC device Ensure that the power supply s ON OFF switch is off and it is unplugged from the AC outlet Switch off...

Page 4: ...ected to 230 VAC Suggested Remedy Check voltage setting before powering the unit Unit is defective echnical support I SECTION 6 I Troubleshooting PROBLEM THE OUTPUT VOLTAGE IS OV OR VERY LOW Probable Cause Input voltage is very low or the unit has been set for 230 VAC input but has been connected to 120 VAC The unit is in current limit condition due to overload caused by large reactive load ing or...

Page 5: ...ly A slowly moving slightly buzzing carrier heard in the receiver may be caused by the antenna being too close As with the transmitter related noise pick up a loose coaxial connector or a broken or a miss ing ground may aggravate this problem Normally these noises will be below the background or band noise Increase the separation between the power supply and the receiving antenna Use an outdoor an...

Page 6: ...tive terminal and leave the other end free The wave length corresponds to the wave length of the interfering frequency May not be practical for long wave lengths Formula Wave length Meters 300 I frequency in MHz SECTION 9 I Specifications INPUT VOLTAGE nominal 120 VA 6offzJPre Set i30 VAC 50 Mf Requires Internal Jumper Setting See Page 4 OUTPVT VOLTAGE 13 SVDC f OUTPUT RIPPLE NOISE 150 Mv Peak TEi...

Reviews: