Synchronising Xsens Systems with 

Noraxon TeleMyo

 

 

Step 

 by 

 step manual 

16 

 01 

 2020 

© 2005-2020, Xsens Technologies B.V. All rights reserved. Information in this document is subject to change 

without notice. Xsens, MVN, MotionGrid, MTi, MTi-G, MTx, MTw, Awinda and KiC are registered trademarks 

or trademarks of Xsens Technologies B.V. and/or its parent, subsidiaries and/or affiliates in The Netherlands, 

the USA and/or other countries. All other trademarks are the property of their respective owners. 

 

Summary of Contents for Awinda Station

Page 1: ...ion in this document is subject to change without notice Xsens MVN MotionGrid MTi MTi G MTx MTw Awinda and KiC are registered trademarks or trademarks of Xsens Technologies B V and or its parent subsi...

Page 2: ...xon TeleMyo slave 6 4 1 Start and Stop a recording 6 4 1 1 Hardware connections 6 4 1 2 Software Setup Noraxon MyoResearch 6 4 1 3 Xsens Software 8 5 Noraxon TeleMyo as Master and MVN Analyze as slave...

Page 3: ...m the Master software to start recording 4 Start the recording on the Master software Then both systems will start recording at the same time 5 Stop recording on the master software Then both systems...

Page 4: ...re Wireless EMG transmitters 1 TeleMyo DTS plus antenna 1 TeleMyo mini receiver to use Noraxon as Master MVN Awinda or MVN Link Awinda station BNC BNC cables Figure 2 Awinda Station 4 BNC ports SYNC I...

Page 5: ...can detect polarity changes on the input lines When a trigger is detected on one of the input lines the Awinda or Sync Station can be configured to perform a specific action 3 2 Sync OUT Sync OUT ena...

Page 6: ...rode or sensor site to a belt worn receiver The TeleMyo 2400R G2 Mini Receiver is an optional accessory item for the portable TeleMyo 2400T G2 Transmitter System It is TTL compatible facilitating sync...

Page 7: ...is gait analysis measuring the medial gastrocnemius tibialis anterior semitendinosus and the rectus femoris For an 8 Channel EMG system Channel 9 is selected as the synchronisation line in the Noraxon...

Page 8: ...e The Noraxon software initialises the EMG signals When this screen is reached click record on the bottom left hand side of the screen on the Noraxon software Figure 7 Noraxon system ready to begin re...

Page 9: ...following settings 1 In the Configuration window in the Sync tab you should select Strat recording out Stop Recording out Out 1 Polarity Rising Edge Skip Factor 0 Skip First 0 Pulse width 10ms Trigge...

Page 10: ...T port of TeleMyo mini receiver to BNC connection Sync IN 1 of Awinda Station Manual trigger pulse jack connector to Sync IN port of TeleMyo mini receiver Connect the external antenna to the TeleMyo D...

Page 11: ...y Rising Edge Skip Factor 1 Skip First 0 Delay 0 ms Trigger once uncheck In 1 Polarity Rising Edge Skip Factor 1 Skip First 1 Delay 0ms Trigger once uncheck To initialize recording click the record bu...

Page 12: ...te of 120Hz you will realise that the maximum frame rate that the output signal will have is 120Hz Practically this entails that every other frame of Xsens will be synchronize with the frame of the ot...