background image

1

Service Manual – ThermoPro Twin & Single Brewers

FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW.WILBURCURTIS.COM

Important Safeguards

This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be 

performed by an authorized Wilbur Curtis service technician.

  • DO NOT immerse the unit in water or any other liquid
  • To reduce the risk of fire or electric shock, DO NOT open service panels. No user serviceable parts inside.
  • Keep hands and other items away from hot surfaces of unit during operation.
  • Never clean with scouring powders, bleach or harsh chemicals.

Symbols

WARNINGS – To help avoid personal injury

Important Notes/Cautions – from the factory

Sanitation Requirements

This Curtis Generation 3 Unit is Factory Pre-Set and Ready to Go… Right from the Carton.

Following are the Factory Settings for your G3 Coffee Brewing Systems:

 

• Brew Temperature = 200°F 

 

 

• Water Bypass = On for LARGE & MEDIUM Brew Only

 

• Brew Volume = Set to Vessel Requirement. 

• Sleep Mode = Off

System Requirements:
 

• Water Source   20 – 90 PSI (Minimum Flow Rate of 1 GPM)

 

• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model. 

 

WILBUR CURTIS COMPANY 

 

 

Montebello, CA 90640

Models Included
  TP2T – ThermoPro Twin
  TP2S – ThermoPro Single

CAUTION: DO NOT 

connect this brewer to hot 

water. The inlet valve is 

not rated for hot water.

CAUTION: Please use 

this setup procedure 

before attempting to use 

this brewer. Failure to follow the 

instructions can result in injury or the 

voiding of the warranty.

ISO 9001 REGISTERED

WARNING

 HOT LIQUID, 

Scalding may occur. 

Avoid splashing. 

IMPORTANT: Equipment 

to be installed to comply 

with applicable federal, 

state, or local plumbing/electrical 

codes having jurisdiction.

NSF International requires the following water connection:

1.  A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can 

be moved for cleaning underneath the unit.

2.  This equipment is to be installed with adequate back flow protection to comply with applicable federal, 

state and local codes.

3.  Water pipe connections and fixtures directly connected to a potable water supply shall be sized, 

installed and maintained in accordance with federal, state, and local codes.

Setup Steps

The unit should be located on a solid counter top and leveled (left to right and front to back).  Connect a water line from 

the water filter to the brewer. 
NOTE: A water filtration system must be installed to maintain a trouble-free operation. (In areas with extremely hard water, 

we suggest that a sedimentary and taste & odor filter be installed.) This will prolong the life of your brewing system and 

enhance coffee quality.  

W

ilbur

 C

urtis

 C

ompany

, i

nC

.

1.   A 3/8”Flare x 3/8” Male pipe elbow is supplied with the brewer for water line connection. Use tubing sized sufficiently to 

provide a minimum of 1.0 GPM.

2.   Connect the unit to an appropriate electrical power circuit.
3.   Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to fill.  When the water level in the 

tank rises to the correct volume, the heating elements will energize automatically.

4.   The heating tank will require 20 to 30 minutes to reach operating temperature (200°F), indicated when READY TO 

BREW is displayed on the LCD screen.

5.   Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.
6.   Brew a cycle of at least 12 ounces, to purge the water lines of any air that may be trapped after filling.
7.   Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.
8.   Brew a cycle of at least 12 ounces, to purge the water lines of any air that may be trapped after filling.
9.  The ThermoPro brewer is now ready for operation.

Содержание ThermoPro Single

Страница 1: ...ernational requires the following water connection 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit so that the machine can be moved for cleaning underneath the unit...

Страница 2: ...eaches the setpoint 200 F unit is at brewing temperature THERMOPRO WILBUR CURTIS WILBUR CURTIS WILBUR CURTIS FILLING WILBUR CURTIS HEATING WILBUR CURTIS READY TO BREW 2 BREWING INSTRUCTIONS 1 Brewer s...

Страница 3: ...ramming selections are performed with the three center buttons The symbols below the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT IMPORTANT NOTE ThermoPro Programming...

Страница 4: ...E 27 A 25 26 1 2 34 3 4 5 6 7 8 13 14 15 16 9 10 11 12 17 18 19 20 21 22 23 24 28 29 30 31 B 33 4 PARTS DIAGRAM THERMOPRO TWIN BREWER TP2T...

Страница 5: ...NTER WRAP TP 90 VALVE WATER INLET 2GPM 120V 10W ELBOW 3 8 FL x 3 8 NPT PLATED KIT DUMP VALVE BREW RIGHT SOLENOID LOCK BREW CONE RIGHT LEFT 120V SOLENOID LOCK BREWCONE LEFT OLDER UNITS FAUCET ASSEMBLY...

Страница 6: ...6 PARTS DIAGRAM THERMOPRO SINGLE BREWER TP2S 26 3 12 2 6 28...

Страница 7: ...W COVER CENTER WRAP VALVE WATER INLET 2GPM 120V 10W FUSE HOLDER W 5A FUSE KIT DUMP VALVE BREW RIGHT KIT DUMP VALVE WC 820WC 821 WC 844 FAUCET ASSY HOT WATER TP2S 2T RELAY SOLID STATE 40A W HEAT SINK H...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...an water removing any residual detergent d Dry the area c Attach the sprayhead Cleaning the Thermoserver 1 Drain coffee from the server 2 Fill the liner with a mild detergent solution and let it stand...

Страница 11: ...Page Intentionally Left Blank 11...

Страница 12: ...l and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to e...

Отзывы: