(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. 

Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component. 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit  over  current  protection in 

accordance with the National Electric Code, ANSI/NFPA 70. 

CAUTION!

    Risk of explosion if battery is replaced by an incorrect type. Batteries shall be installed by service personnel, and the replacement of 

batteries with a suitable recommended type. Dispose of used batteries according to the instructions. 

CAUTION!

    Do not dispose of batteries in a fire. The batteries may explode. 

CAUTION!

    Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. 

CAUTION!    DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

ADI  does  not  sell  UPS  products  for  life  support  or  medical 

applications. 

DO  NOT

  use  in  any  circumstance  that  would  affect  operation  and  safety  of  life  support  equipment,  any  medical  applications  or 

patient care. 

CAUTION!    DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation from the aquarium can cause the unit to short out. 

Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75. 

CAUTION!    DO NOT USE THE UPS ON ANY TRANSPORTATION!   

To reduce the risk of fire or electric shock, do not use the unit on any 

transportation such as airplanes or ships.

 

The effect of shock or vibration caused during transit and the damp environment can cause the unit to 

short out. 

 

WARNING!   

This product can expose you to chemicals including Styrene, and Bisphenol-A, which is known to the State of California to 

cause cancer, birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. 
 
 

 

 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

UPS unit, User’s manual, and Telephone cable. 

 

SYSTEM FUNCTION BLOCK DIAGRAM

 

 

 

 

 

 

 

 

 

 

 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

1.  Ensure that the equipment plugged into the 

outlet does not exceed the UPS unit’s rated capacity (350VA/255W for 0E350-V6).    If the rated 

capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.     

2.  There are many factors that can affect the amount of power that your computer system will require.    For optimal system performance keep 

the load below 80% of the unit

’s rated capacity. 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to 

ensure the 

battery’s maximum charge capacity, it is recommended that you charge the battery 

for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is 

plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or 

turned off. 

2.  With the UPS unit turned off and unplugged, connect your equipment requiring battery backup into the battery power supplied outlets.    Plug 

the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets.   

DO NOT plug a laser printer, paper 

shredder, copier, space heater, vacuum, sump pump or other large electrical device into the 

“Battery and Surge Protected Outlets”. 

The power demands of these devices will overload and possibly damage the unit. 

3.  To protect a fax, phone or modem, connect a telephone cable from the wall jack outlet to the IN jack of the UPS.   

Connect a telephone cable from the UPS OUT jack to protect a modem port on the computer, a telephone,   

or fax machine. 

4.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).    Make sure the wall branch outlet is   

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air   

conditioner, 

refrigerator, copier, etc…).    The warranty prohibits the use of extension cords, outlet strips,   

and surge strips. 

5.  Press the power switch to turn the unit on.    The Power On indicator light will illuminate green 

and the unit will “beep” twice. 

6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.    Make sure the circuit breaker is depressed and then turn the UPS on. 

7.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.   

8.  To store the UPS for an extended period, cover it and store with the battery fully charged.    While in storage, recharge the battery every three 

months to ensure battery life. 

9.  For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. 

 

 

 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

① 

Battery and Surge Protected Outlets 

The unit has three battery powered/surge suppression outlets to ensure temporary uninterrupted operation of your equipment during a 

power failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical 

device into the 

“Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage 

the unit.) 

② 

Full-Time Surge Protection Outlets 

The UPS has surge suppression only outlets to provide protection from surges and spikes. 

③ 

Power Switch 

To turn the UPS on, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after a 

short beep. 

To turn the UPS off, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after two 

short beeps. 

Quickly press the POWER button twice can turn off or turn on the audible Alarm. The default setting is for the Alarm On. 

To turn the alarm off, quickly press the power button twice. You will hear two short beeps when the alarm is turned off. 

To turn the alarm back on, quickly press the power button twice. You will hear a short beep when the alarm is turned on. 

*When the alarm is turned off, there will be no audible notification when the UPS reaches a low battery state. 

④ 

Power On Indicator (green) 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. 

⑤ 

Electrical Wiring Fault Indicator (red) 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If 

this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The unit will 

not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

⑥ 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, or telephone line. (RJ11) 

⑦ 

Circuit Breaker 

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.   

⑧ 

Outlets Designed for AC Adapters 

The UPS unit has two widely-spaced outlets, so AC power adapters can be plugged into the UPS without overlapping adjacent outlets. 

 

 

 

 

 

Power ON 

 

Wiring Fault 

 

Alarm 

CONDITION 

On 

Off 

Off 

Normal 

On* 

Off 

Beeps twice   

every 30 seconds 

Utility Failure- 

The UPS is providing power to battery power-supplied 

outlets from its battery. 

On* 

Off 

Rapid Beeping 

every 1/2 second 

Utility Failure-

 The UPS is providing battery power.    Rapid beeping 

indicates the unit will run out of power shortly. 

Off 

Off 

Constant tone 

Overload  -

  Occurs  when  connected  equipment  exceeds  the  listed 

capacity of the UPS.    Turn the UPS off, unplug at least one piece of 

equipment from battery outlets, reset the circuit breaker and turn the 

unit on. 

On/Off 

On 

None 

Electrical Wiring Fault - 

This 

indicates a wiring problem with the 

AC  outlet

  such  as  bad  ground,  missing  ground,  or  reversed  wiring.   

Disconnect  all  electrical  equipment  from  the  outlet  and  have  an 

electrician check the outlet to insure proper wiring. 

Off 

Off 

Constant tone 

Utility  Failure- 

The  frequency  is  beyond  47-63Hz.  The  UPS  will  not 

turn on in line mode.

 

*When it beeps, the power on LED will flash accordingly. 

 

 

 

 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit.

 

Circuit breaker has tripped due to an 
overload. 

Turn the UPS off and unplug at least one piece of 
equipment.    Reset the circuit breaker by depressing the 
button, and then turn the UPS on.

 

The UPS does not perform 
expected runtime. 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is worn out. 

Contact ADI/W Box Technologies US 1-800-233-6261; 
Canada 877-234-7378; PR 787-793-8830 

The UPS will not turn on. 

The on/off switch is designed to 
prevent damage from rapidly turning 
it off and on. 

Turn the UPS off.    Wait 10 seconds and then turn the UPS 
on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 110/120V 50/60Hz outlet. 

The battery is worn out. 

Contact ADI/W Box Technologies US 1-800-233-6261; 
Canada 877-234-7378; PR 787-793-8830 

Mechanical problem. 

Contact ADI/W Box Technologies US 1-800-233-6261; 
Canada 877-234-7378; PR 787-793-8830 

The frequency is beyond 47-63Hz. 

Turn the UPS off. Make sure the frequency range is within 
47-63Hz. Or you can turn on with battery mode. 

 
 
 

 

 
 

 

 

0E-350V6 

User

’s Manual 

K01-1101012-01

 

 

 
 

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

TROUBLESHOOTING 

IMPORTANT SAFETY WARNINGS 

 

EMI Filter 

Surge 

Suppressor 

Charger 

AC/DC 

Battery 

Inverter 

DC/AC 

Input 

Output 

Normal Mode 

Battery Mode 

 

 

 

 

 

Reviews: