manualshive.com logo in svg
background image

WB-800ICH1U-IPVM-8

Quick Start Guide

Содержание WB-800ICH1U-IPVM-8

Страница 1: ...WB 800ICH1U IPVM 8 Quick Start Guide ...

Страница 2: ...ctive earthing connection of the socket outlet is verified by a skilled person Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75 Only use brackets attachments accessories specified by the manufacturer Do not place the device in an unstable position where it might fail and cause injuries This equipment is not suitabl...

Страница 3: ...nts 1 WB 800ICH1U IPVM 8 4 Screw in feet and screws 1 Removable region specific power cord in over pack box not PDU carton 1 IEC sleeve 2 Rack mounting brackets 8 Mounting bracket screws M3 x 6 mm 1 Quick Start Guide ...

Страница 4: ...or each outlet F Reset button Press and release to restart the network card press and hold five seconds to reset network settings and press and hold 10 seconds to restore to factory defaults G Safe Voltage button Toggles the Safe Voltage feature on and off When enabled Safe Voltage turns off outlets to protect connected equipment from out of range input voltage H UPS Link For future use to connect...

Страница 5: ...ed outlet number is powered F Button 1 Sequences through outlets 1 through 8 left to right displaying the Current for the specified outlet Aggregate of all outlets display when clicking past outlet 8 This button is also used to reset individual outlets See How to Manually Reset Individual Outlets from the Faceplate on page 6 G Button 2 Sequences through outlets 8 through 1 right to left displaying...

Страница 6: ...The LED light flashes on the specified outlet for 5 minutes during this time the display windows show the Current for the selected outlet Once the 5 minutes has expired the WattBox defaults back to displaying the aggregate total of the entire unit and all LEDs default back to being illuminated How to Manually Reset Individual Outlets from the Faceplate 1 Tap B1 or B2 to sequence through the outlet...

Страница 7: ...late To reset all of the outlets press and hold B1 and B2 at the same time for 3 seconds The Current display shows a rotating 0 as the outlets reset Note The reset follows the Power On delay set in OvrC Outlets designed as Disabled in OvrC do not reset ...

Страница 8: ...e WattBox Safe Voltage Blue Solid Safe Voltage is enabled and current incoming AC voltage is safe for operation All outlets are receiving power Blue Slow Blink Safe Voltage is enabled but the incoming voltage is not safe Off Safe Voltage is disabled Surge Protected Blue Solid The WattBox is powered on and outlets are protected Off The WattBox is not powered on or the MOVs have opened removing powe...

Страница 9: ...WB 800ICH1U IPVM 8 can be mounted in a rack or placed in a cabinet Rack Mounting Attach mounting brackets to the WattBox using the supplied hardware then install the WattBox into the rack using standard rack screws not included ...

Страница 10: ...10 Cabinet Placement Attach supplied feet to the bottom of the WattBox for cabinet placement ...

Страница 11: ...r router or switch into the WB 800I Network port 2 Connect the IEC power cord to the power conditioner and plug into a grounded outlet Mobile Apps Web Browser Access EA AMP HYB 2D 1000 CH SEL PROTECT CH2 ADJUST SET MENU BACK CLIP 10 20 SIGNAL PROTECT CH1 CLIP 10 20 SIGNAL Router WB 800ICH1U IPVM8 ...

Страница 12: ...m To find training for OvrC go to snp1 co ovrc Completing OvrC Setup 1 Ensure the WB 800I is connected to the internet via your router or network switch 2 Log in to your OvrC account 3 Add the WB 800I by entering its MAC address and service tag ST number You can now complete setup through OvrC Ensure your firmware is up to date schedule automatic reboots set up power on delays etc ...

Страница 13: ...ry flipping the switches in the room especially those near the wall outlet Also check the location s circuit breakers Too many devices are connected causing an overload tripping the WattBox s internal circuit breaker Press the circuit breaker reset button Allow 10 minutes before attempting to reset otherwise the reset will fail If the circuit breaker continues to trip move one or more components t...

Страница 14: ...tory default the WattBox In some instances a component plugged into a switched outlet won t automatically power itself up when the WattBox is turned on Manually turn the component on Speakers emit a humming or buzzing noise WattBox is sharing AC power with equipment that is not properly grounded Connect the WattBox to a dedicated outlet Unplug different components from the WattBox one at a time to...

Страница 15: ...0VAC 50 60Hz AC Input Connection IEC 60320 C14 Fuse Rating 10A 250VAC Power Rating 2400W Voltage Protection Rating L N 900 V L E 1 9 kV N E 1 7 Kv Joule Rating 3780J Surge Component Metal Oxide Varistor MOV Protection Modes L N L E N E Peak Impulse Current 135kA Disconnect Circuitry Yes Thermal Fuse Yes EMI RFI Noise Filtration 53dB 1kHz to 1MHz ...

Страница 16: ...16 Outlet Filter 1 bank with 8 outlets Operating Temperature Range 10 C to 40 C 14 F to 104 F Certifications CE AU Dimensions WxHxD 440 mm 17 32 44 mm 1 73 312 mm 12 28 ...

Страница 17: ...17 Dimensions ...

Страница 18: ...tems LLC in the United States and or other countries 4Store 4Sight Control4 Control4 My Home SnapAV and WattBox are also registered trademarks or trademarks of Snap One LLC Other names and brands may be claimed as the property of their respective owners Snap One makes no claim that the information contained herein covers all installation scenarios and contingencies or product use risks Information...

Отзывы: