background image

1

2

3

Total

B1

B2

ACCESSORY OUTLET

(UNPROTECTED)

CURRENT

VOLTAGE

POWER

WB-800I-FP

WB-800I-FP

WattBox® Rack Mountable Faceplate

Display | 220 - 240V

Quick Start Guide

Summary of Contents for WB-800I-FP

Page 1: ...1 2 3 Total B1 B2 ACCESSORY OUTLET UNPROTECTED CURRENT VOLTAGE POWER WB 800I FP WB 800I FP WattBox Rack Mountable Faceplate Display 220 240V Quick Start Guide...

Page 2: ...tive earthing connection of the socket outlet is verified by a skilled person Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code a...

Page 3: ...ts that supply up to 1 5A each Two on the front and two on the back Three buttons for faceplate navigation and outlet control Accessory outlet on the front panel unprotected and non controllable Packa...

Page 4: ...5A maximum per port PDU Port Connections This faceplate is OvrC enabled To unlock the faceplate features in OvrC you must connect it to a compatible 800I series WattBox PDU on firmware version 2 3 0...

Page 5: ...he faceplate will remain on when resetting all outlets of the connected 800I series WattBox Once the faceplate and 800I series WattBox PDU are connected firmware updates are automatically pushed from...

Page 6: ...aw of all connected PDUs 6 Button 1 Sequences through PDUs 1 through 3 and Total left to right displaying the current for the specified PDU The aggregate of all PDUs displays when Total is selected Th...

Page 7: ...d PDU Note The LED flashes on the selected PDU for 5 minutes during this time the display windows show the voltage and current for the selected PDU After 5 minutes the faceplate returns to displaying...

Page 8: ...om the Faceplate Press and hold B1 and B2 at the same time for 3 seconds to reset all PDU outlets plugged into the faceplate The Current display shows a rotating 0 as the PDU outlets reset Note Outlet...

Page 9: ...Blue Slow Blink Enabled on all connected PDUs but incoming AC Voltage is not safe on at least one of the connected PDUs Off Safe Voltage is disabled on at least one of the connected PDUs Surge Protect...

Page 10: ...ks rack screws not included Cabinet Placement Remove the pre installed rack ears if desired and attach the supplied feet to the bottom of the WattBox faceplate for cabinet placement 1 2 3 Tot al B1 B2...

Page 11: ...R Y OU TL ET U NP RO TE CT ED CU RR EN T VO LT AG E PO W ER W B 80 0I FP 1 2 3 Total B1 B2 ACCESSORY OUTLET UNPROTECTED CURRENT VOLTAGE POWER WB 800I FP 1 2 3 Total B1 B2 ACCESSORY OUTLET UNPROTECTED...

Page 12: ...erved Snap One its respective logos are registered trademarks or trademarks of Snap One LLC formerly known as Wirepath Home Systems LLC in the United States and or other countries 4Store 4Sight Contro...

Reviews: