background image

 

WL350

 Manual 

                                                                   Page 56 – Revision 11‐21‐2018 

POWER TROUBLESHOOTING INDEX 

 

  

1.  Red Heater & Compressor Power Switch won't light and the Red LED on the Front 

won't light 
 

2.  Red Heater & Compressor Power Switch is lit but the red LED on the Front is not lit 
 
3.  Compressor Runs but does Not Chill 

 

4.  Compressor is Not Running  

 
 
1.

 

Red Heater and Compressor Power Switch won’t light and the Red LED on the 
Front won’t light 

 
 

Possible Reason 

Solution 

Circuit Breaker 

Check the Circuit Breaker 

Fuse is Blown 

Replace Fuse 

Defective / Loose Power Cord 

Check that Power Cord is properly plugged in.  If it is properly 
plugged in, use a different power cord to verify. 

Failed Socket ‐ Power Line 
Noise Filter, ElectroMagnetic 
Interference filter (EMI) 

Replace Socket ‐ Power Line Noise Filter, ElectroMagnetic 
Interference filter (EMI)

 

Defective Red Heater & 
Compressor Switch 

Replace Red Heater & Compressor Switch 

 
 
 
 
 
 
 
 
 