background image

 
 

 

 
 

 

 

 

   

Instruction manual

 

VWR

 

A-1000/A-1100/A-1200 

Sipper/Temperature Control System 

 

European Catalogue Number 
EU/UK/CH Plug:    634-1152 

 

A-1100 CONTROLLER, SIPPER FOR 

 

 

UV1600PC, UV-3100PC, V3000PC, UV6300PC 

 
EU/UK/CH Plug:    634-1153 

 

A-1000 CONTROLLER, SIPPER WITH   

 

 

CONSTANT-TEMPERATURE FOR 

 

 

UV1600PC, UV-3100PC, V3000PC, UV6300PC 

 
EU/UK/CH Plug:    634-1154 

 

A-1200 CONTROLLER,   

 

 

CONSTANT-TEMPERATURE FOR   

 

 

UV1600PC, UV-3100PC, V3000PC, UV6300PC 

 

 

 

 

 

Version: 

1.0.1 

Issued: 

16, June, 2020   

 

     

Summary of Contents for VWR A-1000

Page 1: ...4 1152 A 1100 CONTROLLER SIPPER FOR UV1600PC UV 3100PC V3000PC UV6300PC EU UK CH Plug 634 1153 A 1000 CONTROLLER SIPPER WITH CONSTANT TEMPERATURE FOR UV1600PC UV 3100PC V3000PC UV6300PC EU UK CH Plug 634 1154 A 1200 CONTROLLER CONSTANT TEMPERATURE FOR UV1600PC UV 3100PC V3000PC UV6300PC Version 1 0 1 Issued 16 June 2020 ...

Page 2: ...2 Legal Address of Manufacturer Europe VWR International bv Researchpark Haasrode 2020 Geldenaaksebaan 464 B 3001 Leuven 32 16 385011 www vwr com Made in China ...

Page 3: ...bols and conventions 11 Product Specifications 11 Getting Started 13 Using the instrument 14 Operation 16 Temperature Control 16 Sipper 17 System settings 19 Technical service 21 Warranty 21 Compliance with local laws and regulations 21 Equipment disposal 22 Local VWR offices in Europe and Asia Pacific 23 ...

Page 4: ...voltage area Danger Do not use the device if it is damaged especially if the main power cable way is in any damaged or defective Repairs may only be carried out by the service technicians from your authorized contractual partners The device must be connected to a power outlet that has a protective ground connection If the equipment is used in a manner not specified by the manufacturer the protecti...

Page 5: ...PC 10mm Single Cell Holder with Constant Temperature 1PC 10mm Flowing Quartz Cuvette 1PC Silicone Pipe with Limit Ring 1m Inner hole diameter φ2 Outer diameter φ4 1PC Silicone pipe 700mm Inner hole diameter φ2 Outer diameter φ4 1PC Constant Temperature Control Cable 1PC Power Cords EU UK CH Plug 1PC Instruction Manual 1PC ...

Page 6: ...with Limit Ring 1m Inner hole diameter φ2 Outer diameter φ4 1PC Silicone pipe 700mm Inner hole diameter φ2 Outer diameter φ4 1PC Power Cords EU UK CH Plug 1PC Instruction Manual 1PC Configuration list of A 1200 Description Quantity Constant Temperature Controller 1PC 10mm Single Cell Holder with Constant Temperature 1PC Constant Temperature Control Cable 1PC Power Cords EU UK CH Plug 1PC Instructi...

Page 7: ...d contractual partners Description The A 1000 series Constant Temperature Automatic Injection Controller is specially developed to meet the needs of some applications of our UV Vis spectrophotometer It is divided into 3 models according to different functions Model A 1000 Sipper with Temperature Control model A 1100 Sipper model A 1200 Temperature Control 1 2 4 5 7 8 9 6 3 10 11 ...

Page 8: ...ntrol Interface 11 Thermostatic Single Sample Holder Installation Placement Place the instrument on the stable table carefully Install thermostatic single sample holder Turn off the power of the instrument Remove the original sample holder and remove the original door insert As shown in the figure attach the thermostatic sample holder and tighten the two screws shown by the arrows ...

Page 9: ... constant temperature control cable The instrument is turned off As shown in the figure insert one end of the constant temperature control cable into the thermostat interface on the outside of the spectrophotometer door insert and the other end into the constant temperature control interface on the back of the controller 1 Constant Temperature Control Port 2 Constant Temperature Control Cable 3 Co...

Page 10: ...insert the injection end of the flow cuvette label 2 One end of the sample discharge pipe label 5 is connected to the sample end of the flow cuvette label 2 and the other end is passed through the sample hole of the cover plate 1 Injection Pipe 2 Flowing Cuvette 3 Sample Container 4 Waste Collection Container 5 Sample Discharge Pipe 1 5 2 3 4 ...

Page 11: ... voltage and warns the user to proceed with caution CAUTION This symbol indicates risks associated with hot surfaces Product Specifications Model A 1000 A 1100 A 1200 Function Sipper with Temperature Control Sipper Temperature Control Temperature Range 10 90 0 1 C interval adjustable 10 90 0 1 C interval adjustable Temperature Control Accuracy 0 1 0 1 Temperature Control appointment time 0 5 10h 0...

Page 12: ... stop 1 300s 1s interval adjustable or manual stop Sample Holder 10mm Single Cell Holder with Constant Temperature 10mm Single Cell Holder 10mm Single Cell Holder with Constant Temperature Display 4 3 Inch TFT Color Touch Screen Communication Interface Serial port RS232 1 USB B 1 Language 10 language switching English French German Spanish Portuguese Italian Russian Chinese Japanese Korean Power S...

Page 13: ...be activated by touch To make a selection use your finger or a capacitive stylus to press or slide the screen Press or slide the buttons terms and icons on the screen to make selections inputs and actions Note Do not press a screen with a sharp object such as a ballpoint pen tip Do not place any objects on top of the screen to avoid damaging or scratching the screen Touch screen operation Press Cl...

Page 14: ...and slide the icon to a position to change the setting value Using the instrument Main Interface The main interface is divided into two parts the left part is the temperature control area and the right part is the injection control area A 1000 1 2 3 4 5 6 5 6 ...

Page 15: ...nt temperature Set temperature Appointment time process Sipper control state Sipper speed Temperature control start Stop temperature control Recycle the sample in the flow cuvette after the end of the measurement Cleaning the flow cuvette 1 2 3 4 1 2 3 4 5 6 ...

Page 16: ...t temperature control Main interface Press the button Start on the left to pop up the temperature control parameter interface press the button to set the temperature control parameters according to the requirements Press the button OK the temperature control module start working Press the button Cancel to return to the main interface ...

Page 17: ...tment or set to no reservation Stop temperature control Main interface if temperature control is turned on press the button Stop on the left to end the temperature control Sipper Start sipper 1 Place the suction end of the silicone tube in the sample solution 2 Main interface press the button Injection on the right to pop up the injection control parameter interface press the button to set the inj...

Page 18: ...ameters according to the requirements Press the button OK to start recycling reach the set time or press the button Stop end Press the button Cancel to return to the main interface Time Time for single sample recycle range 1 300s interval 1s adjustment or set to continuous injection until manual stop Cleaning the flow cuvette 1 Place the suction end of the silicone tube in the cleaning solution 2 ...

Page 19: ...ange 1 300s interval 1s adjustment or set to continuous injection until manual stop Stop injection recycling cleaning Main interface if the injection recycling cleaning is in progress press the button Stop button on the right to end System settings The main interface press the icon to enter the system settings interface ...

Page 20: ...ife of the display Press the icon on the standby tab to turn it on off Turn beep on off when pressing the button on off Press the icon on the sound tab to turn the beep sound on off Language selection The instrument supports 10 language switching English French German Spanish Portuguese Italian Russian Chinese Japanese Korean press on the language parameter on the language label pop up the languag...

Page 21: ...maged by accident abuse misuse or misapplication or from ordinary wear and tear If the required maintenance and inspection services are not performed according to the manuals and any local regulations such warranty turns invalid except to the extent the defect of the product is not due to such non performance Items being returned must be insured by the customer against possible damage or loss This...

Page 22: ...It s also your responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycling of the equipment For more information about where you can drop off your waste of equipment please contact your local dealer from whom you originally purchased this equipment By doing so ...

Page 23: ...VWR International Northern Ireland Ltd Orion Business Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l Via San Giusto 85 20153 Milano MI Tel 39 02 3320311 02 487791 Email info it vwr com Korea VWR International 17 Daehak 4 ro Yeongtong gu Suwon si Gyeonggi do Tel 82 31 645 7256 saleskorea avantorsciences com Middle East ...

Reviews: