background image

OPTICAL CABLE CLOSURE 

Fiber Optic Splice Closure

 

(

VSOF-BS606G) User Manual

 

VISSEM VSOF--BS606G-Manual Rev.0        TEL: 031-288-3481      FAX: 031-283-7844 

All rights reserved by VISSEM Electronics Co. Ltd. 

       

       

 

 

1. Rotation Rocking-Lever 

 

Rotate the Locking-Lever through 90 degree. 

 

 

 

2. Closure Dismantle 

 

Open the Clip-Handle by using screwdriver or bare 
hand. 
After that dismantle the closure Body 

 

* When you open the Clip-Handle, it can be clacked 

 

 

3. Aerial Hanger Mounting to Closure 

 

Mount the aerial hanger to the joint part of lower 
main body with the using hexagonal headed bolt-
(M6*L25). 

 

 

 

4. Aerial Hanger Mounting to Messenger 
Wire 

 

Lower main body should be fixed on the messenger 
wire splicing point in the use of aerial hanger. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Removing Sheath of Optical Cable   

 

Remove 1.2m of the cable sheath from Cable end. 
Remove the aramid and fiber yams. 

 

 

9. Opening the Tray-Supporter 

 

Push the hook of Tray-Supporter and open the 
Tray-Supporter. 

 

 

6. Cutting Tension Member 

 

Cut Tension member 10cm from the Cutting Plane. 

 

* Be careful not to cut loose tube. 

 

 

10. Cutting Sheath Gasket 

 

Cut the A line of Sheath Gasket 
by using cutting tool such as 
scissors. 

 

* make a cutting surface clearly 
when you cutting 

 

 

7. Removing Loose Tube 

 

Remove all but 8cm of each loose tube. 
Clean the remaining loose tube, exposed fiber and 
strength member with a cloth and jelly cleaner. 

 

 

11. Removing Sheath Holder (Top) 

 

With the aid of a screwdriver, loosen the two bolt of 
Sheath Holder at each end. 
Afterward remove the sheath holder (top). 

 

* Keep the sheath holder (top) carefully not to drop. 

 

 

8. Inserting Unit Protection Tube 

 

Insert one Unit Protection Tube on loose tube and 
slide it down to the sheath Cutting Plane. 
Wrap cable with tape to hold Unit Protection Tube. 

 

* Length of Protection Tube provided : 55cm 

 

 

12. Applying High Vacuum Grease 

 

Apply the high vacuum grease on the cable for 

excellent water-proof. 

Clip-Handle 

Cover 

Body 

Tray Ass`y 

Tray-Supporter 

Protection Tube Guide 

T/M   

Steel band bracket 

Sheath Holder 

Sheath Gasket 

Sheath Holder 

(Top) (Φ12 ~ Φ20) 

Sheath Holder 

(Bottom) 

Blot 

(M5*L40) 

High Vacuum 

Grease 

Grease Brush

 

Cable Tie 

Splice Protection 

Sleeve 

Insulation 

tape 

Aerial Hanger 

Bolt 

(M6*L25) 

Silica Gel 

Unit Protection Tube 

10cm 

8cm 

Reviews: