User manual

 

 

Spirit G XL 

1-3 KVA 

– PF0.9 

 

U

ninterruptible 

P

ower 

S

upply

 

 
 
 

 

 
 
 

Содержание Spirit G XL 1.5KVAH

Страница 1: ...User manual Spirit G XL 1 3 KVA PF0 9 Uninterruptible Power Supply...

Страница 2: ...lp you to reach maximum life time of your UPS This manual explains the inner working principle and the corresponding protective functions Furthermore it contains information regarding the use of the e...

Страница 3: ...3 Connectivity Cards 26 5 4 Emergency Power Off EPO 27 5 5 Load Segments 28 5 6 UPSilon2000 Power Management Software 28 6 Maintenance 29 6 1 Maintenance of UPS and Batteries 29 6 2 Storing the UPS an...

Страница 4: ...uarantee that interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the...

Страница 5: ...tion Cold start function to start up the UPS without utility Standard communication options one RS232 communication port one USB communication port and relay output contacts or SNMP card Power sheddin...

Страница 6: ...f 20 C to 25 C Do not place any liquids on the UPS cabinet in order to not trigger electrical discharges nor other dangers To reduce the risk of fire connect only to a circuit provided with branch cir...

Страница 7: ...on Avoid places with vibrations dust high humidity flammable gas liquids and corrosion 3 1 5 The ambient temperature must not exceed 40 C maximum To preserve batteries lifetime we advise an operating...

Страница 8: ...l wiring between inverter and external batteries is installed behind the front cover and thus inaccessible to users NOTE mounting rails are required for each individual cabinet 3 3 3 Installation of t...

Страница 9: ...front of the UPS to the rack by using one M5x12 pan head screws and one M5 cage nuts on each side see fig 6 Install the bottom screw on each side through the bottom hole of mounting bracket and the b...

Страница 10: ...al batteries then the plug is already connected CAUTION A small electric arc may occur when connecting the internal batteries This is normal and will not harm personnel Connect the cables quickly and...

Страница 11: ...Ps Follow these steps to install the battery packs EBPs for a UPS Remove the front cover of each EBP and of the UPS see fig 11 as explained in section Installation of the UPS Remove the small cable kn...

Страница 12: ...EBP connections are tight and the adequate bend radius and strain relief exist for each cable Replace the EBP front cover after verifying that the EBP cables are correctly routed through the EBP cover...

Страница 13: ...nstallation The fig 16 A shows one UPS in tower installation and fig 16 B shows the tower installation of UPS and battery packs EBPs Install the base and then place the RT UPS one after another on the...

Страница 14: ...hat on table 23 Troubleshooting on page 36 If the indicator is on do not proceed until you have removed all alarms Check the UPS status on front cover to view the active alarms Correct the alarms and...

Страница 15: ...ption Start up combination RT Press and hold these keys longer than second to turn on the UPS or to turn it off Rotating combination RT Press and hold these keys longer than 2 seconds to circumrotate...

Страница 16: ...nection or start 6 times Ensure that the battery is connected properly 5 Output overload protection Overload warning in LINE mode 2x per second Remove less important loads Overload in LINE mode protec...

Страница 17: ...phical section Graphical display of the capacity of battery and load Each square represents 20 of capacity As the adjacent graphic shows the load reaches 80 100 5 squares and the capacity of battery i...

Страница 18: ...ent graphical example shows the charge is 100 WATT and 100 VA at disconnected load it is normal that the indicated numerical value of WATT and VA is small Temperature Display of the inverter temperatu...

Страница 19: ...hold the function setting key longer than 2 seconds to reach the setting interface Press and hold the scroll key longer than second shorter than 2 seconds to select bPS setting The letters bPS will f...

Страница 20: ...face Press and hold the function setting key longer than 2 seconds to reach the setting interface Press and hold the scroll key longer than second shorter than 2 seconds select function setting choose...

Страница 21: ...formation please refer to table 24 EPO input polarity setting Enter the setting interface Press and hold the function setting key longer than 2 seconds to reach the setting interface Press and hold th...

Страница 22: ...the UPS is operating in LINE mode charging the battery and protecting the load Battery mode The green inverter LED and the yellow battery LED are lighting the buzzer beeps once every 4 seconds The red...

Страница 23: ...ss and hold the ON key longer than second to start the UPS The operation of the UPS in start process is almost the same as when there would be mains current After finishing the self test the correspon...

Страница 24: ...ns two battery strings WARNINGS The following process must be performed if the UPS is connected with a generator First turn on the generator As soon as its runs stable connect the output power of the...

Страница 25: ...priate connectivity interface card and or the necessary cables Connect the cables to the appropriate location Route and tie the cable s out of way Continue as described under point 4 5 Start up and Tu...

Страница 26: ...ay interface card has isolated dry contact relay outputs for UPS status utility failure low battery UPS alarm or OK or Bypass ON See figures 19 and 20 on page 25 for the location of the communication...

Страница 27: ...s are detailed in Harmonized document HD 384 48 S1 Electrical Installation of the Buildings Part 4 Protection for Safety Chapter 46 Isolation and Switching b NOTE Leave the EPO connector installed ont...

Страница 28: ...UPSilon2000 Power Management Software Each UPS is delivered with the UPSilon2000 Power Management Software For installation of this software refer to the instructions accompanying the software CD NOT...

Страница 29: ...stalled refer to table 21 Battery runtimes at 100 load at page 34 for recharge times Check the date of battery recharge on the shipping carton label If the date is expired and the batteries were never...

Страница 30: ...ling a new battery pack ensure that it is completely inserted into the chassis support see figure 27 6 5 Testing New Batteries To test new batteries execute the following steps Connect the UPS to the...

Страница 31: ...ICATIONS 7 1 Model Specifications This chapter provides information about following specifications communication options model list weights and dimensions electrical input and output environment and s...

Страница 32: ...current Selectable input voltage Voltage range at 100 load 1KVAS 1KVAH 230V 4 4A 200 208 220 230 240 160 290Vac 1 5KVAS 1 5KVAH 230V 6 5A 200 208 220 230 240 160 290Vac 2KVAS 2KVAH 230V 8 7A 200 208 2...

Страница 33: ...20 C14 10A 2KVA RT IEC C13 10A 6 IEC 320 C14 10A 3KVA RT IEC C13 10A 6 IEC C19 16A 1 IEC 320 C14 10A IEC 320 C20 10A TABLE 19 Environment and safety all models 208 230 240Vac models Surge suppression...

Страница 34: ...EBPs 4 EBPs 1KVAS 24Vdc 3 15 25 40 53 1KVAS 36Vdc 5 25 45 65 85 1 5KVAS 36Vdc 3 15 25 40 53 2KVAS 48Vdc 3 15 25 40 53 2KVAS 72vdc 5 25 45 65 85 3KVAS 72Vdc 3 17 31 52 69 NOTE The battery runtimes are...

Страница 35: ...SPIRIT G XL 1 3 KVA PF0 9 UPS www visionups com 35 7 2 Rear covers Fig 28 Fig 29...

Страница 36: ...input power cable and make a correct connection Battery capacity indicator flashes Low battery voltage OR battery disconnected Check UPS battery connect the battery correctly If the battery is damaged...

Страница 37: ...4 52 96 Soft fail 63 Bus discharge fail 61 Overheat 33 06 08 43 53 INV short 16 02 44 73 Overload 03 09 45 65 Fan fault 36 28 38 46 66 Charger fault 07 17 27 Bat over 11 12 13 InvRelaySht 76 LineNTCBr...