Страница 1: ...fessional Freestanding Ranges Installation Guide Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit vikingrange com F21234B EN 041014 ...

Страница 2: ...hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Warnings Important Safety Instructions _______________________________________________3 Dimensions _________________________________________________________________________6 Specifications _______________________________________________________________________8 Clearance Dimensions ...

Страница 3: ...ath and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed operated and maintained in accordance to the instructions in this document TIPPING HAZARD To reduce the risk of property damage or personal injury install anti tipping device provided...

Страница 4: ...island trim Note All ranges installed with a backguard against a combustible wall require a standoff with the backguard which will add 3 4 1 9 cm to the overall range depth 36 and 48 W Ranges Note Unit shown with standard island trim Dimensions Dimensions ...

Страница 5: ...uction Below cooking surface 36 91 4 cm and below Sides 0 Top grate support 36 91 4 cm Above cooking surface above 36 91 4 cm Sides 12 30 5 cm Within 12 30 5 cm side clearance wall cabinets no deeper than 13 33 0 cm must be minimum 18 45 7 cm above cooking surface Wall cabinets directly above product must be a minimum of 58 147 3 cm above cooking surface unless a range hood is installed above the ...

Страница 6: ...here must be a minimum of 12 30 5 cm side clearance from the range to such combustible surfaces above the 36 91 4 cm counter height Within the 12 30 5 cm side clearance to combustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 12 30 5 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wall cabinets above...

Страница 7: ...se a 4 wire agency approved power supply kit with closed loop terminals rated per the National Electrical Code ANSI NFPA 70 latest edition See Rating chart below RATING Specified Rating of Power Supply Cord Kit and Circuit Protection 120 240 Volts 120 208 Volts Amps 12 5 16 5 KW 9 2 12 5 KW 40 or 50 16 5 17 5 KW 12 5 13 5 KW 50 The National Electric Code calculation for Electrical Load is less tha...

Страница 8: ...rates burner heads and bases from the cardboard top packaging DO NOT discard the metal brackets supplied with the range These are the anti tip devices and must be installed with the unit Refer to Anti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film res...

Страница 9: ...ord mounting screws on terminal block Electrical shock hazard To avoid risk or electrical shock personal injury or death grounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used Electrical shock hazard To avoid risk of electrical shock personal injury or death verify your appli...

Страница 10: ...ttach access door Remove access door Remove supply cord strain relief bracket and three supply cord mounting screws on the terminal block Electrical Connection 4 wire Dual Fuel Ranges Remove grounding screw Cut off and discard ground strap Installation Installation Feed supply cord up through hole in bottom of range back Attach ground lead green with ground screw that was removed Attach line 1 red...

Страница 11: ...orner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening Lift unit and prop on wood blocks 20 Push supply cord toward terminal block to relieve strain reattach supply cord strain relief bracket over supply cord Reattach access door Leveling Adjustments Alignment Leveling Adjustments Alignment con t Electrical Connection 4 wire cont Installation Installation Set t...

Страница 12: ...ed Installation Installation Anti tip Device Installation Floor Mount Locate anti tip bracket hook on the floor 8 1 2 21 6 cm from side cabinet and 1 1 2 3 8 cm from rear wall Mark and drill 1 8 32 cm holes where bracket will be located Mount anti tip bracket hook to floor using screws provided Remove two screws from back of range Attach bracket to back of range using two screws Connect gas and el...

Страница 13: ...e 3 8 0 95 cm above countertop If unit is not level repeat Steps 5 7 of Leveling Adjustments Alignment section Slide range into place Be sure wall anit tip bracket slides into the anit tip opening and floor anti tip hook and bracket are engaged Final Installation FIRE HAZARD Backguards come standard with standoff spacers which provide a barrier between back of range and rear wall These must be in ...

Страница 14: ...____________________________________ Address ___________________________________________________________________________________________ These installation instructions should remain with the unit for future reference 26 Performance Checklist A qualified installer should carry out the following checks Check top burner ignition See drawing for proper flame height on HI The low flame should light at...