background image

 

 

USER MANUAL 

 

Box 79 Industrivägen 3 

 

Tel. +46 (0)176-208920

 

Web     

www.vetek.com

  

76040 Väddö, Sverige  

 

Fax +46 (0)176-208929

  

Email   

[email protected]

  

 

 
 

Personal scale WBA-300 with  

PROFESSIONAL ELECTRONIC COMPOSITION  

 

USER MANUAL 

                                            

  

   

 

    

Read this manual carefully before using the instrument

 

 

INDEX 

2. 

GENERAL RULES………..…………………………………………………………………………………………………………………………………….. 

PAG. 2 

3. 

SAFETY………………………………………………………………………………………………………………………………………………………….. 

PAG. 3 

4. 

THECHNICAL SPECIFICATION………….…………………………………………………………………………………………………………………... 

PAG. 4 

5. 

INDICATOR…………………..………………………………………………………………………………………………………………………………….. 

PAG. 5 

6. 

INSTALLATION………………………………………………………………………………………………………………………………………………….. 

PAG. 7 

GENERAL CONDITIONS FOR CORRECT MEASUREMENTE………………………………………………………………………….……………….. 

PAG. 8 

8. 

INSTRUCTION FOR USE……………………………………………………………………………………………………………………………………… 

PAG. 8 

9. 

PRINT FUNCTION……...………………………………………………………………………………………………………………………………………. 

PAG. 12 

10. 

MAINTENANCE AND ASSISTANCE………..………………………………………………………………………………..………………………………. 

PAG. 13 

11. 

COMFORMITY…………………………………………………………………………………………………………………………………………………... 

PAG. 13 

12. 

SCRAPPING AND WASTE DISPOSAL...…………………………………………………………………………………………………………………….. 

PAG. 13 

13.           WARRANTY………………………….…….……………………………………………………………………………………………………………………. 

PAG. 14 

14 

THERMAL PRINTER..…………………………………………………………………………………………………………………………………………. 

PAG. 15 

15. 

ASSEMBLY-USE MECHANICAL TELESCOPIC HEIGHT METER (OPTIONAL)………………………………………....…………………………….. 

PAG. 18 

 

 

 

By choosing the 

WUNDER

 mod. 

WBA

 professional electronic scale, you have purchased a high precision instrument. 

Since over 40 years 

WUNDER

 has placed its experience at the service of health.  This instrument is calibrated in conformity with accuracy class 

III

.  

The instrument is characterized by the possibility of fixing the electronic terminal to the weighing platform by means of a column or else installing the terminal autonomously. 

The instrument is equipped with a dual LCD electronic terminal with triple reading to simultaneously view Weight, Height. and BMI 

Summary of Contents for WBA-300

Page 1: ... COMFORMITY PAG 13 12 SCRAPPING AND WASTE DISPOSAL PAG 13 13 WARRANTY PAG 14 14 THERMAL PRINTER PAG 15 15 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL PAG 18 By choosing the WUNDER mod WBA professional electronic scale you have purchased a high precision instrument Since over 40 years WUNDER has placed its experience at the service of health This instrument is calibrated in conformity ...

Page 2: ...e them without being committed to update this publication Conventions The following symbols have been used in this manual 0470 MEDICAL CERTIFICATION METROLOGICAL CERTIFICATION AND APPROVAL FOR MEDICAL USE ACCURACY CLASS ASSISTANCE WARRANTY CERTIFICATE ATTENTION PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN DAMAGE THE PRODUCT WARNING PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAI...

Page 3: ...pliances Make sure that the power cord does not create obstruction hazards Unplug the instrument before cleaning it Do not place the instrument in water or other liquids Perform maintenance and subsequent metric verifications regularly WARNING People with pacemakers and other medical devices internal Note that people with an electronic medical implant such as a pacemaker should not use WBA as it p...

Page 4: ...Ω 0 1Ω Age Range 10 80 years increase of 1 year Height Range 60 210cm 3ft 7ft 11 0in Power Rechargeable Batteries 7 2V 2000mA o batteries AA 1 5X6 9V Medical Adapter AC 12V 2A Platform dimension 340 L x 450 P x 80 H mm Temperature Use 5 C 35 C 30 80 UR Storage temperature 20 C 60 C 0 90 UR Output RS232 9 pin female Optional not included External thermal printer Telescopic height meter Printer Data...

Page 5: ...le Sex Male ATHETIC MODE means a person subject to intense physical activity for at least 12 hours a week and with a resting heart rate of 60 beats per minute or less They are also considered athletic people if for some years they have practiced sport and they currently exercise less than 12 hours per week Are not considered in this mode beginners while exercising for at least 12 hours a week have...

Page 6: ...e Fax 46 0 176 208929 Email info vetek com 6 6 INSTALLATION ATTENTION AFTER HAVING VERIFIED THE INTEGRITY OF THE EQUIPMENT AND OF ALL ITS COMPONENTS CONNECT THE INSTRUMENT WITH THE SUPPLIED POWER SUPPLY TO CORRECTLY RECHARGE THE BATTERIES Position the instrument on a level and stable surface ...

Page 7: ...Assembly for column version only Figure A Assembly is easy fix scale s column to the weighing platform See Figure A ATTENTION FOLLOW THE INDICATIONS BELOW BEFORE INSERTING THE COLUMN Figure B Figure C Overturn the weighing platform resting it onto a level surface Remove the display connector from inside the column and connect it to the weighing platform connector making it pass through the hole in...

Page 8: ...ver possible avoid performing the test after taking a shower or a sauna The exudation causes temporary changes in body composition 6 Did not take the test during the menstrual cycle Women experience an increase in water in the body during the menstrual cycle 7 Perform the test at normal temperatures 20 C 25 C While the human body is stable at normal temperatures body composition is susceptible to ...

Page 9: ... set Time programming Use the number keys to enter the correct value press HOLD to confirm the entered date and time once correctly set Display format YYYY MM DD HH MM 8 3 ONLY WEIGHT Questo strumento può essere utilizzato anche come normale bilancia 1 Press the power button 2 Place the patient and the first display will show the weight 8 4 WEIGHT BODY COMPOSITION WARNING THE INFORMATION PROVIDED ...

Page 10: ...eb www vetek com 76040 Väddö Sverige Fax 46 0 176 208929 Email info vetek com 10 1 Pess the key the top display shows 0 0kg 2 Select the body conformation with the key or or and press the key to confirim 3 Insert height and press 4 Insert age eight and press ...

Page 11: ...isplay shows oooo and begins the analysis of the body When the symbols oooo is moving indicate the measurement body of the analysis and 6 the lower display shows BMI and 7 Press to displays the age and height To print the results control that the printer is on Press the key of the printer to print the results The measured data can be printed using thermal printer date and time Data included body t...

Page 12: ...cting the numeric keypad and pressing 0000 then press confirm 9 PRINT FUNCTION The format presented below is the standard format of results print out and cannot be changed More information info wunder it or service wunder it Start Menu Programs Accessories Communication Hyper Terminal Standard EIA RS 232 Compatible Method of communication Transmission asynchrony Speed 9600 bps Data length 8 bits P...

Page 13: ... or neutral detergent without using solvents or abrasive substances If the instrument remains idle for a long period remove the batteries from the terminal During shipping make sure not to subject the instrument to blows or excessive mechanical stress In case of repairs or assistance contact your dealer or an authorized service centre contacting service2 wunder it or sales wunder it 11 CONFORMITY ...

Page 14: ...NTION Do not throw electric parts and used batteries away with household waste Dispose of the batteries by means of your closest collection centres 13 WARRANTY This certificate must be kept until the warranty has expired It must be presented together with the invoice tax receipt or delivery note providing the name of the dealer and date of purchase whenever a technical intervention is required Oth...

Page 15: ...indirectly to persons animals or objects resulting from failure to comply with all the instructions indicated in this manual or anyway resulting from improper use The Court of Bergamo has jurisdiction in case of any dispute 14 THERMAL PRINTER OPTIONAL Read this manual carefully before using the instrument Platen Rollen Tear Bar Printer Button Status Indicator Roll Holder RS 232 connect Power Adatt...

Page 16: ...power on the printer The PRINTER XL printer can be connected via the RS232 port and cable with the RA200 XL Press the PRINT key Print double language CHANGING THE PAPER ROLL The paper print roll on a PRINTER XL printer is changed as follows 1 Open the upper cover and position the paper roll so that it feeds in the right direction 2 Feed the end of the paper roll through the printer cover and close...

Page 17: ...hod Thermal dot line printing Number of dots 384 dot line Resolution dots mm 8 dot mm Printing width mm 48 mm Max paper thickness μm 80μm Paper 57 5 0 5 mm W x ψ30mm max Paper loading Easy loading Printing speed mm s 75 mm s Dimensions L x W x H 120 x 80 x 50mm Operating temperature 0 to 50 Operating humidity 20 to 85 no condensation Interface Conform to RS232 Voltage range adaptor only 12V 2A ...

Page 18: ...n Status Indicator does not light when power switch is turned to ON I position Check the power connections from AC outlet to the printer power supply Status indicator illuminated green light but the printer will not print Check interface cable connections from the scale to printer Make sure the top cover is closed and locked Printer paper jammed Reset the paper roll Please refer to CHANGING THE PA...

Page 19: ...1 cm MEASURING UNDER 130 cm 1 Pull up the height meter rod 1 Press the black button and measuring height and push down Picture 1 Assemble white metal support with abs black part white the screws B E Lock all with the screws D 1 1a Picture 2 2a behind the pole column assemble the white metal support with screws B Picture 2b the position is on the right 2 2a 2b Picture 3 3a assemble the height rod o...

Page 20: ...info vetek com 20 2 Position it horizontally 2 3 Lower the rod up to the point where the lever rests head touches the patient s head The height can be read at the point A 3 Position it horizontally 4 Lower the rod up to the point in which the blade rests head touches the patient s head The height can be read at point B ...