background image

VTi

®

 CELTIC 

DRAPERY MOTOR

MOTOR VTi

®

 CELTIC PARA

CORTINAS TRADICIONALES

vertilux.com

PROGRAMMING INSTRUCTIONS

MANUAL DE PROGRAMACIÓN

Summary of Contents for 1-700-DM-00064

Page 1: ...VTi CELTIC DRAPERY MOTOR MOTOR VTi CELTIC PARA CORTINAS TRADICIONALES vertilux com PROGRAMMING INSTRUCTIONS MANUAL DE PROGRAMACI N...

Page 2: ...ing on the fabric to initiate movement Stop on contact the motor stops when it finds an obstacle that offers resistance to its movement Manual operation option when there is a power outage Maximum wei...

Page 3: ...leting a single motor or channel Deleting the motor from all channels Resetting the motor to factory default 1 Pair the motor with the remote control 2 Operate the motor in both directions until the m...

Page 4: ...er carrier Center Open Max weight 1 Nm Motor 40 kg I 88 lb 2 Nm Motor 60 kg I 132 lb Track size 12 m I 39 ft Max weight 1 Nm Motor 50 kg I 110 lb 2 Nm Motor 75 kg I 165 lb Track size 12 m I 39 ft Max...

Page 5: ...a PC or with a home automation system This option allows to operate multiple motors at the same time with a RS485 dry contacts or a PC Wiring Group control Antenna Port 1 Port 2 Programming button Mo...

Page 6: ...ondary control Included with the motor 1 The motor includes a main and secondary control Both pieces are equal and can be placed on either track end Aluminum track 6 700 DM 00009 2 Drive belt 6 700 DM...

Page 7: ...00008 Only for one way installations 2 Carriers 6 700 DM 00006 Use the following components for a Ripple Fold system Use the following components for a Pinch Pleat system 1 Master Carrier 6 700 DM 000...

Page 8: ...le when pressing the up button on the remote control the drapery closes or when pressing the down button the drapery opens Checking the traversing direction 1 Press and hold the programming button on...

Page 9: ...TOP BUTTON PREVIOUSLY PROGRAMMED REMOTE CONTROL NEW REMOTE CONTROL OR CHANNEL UP BUTTON This is convenient when there has been a programming mistake and it is required to delete the programming from a...

Page 10: ...ttings It is not necessary to turn off all motors previously programmed in the remote control Resetting the motor to factory default 1 Press and hold the programming button located on the head of the...

Page 11: ...tural aproximadamente 15 cm Parada por obstrucci n el motor se detiene autom ticamente cuando encuentra un obst culo que causa resistencia a su movimiento Opci n de operaci n manual en la ausencia de...

Page 12: ...ecciones hasta los extremos del riel permitiendo que el motor autoajuste sus l mites electr nicos Funciones opcionales Cambiar la direcci n de desplazamiento de la cortina Adicionar un nuevo control r...

Page 13: ...t Carga m xima Motor 1 Nm 50 kg I 110 lb Motor 2 Nm 75 kg I 165 lb Tama o del riel 12 m I 39 ft Carga m xima Motor 1 Nm 70 kg I 154 lb Motor 2 Nm 105 kg I 231 lb Tama o del riel 12 m I 39 ft Carga m x...

Page 14: ...e motores al mismo tiempo a trav s de una PC contactos secos o se ales seriales RS485 Cableado Control en grupo Antena Puerto 1 Puerto 2 Bot n de programaci n Motor A Motor B Control v a RS485 contact...

Page 15: ...eat Soporte L 0 030 CA 06600 5 Clip instalaci n a techo 6 700 DM 00010 6 Clip de pl stico 6 700 DM 00011 Incluido con el motor 7 Conector de riel 6 700 DM 00012 Opcional No aparece en el diagrama 8 1...

Page 16: ...Solo para instalaciones de apertura lateral 2 Carritos 6 700 DM 00006 Utilice los siguientes componentes si desea fabricar una cortina Ripple Fold Utilice los siguientes componentes si desea fabricar...

Page 17: ...presionar el bot n de bajada la cortina se abre Cambiar la direcci n de desplazamiento de la cortina 1 Mantenga presionado el bot n de programaci n en el cabezal del motor por aproximadamente 1 s hast...

Page 18: ...ambi n se aplica si se desea borrar un motor de un canal espec fico Desconecte de la corriente todos los motores excepto el que desea borrar y siga el procedimiento Borrar el motor de un canal o borra...

Page 19: ...brica No es necesario desconectar todos los motores programados previamente en el control remoto Configurar el motor a sus valores de f brica 1 Mantenga presionado el bot n de programaci n ubicado en...

Page 20: ......

Reviews: