L101 0810A

Page 1

24”

10”

20”

28”

24 ¾”

RM1000

UL

C

US

R

24”

12 ¼”

20”

28”

24 ¾”

RM1500

CFM Ratings and Electrical Specifications

Model

CFM At Static Pressure Ps = Inches of Water

Volts

Amps

Hz

Duct

Size

0.0" Ps

0.1" Ps

0.2" Ps

0.3" Ps

0.5" Ps

RM1000

945

922

884

852

770

120

3.2

60

10"

RM1500

1500

1455

1410

1375

1295

120

5.0

60

10"

INSTALLATION INSTRUCTIONS

FOR REMOTE BLOWER MODEL RM1000 & RM1500

READ AND SAVE THESE INSTRUCTIONS

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING:

A.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the 

address or telephone number listed on the back cover of 

the Homeowner’s Manual.

B.  Before servicing or cleaning unit, switch power off at the 

service panel and lock the service disconnecting means to 

prevent power from being switched on accidentally. Then 

the service disconnecting means cannot be locked, securely 

fasten a prominent warning device, such as a tag, to the 

service panel.

C.  Installation work and electrical wiring must be done by 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and 

standards.

D.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent back drafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as 

those published by the National Fire Protection Association 

(NFPA), and the American Society for Heating, Refrigeration, 

and Air  Conditioning  Engineers  (ASHRAE),  and  the  local 

code authorities.

E.  When Cutting or drilling into wall or ceiling, do not damage 

electrical wiring or other hidden utilities.

F.  Ducted fans must always be vented to the outdoors.

WARNING

1.  TO REDUCE THE RISK OF FIRE, USE ONLY METAL 

DUCTWORK.

2.  THIS FAN IS UL LISTED FOR USE WITH VENT-A-HOOD 

MODEL B210R.

CAUTION

1.  FOR GENERAL VENTILATION USE ONLY. DO NOT USE 

TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS 

AND VAPORS.

INSTALLATION TIPS

1.  For best performance, keep duct length and number of 

elbows to a minimum. 10” round ducting or equivalent is 

recommended.

2.  Select a location that is free of obstacles such as heating and 

air conditioning ducts, water pipes, electrical wiring, etc.

3.  Position discharge of the blower down towards ground level 

and away from prevailing winds to minimize back drafts.

4.  For best appearance, locate the fan on the rear of the house, 

below the top of the roof line.

PRODUCT SPECIFICATIONS