Copyright © 2009 Vent-Axia Limited. All rights reserved.

 

 

 

 HR500IP 

 

Passive Semi-Remote  
Wall Mounted Heat Recovery Unit 
with Spigot Connections. 

  Installation Instructions    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                 

 

Stock Ref. N° 

370447    -    HR500IP 
 
 

 

 

 

 

PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. 

Summary of Contents for HR500IP

Page 1: ... Axia Limited All rights reserved HR500IP Passive Semi Remote Wall Mounted Heat Recovery Unit with Spigot Connections Installation Instructions Stock Ref N 370447 HR500IP PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT ...

Page 2: ...building from the open flue of gas or other fuel burning appliances 5 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 6 Young children should be supervised to ens...

Page 3: ...hieved by using in line duct fans or wall mounted units to suit the length and configuration of ducting systems The unit is compatible with Ø300mm flexible duct and is ideally suited for use with in line fans and external wall louvres Concentric reducers are available to convert inlet and exhaust spigots to 250mm or 200mm diameter for use with alternative sized fans and ducting if required Typical...

Page 4: ...port of the building fabric if required If used this will automatically produce a 3 slope of the unit away from the inner grille for drainage of any condensate which may form during operation A 22mm drain is situated between inlet and exhaust spigots and should be connected to a suitable drain soakaway Fixing hole opening Supply Extract 370mm 600mm FRONT Ø290 PLAN ...

Page 5: ...vated will turn red over 6 months It should be used to keep track of when the filter and cell need cleaning replacement Using the self adhesive backing the strip can stuck near the units controls or in a easily visible place A normal cleaning schedule for a unit would be as follows Note The above is the minimum requirement more frequent cleaning intervals may be needed depending on the environment...

Page 6: ...ff the backing liner and stick the Timestrip to the Unit or near the controls of the unit The location should make it obvious to the person responsible for maintenance that the unit needs attention 3 Once activated the red dye will indicate elapsed time by moving through the white window and past each time marker The progress of the red dye is irreversible and each Timestrip can only be used once ...

Page 7: ...pology Manual Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either supply or extract air side N A Position and description of visual filter warning for RVUs intended for use with filters in...

Page 8: ...eing found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit Has not been subjected to ...