background image

      Venstar Inc. 05/08

Use  with  most  Air  Conditioning  &  Heating  Systems  including:  1  Stage 
Electric Cooling & 1 Stage Gas Heating, Heat Pump, Electric or Hydronic Heat. 

Digital 

Thermostat

Digital 

Thermostat

residential

T0130

THERMOSTAT

OWNER’S 

MANUAL

OWNER’S 

MANUAL

Stages: 1-Heat, 1-Cool
Heat Pump Compatible
Battery or System Powered
Fahrenheit or Celsius
Fully Electronic

HEAT

COOL

HEAT

PUMP

PROGRAMMABLE

NON-

PROGRAMMABLE

NON-

up to 

& 1-cool

up to 

& 1-cool

1-heat

1-heat

Bi-Color LED 

(when system powered)

 

Summary of Contents for T0130

Page 1: ...Hydronic Heat Digital Thermostat Digital Thermostat residential T0130 THERMOSTAT OWNER S MANUAL OWNER S MANUAL Stages 1 Heat 1 Cool Heat Pump Compatible Battery or System Powered Fahrenheit or Celsius Fully Electronic HEAT COOL HEAT PUMP PROGRAMMABLE NON PROGRAMMABLE NON up to 1 cool up to 1 cool 1 heat 1 heat Bi Color LED when system powered ...

Page 2: ...move Old Thermostat Safety Warnings Front Panel Display Normal Operation Preparation Battery Replacement Warranty Test Operation Troubleshooting Wire Connections Jumper Configuration Fahrenheit or Celsius OWNER S MANUAL T0130 ...

Page 3: ...isplay when it is time to replace the batteries If the thermostat is connected to 24v power the batteries should still be installed but are not required When Low Battery is displayed the batteries must be replaced immediately The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced Annual battery replacement is especially critical in ...

Page 4: ...f Controls Page 4 OWNER S MANUAL T0130 BATTERY DOOR On or Auto FAN SWITCH COOLER WARMER BUTTONS DISPLAY MODE SWITCH Cool Off or Heat BI COLOR LED Heat or Cool demand indicator when system powered Red Heat Green Cool ...

Page 5: ...urrent room temperature to the desired set temperature Current room or set temperature Indicates battery life is low it is recommended to replace the batteries at this time OWNER S MANUAL T0130 Heat and Cool indicators In normal operation Heat or Cool appears depending on the Mode Switch position When heat or cool is energized the Heat or Cool indicator will flash If the thermostat is system power...

Page 6: ...LER WARMER BUTTONS Operation Select Cool or Heat with the Mode Switch Normally leave the fan switched to Auto In Fan Auto the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously Adjust the desired set temperature with the COOLER or WARMER buttons T0130 ...

Page 7: ...Mode Switch Press and hold the COOLER and WARMER buttons at the same time until the temperature is displayed in degrees Celsius Repeat this process to display the temperature in degrees Fahrenheit OWNER S MANUAL MODE SWITCH Cool Off or Heat T0130 COOLER WARMER BUTTONS ...

Page 8: ...structions Turn off the power to the Heating Air Conditioning system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Proper installation of the thermostat will be accomplished by following these step by step instructions If you are unsure about any of these steps call a qualified technician for assistance Preparation OWNER S MANUAL T01...

Page 9: ...Disconnect the wires from the old thermostat Tape the ends of the wires as you disconnect them and mark them with the letter of the terminal for easy reconnection to the new thermostat Keep the old thermostat for reference purposes until your new thermostat is functioning properly Remove Replace Old Thermostat Page 9 OWNER S MANUAL T0130 70 HEAT 70 HEAT 70 HEAT 70 HEAT ...

Page 10: ...thermostat fig 1 To open the battery slot press down on the battery cover fig 1 and pull out fig 2 Place the bottom hook of the battery cover into the slot and snap closed fig 4 Page 10 OWNER S MANUAL Remove the old batteries and replace with the new AA alkaline batteries fig 3 T0130 FIG 1 FIG 2 Press down Pull out Battery slot FIG 3 batteries New batteries in FIG 4 Snap closed Bottom Hook Bottom ...

Page 11: ...ermostat terminal marked Function Install on the new thermostat connector marked C Common Y1 or Y Cooling Y W1 W or H Heating W G or F Fan G O B Rev Valve O B C optional RC R M Vr A Power RC Cooling Transformer RH R M Vr A Power RH Heating Transformer The RC and RH terminals have a factory installed jumper to control single transformer systems Remove this jumper to control dual transformer systems...

Page 12: ... not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 4 Wire 1 Stage Cooling 1 Stage Heating Residential Gas or Electric Heat Electric Cool split systems package units For jumper configuration see pages 18 and 19 OWNER S MANUAL T0130 Common wire optional Factory installed jumper...

Page 13: ... REVERSING VALVE COMPRESSOR Y 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment OWNER S MANUAL Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 T0130 Factory installed jumper betw...

Page 14: ...to 22 gauge unshielded cable from the thermostat to the equipment OWNER S MANUAL Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 T0130 Factory installed jumper between RC and RH FAN G POWER R B REVERSING VALVE...

Page 15: ... units with a separately controlled fan For jumper configuration see pages 18 and 19 OWNER S MANUAL Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 T0130 Factory installed jumper between RC and RH C RH Y W G R...

Page 16: ... units For jumper configuration see page 18 POWER R W GAS OR ELECTRIC HEAT Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 T0130 Factory installed jumper between RC and RH C RH Y W G RC O B Common wire optiona...

Page 17: ... package units For jumper configuration see pages 18 and 19 Remove the factory installed jumper between RC and RH Heating System FAN G W GAS OR ELECTRIC HEAT W GAS OR ELECTRIC HEAT RH POWER HEAT RH POWER HEAT Heating System T0130 Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced pag...

Page 18: ...ge units OWNER S MANUAL Jumper 1 J1 should be set for GAS and Jumper 2 J2 should be set for GAS ELEC for for typical gas furnace heating with electric cooling Jumper 3 J3 is not used T0130 GAS GAS ELEC J1 J2 PCB 00597 Rev AA PCA 00569 Rev O B GAS ELEC HP GAS ELEC HP BAT BAT 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD MODEL T0130 082100009 C RH Y W G RC O B 471 471 471 R16 R18 C11 D7 NNE ACPJA P4S220 5 ...

Page 19: ...a separately controlled fan T0130 Jumper 1 J1 should be set for ELEC HP and Jumper 2 J2 should be set for GAS ELEC for for typical electric heating with electric cooling Jumper 3 J3 is not used ELEC HP GAS ELEC J1 J2 PCB 00597 Rev AA PCA 00569 Rev O B GAS ELEC HP GAS ELEC HP BAT BAT 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD MODEL T0130 082100009 C RH Y W G RC O B 471 471 471 R16 R18 C11 D7 NNE ACPJA ...

Page 20: ...e set for ELEC HP Jumper 2 J2 should be set for HP and Jumper 3 J3 should be set for O for typical heat pump operation Note Thermostat does not have Auxiliary Heat Emergency Heat capability O J3 HP J2 ELEC HP J1 PCB 00597 Rev AA PCA 00569 Rev O B GAS ELEC HP GAS ELEC HP BAT BAT 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD MODEL T0130 082100009 C RH Y W G RC O B 471 471 471 R16 R18 C11 D7 NNE ACPJA P4S22...

Page 21: ...e set for ELEC HP Jumper 2 J2 should be set for HP and Jumper 3 J3 should be set for B for typical heat pump operation Note Thermostat does not have Auxiliary Heat Emergency Heat capability B J3 HP J2 ELEC HP J1 PCB 00597 Rev AA PCA 00569 Rev O B GAS ELEC HP GAS ELEC HP BAT BAT 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD MODEL T0130 082100009 C RH Y W G RC O B 471 471 471 R16 R18 C11 D7 NNE ACPJA P4S22...

Page 22: ...at slide the Mode Switch to COOL Press the COOLER or WARMER buttons until the set temperature is 10 degrees below room temperature The HVAC unit should energize in the cooling mode Page 6 Note You may need to wait up to five minutes for cooling to energize due to the compressor lockout feature Turn on the power to the Heating Air Conditioning system On the thermostat slide the Mode Switch to OFF S...

Page 23: ...SE The cooling setpoint is set too high the Mode Switch is not set for Cool or the batteries are too weak REMEDY Consult the Normal Operation section in this manual to Lower the cooling setpoint Page 6 Correct the Mode Switch position Page 6 Replace the batteries Page 10 OWNER S MANUAL SYMPTOM The fan does not turn on even though the compressor has energized CAUSE The Fan Switch is not completely ...

Page 24: ...heating setpoint is set too high the Mode Switch is not set for Heat or the batteries are too weak REMEDY Consult the Normal Operation section in this manual to Raise the heating setpoint Page 6 Correct the Mode Switch position Page 6 Replace the batteries Page 10 4Z95 P N 88 632 Rev 3 T0130 70 HEAT ...

Page 25: ...R PERSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owner s manual including filter...

Reviews: