manualshive.com logo in svg
background image

 

 
 
 
 
 
 

 

TECHNICAL INFORMATION 

 

 

VERSO+ 
VERSO+ 220 

Versions 1,2 and 4 readers 

Содержание VERSO+ 1

Страница 1: ...TECHNICAL INFORMATION VERSO VERSO 220 Versions 1 2 and 4 readers...

Страница 2: ...ING A POWER LOSS BOLT AND AN ELECTROMAGNETIC DOOR LOCK OPERATING ON POWER LOSS 8 CONNECTING A STANDARD POWER ON DOOR LOCK 9 Connecting a push button and microswitch to the coffret 220 enclosure 10 Con...

Страница 3: ...VERSO unit manufactured by the French company Vauban Systems We thank you for your interest in our products If you want more information about our range please visit our website www vauban systems fr...

Страница 4: ...or Level 2 protected environment of standard NF EN 61000 4 4 This product must be installed by an approved company Incorrect installation and use may result in electric shock or fire Before installati...

Страница 5: ...220V int gr e o Output voltage 12V o Maximum output current 3A et 2A o Battery connection 12V 7Ah dim 151 x 97 5 x 65 mm or 12V 18Ah dim 181 x 167 x 76 mm o Control relay 1A 12V 1A 24V COMPATIBILITY...

Страница 6: ...NOTE Each reader can have different technology e g Reader 1 using Wiegand Reader 2 using Clock Data WARNING If you use an external power supply for your proximity readers take care to connect the vari...

Страница 7: ...ect an RS485 bus INFORMATIONS 2 conductors 2 pairs recommended Max distance 750 m Cable type 0 6 mm SYT recommended WARNING Do not install the cables near other high voltage or high current cables par...

Страница 8: ...er system operation due to back currents it is imperative to use and connect the anti back current diodes supplied with the unit in compliance with the cabling diagram above Even when using an additio...

Страница 9: ...to back currents it is imperative to use and connect the anti back current diodes supplied with the unit in compliance with the cabling diagram above Even when using an additional uninterruptible pow...

Страница 10: ...10 CONNECTING A PUSH BUTTON AND MICROSWITCH TO THE COFFRET 220 ENCLOSURE...

Страница 11: ...11 CONNECTING THE POWER SUPPLY PHASE NEUTRAL EARTH 12V 0V 12V 3A output door release 12V 0V 12V 2A output control unit 12V 0V Battery F3A F4A...

Страница 12: ...is proceed as follows Configure your PC static IP address near of the address range of the unit 192 168 2 xxx Apr s avoir cr votre installation au premier lancement VISOR vous propose de cr er une nou...

Страница 13: ...ed Up to 80 readers VISOR 80 Dongle required Up to 140 readers VISOR 140 Dongle required Up to 840 readers VISOR 840 Dongle required Installation of dongle with the power off install the dongle as sho...

Страница 14: ...ogin is admin and the password is located on the label bonded on the housing You access to the home page According to the number of readers managed a dongle may be required Number of readers in the in...

Страница 15: ...network GND 12V Standby Common Work Repos Common Work 12V 1 5A max GND CLOCK DATA1 A DATA DATA0 B LED GND Push button Door contact Conditional entry CLOCK DATA1 A DATA DATA0 B LED GND Push button Door...

Страница 16: ...LED of Extension bus first activates around 5 seconds To activate the product in DHCP mode wait for the blue LED of Extension bus to blink around 5 seconds then wait for the blue LED to switch on a s...

Страница 17: ...17 FREE INSTALLER HOTLINE DO YOU HAVE ANY TECHNICAL QUESTIONS CONTACT OUR FREE HOTLINE...

Отзывы: