5009a Quick Start Guide 

Step 1:  Power Supply Connection 

You are going to need a 6Vdc ±0.5V at 600mA power supply.  Use the supplied red-black Hirose cable to 

connect to your power supply.  Connect it and you should see two blue LEDs illuminating through the 

label just below the Source 1 and Source 2 label markings.  Your 5009a will now be set to 2440MHz on 

Source 1 and 2480MHz on Source 2. 

See 

“Hints and Kinks – Power Supplies”

 on back of this document. 

Step 2: USB connection 

Connect the provided USB cable to your 5009a and host computer. Your computer should recognize it as 
a new FTDI Virtual Com Port.  If you have trouble, then it is likely you do not have the correct VCP 
(virtual com port) driver.  (Download FTDI CDM v2.12.00 WHQL Certified.zip from the link below, unzip 
and run).   

Step 3: Terminal Program 

You will need a terminal program to change your 5009a settings.  Just about any terminal program will 
work.  We have provided 

5000term.zip

 .   Unzip and running 5000term.exe will automatically find the 

correct Virtual Com Port.  If you use a different terminal program, your port settings are 9600, 8, None, 
1, None.  

Step 4: Synthesizer Settings 

After launching your terminal program, press the Enter key a few times and check to see that you get a 
cursor like this: “-1->”, if you do, you have successfully established communications with your 5009a. 
Type 

help

 to get the help menu  

control-c will exit  program.   
control-f will increase the baud rate to 115200. 
control-r will reset the synthesizer to factor default settings.. 

Consult the 

Valon 5009a Operations Manual

 for more information on the use of these commands. 

Note that as of this date, not all commands in the Operations Manual are available.  As these commands 
become available, we will notify you and you will be able to download the updated *.bin files.  You can 
also use the 5000term.exe terminal program to load the *latest*.bin files.  

For the latest 5009a Downloads:  

 

https://www.valontechnology.com/5009users/5009.htm

 

Above all, if you have trouble or need help just contact us. 