MODEL SS-795
EARLY WARNING
SMOKE & FIRE ALARM
WITH SILENCE CONTROL

Visit Us on the Web!

READ ALL INSTRUCTIONS

The smoke alarm has a recommended service life of at least 10 years under normal conditions.
The smoke alarm uses an extremely small amount of a radioactive element in the ionization
chamber. Do not  tamper with radioactive sealed source or try to repair the smoke alarm
yourself. Refer to instructions for repairs.

SMOKE ALARM LIMITATIONS AND FUNCTIONS

THERE ARE TWO BASIC SMOKE ALARM TYPES - IONIZATION AND PHOTOELECTRIC.
Ionization smoke alarms (such as this Smoke Alarm) are your best overall choice for reliability
and fast response time, since they quickly sense small "invisible" smoke particles and will
also sense larger "visible" smoke particles.  Photoelectric smoke alarms may respond more
quickly in certain types of fires, for example - slow smoldering fires with large "visible" smoke
particles. ALL TYPES OF SMOKE ALARMS HAVE LIMITATIONS. NO TYPE OF SMOKE
ALARM CAN SENSE EVERY KIND OF FIRE OR SMOKE EVERY TIME.

WARNING - SMOKE ALARMS WILL NOT WORK DURING A LOSS OF POWER. SINCE A SMOKE
ALARM WILL NOT WORK WITHOUT POWER, having an alarm(s) that works from two completely
different power sources, such as an AC direct wire with battery backup smoke alarm, can give you an
extra measure of protection in case of an AC power failure or a dead battery.

USING A SMOKE ALARM IN A SMOKY AREA LIKE A KITCHEN, OR IN A HIGH HUMIDITY
AREA NEAR A SHOWER, CAN CAUSE FALSE ALARMS. DO NOT TURN OFF THE AC
POWER TO QUIET THE ALARM. A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT
IS NOT POWERED. Properly locate your alarm to avoid nuisance alarms.

A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY
CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED, VIOLENT
EXPLOSIONS, ESCAPING GAS, IMPROPER STORAGE OF FLAMMABLE MATERIALS,
OVERLOADED ELECTRICAL CIRCUITS, CHILDREN PLAYING WITH MATCHES, NATURAL
CAUSES SUCH AS LIGHTNING, OR ARSON. FIRE PREVENTION IS YOUR BEST
SAFEGUARD.

INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE
RATES, but SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE. Homeowners
and renters alike should continue to insure their lives and properties.

SMOKE ALARMS CANNOT WORK WITHOUT POWER. Battery operated units cannot work if the
batteries are missing, disconnected or dead, if the wrong type of batteries are used or if the batteries
are not installed correctly. AC (only) powered units cannot work if the AC power is cut off for any
reason. If you are concerned about the limitations of battery or AC power, install both types of units.

SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM.
Smoke from fires may not reach the sensing chamber and set off the alarm. One unit should
be installed inside each bedroom or sleeping area.

SMOKE ALARMS MAY NOT DETECT FIRE ON ANOTHER FLOOR OR AREA OF THE
HOME. Recommended minimum protection is at least one unit in every sleeping area and
every bedroom on every level of your home. Interconnected units may provide earlier warning
than stand-alone units since all units alarm when one detects smoke.

SMOKE ALARMS MAY NOT BE HEARD. The alarm horn in this unit meets or exceeds current
UL standards, but it may not be heard if: (1) the unit is located outside a closed or partially
closed door; (2) residents recently consumed alcohol or drugs; (3) the alarm is drowned out
by noise from stereos, TV's, air conditioners or other appliances or (4) if residents are hearing
impaired or sound sleepers.

SMOKE ALARMS ARE NOT FOOLPROOF You must test the unit weekly to ensure your
continued protection. Smoke alarms cannot prevent or extinguish fires.

SMOKE ALARMS HAVE A LIMITED LIFE. The unit should be replaced immediately if it is not
operating properly. You should always replace a smoke alarm after 10 years.

Summary of Contents for SS-795

Page 1: ...OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYINGWITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES but SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties SMOKE ALARMS CANNOTWORKWITHOUT...

Page 2: ...preferred to avoid the thermal barrier that may form at the ceiling When mounting smoke alarm on the ceiling locate it a minimum of 4 10cm from a side wall or corner see Diagram A When mounting smoke alarm on a wall if local codes allow use an inside wall with the top edge of the smoke alarm a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling wall intersections See Diagram A Mobile Ho...

Page 3: ...rical codes in your area Article 760 of the National Electrical Code NFPA 72 101 SBC SBCCI UBC ICBO NBC BOCA OTFDC CABO and any other local or building codes that may apply Wiring and installation must be performed by a licensed electrician Failure to follow these guidelines may result in injury or property damage This unit must be powered by a 24 hour 120V AC 60Hz circuit Be sure the circuit cann...

Page 4: ...be powered from a single AC branch circuit If local codes do not permit be sure the neutral wire is common to both phases The maximum wire run distance between the first and last smoke alarm in an interconnected system is 1 000 feet NOTE Use standard household wire 18 gauge or larger rated at least 300V as required by local codes available at all electrical supply hardware stores Early warning fir...

Page 5: ...ushing the test button on the smoke alarm cover for at least three seconds The smoke alarm will automatically reduce sensitivity and beep every 30 40 seconds for approximately 8 minutes to indicate the alarm is in the temporary silent condition The smoke alarm will gradually reactivate during the 8 minutes and sound the alarm if particles of combustion are still present The silence feature may be ...

Page 6: ...ure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 2 2 1 1 1 Smoke detectors shall be installed outside of each separate sleepin...

Page 7: ...ct to Universal Security Instruments Inc at 7 A Gwynns Mill Court Owings Mills Maryland 21117 postage prepaid with a payment of 4 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN...