background image

 

 FLORIDA-PNEUMATIC.COM 

 

Please contact 1-800-356-3392 for further assistance.

Universal Tool

IMPACTS

General Safety Information & Replacement Parts

WARNING:

 Risk of injury to persons. Read and 

understand operation instructions.  Always become familiar 
with all the instructions and warnings before operating any 
pneumatic tool.

TABLE OF CONTENTS

General Safety Information    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Air Compressor and Air Tool Safety  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-3 
Tool Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Maintenance / Lubrication   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Operation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Troubleshooting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Warranty   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Service Parts  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7 

UT8120R 

1/2" Compact Pistol Impact Wrench

WARNING

:

 This product contains chemicals known to 

the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling.

WARNING

:

 This product contains lead, a chemical known to 

the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling.

Summary of Contents for UT8120R

Page 1: ...Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6 Warranty 6 Service Parts 7 UT8120R 1 2 Compact Pistol Impact Wrench WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling WARNING This produc...

Page 2: ... used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis risk assessment of these hazards and implementation of appropriate controls of is essential Risk assessment should include dust created by the use of the tool and the potential for disturbing existing...

Page 3: ...sks that are specifically designed to filter out microscopic particles Important Warnings Impacts Specifications 1 Eye protection and hearing protection and safety gloves must always be worn when operating an impact wrench or impact driver 2 When using heavy impact sockets or sockets on impact wrenches with 3 4 drive anvils or larger a socket retaining ring and pin should be used to prevent the so...

Page 4: ...rottle is accidentally engaged LUBRICATION An in line filter regulator lubricator is recommended as it increases tool life and keeps the tool in sustained operation Regularly check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exhaust ports and holding the throttle open approximate...

Page 5: ...d The position with the smallest circle has the least amount of power and the position with the largest circle has the most amount of power The settings on the regulator are only for reference and do not denote a specific power output 4 Tightening loosening the bolts or fasteners Place the rotation push button located above the trigger of the impact wrench to the correct direction Push the button ...

Page 6: ...icate the tool according to the lubrication instructions in this manual The air pressure is low Adjust the regulator on the tool to the maximum setting Adjust the compressor regulator to the tool s maximum setting of 90 psi The air hose leaks Tighten and seal the hose fittings with pipe thread tape if leaks are found The air pressure drops Ensure the hose is the proper size Long hoses or tools usi...

Page 7: ... 9612830 1 ROTOR 1 8 9328825S WASHER 1 29 9612831C BLADE 6 9 9638010 RETAINER RING 1 30 9612832 FRONT PLATE 1 10 9612811 AIR CONNECTING 1 31 9B6001Z BALL BEARING 1 11 9638011 SPRING PIN 1 32 9612834 HAMMER FRAME 1 12 9612847 SPRING PIN 1 33 9612835 HAMMER 2 13 9OR2512 O RING 1 34 9612836 HAMMER PIN 2 14 9612814 TRIGGER 1 35 9612837 ANVIL 1 15 9612817 O RING 1 36 9OR7718 O RING 1 16 9612818 1 VALVE...

Page 8: ...umatic Manufacturing Corporation 851 Jupiter Park Lane Jupiter FL 33458 Universal Tool Questions problems missing parts Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 FLORIDA PNEUMATIC COM Retain this manual for future use ...

Reviews: