background image

852927D-0503J

• Please read this entire manual before installation and use of

this appliance. Failure to follow these instructions could result

in property damage, bodily injury, or even death.

Contact  your  local  building  or  fire  officials  about  obtaining

permits, restrictions and installation inspection requirements in

your area.

• Save these instructions.

If your heater is not properly installed, a house fire may result.

For everyone’s safety, follow all Installation and Operating

Directions. Never use makeshift compromises during the

installation of this appliance. Contact your local building

or  fire  officials  about  restrictions  and  installation  inspection

requirements in your area.

U.S. Environmental Protection Agency 

Certified to comply with 2020 

particulate emissions standards.

MODEL: VG5780

SAVE THESE INSTRUCTIONS

THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU 

TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de 

carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et 

des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de 

renseignements, veuillez consulter le site www.P65warnings.ca.gov

United States Stove Company

PO Box 151, 227 Industrial Park Rd.,

South Pittsburg, TN 37380

PH: (800) 750-2723

www.usstove.com

Report #: F19-550

Certified  to  ASTM  E1509-12  (2017),  and 

Certified to ULC S627, 2000, 

 

This unit is not 

intended to be used as a primary 

source of heat. 

R

Summary of Contents for VOGELZANG VG5780

Page 1: ...STRUCTIONS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE CALIFORNIA PROPOSIT...

Page 2: ...to repair or replace any part of the stove unless instructions for doing so are given in this manual All other work should be done by a trained technician Do not operate your stove with the viewing d...

Page 3: ...Your pellet stove is designed to burn premium hardwood pellets that comply with the Pellet Fuel Institute PFI minimum of 40 lbs density per cubic ft 1 4 to 5 16 diameter length no greater than 1 5 no...

Page 4: ...de Wall to Vent Pipe 12 305 C Back Wall to Stove 12 305 D Back Wall to Vent Pipe 3 77 E Ceiling to Floor 84 2134 F Ceiling to Stove 46 875 1191 CORNER CLEARANCES G Side Wall to Stove 10 254 H Side Wal...

Page 5: ...tions PELLET VENT TYPE A UL listed 3 inch or 4 inch type PL pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the stove use a 3 inch t...

Page 6: ...grade when adjacent to public walkways E Minimum 2 foot 0 61m clearance above any grass plants or other combustible materials F Minimum 3 foot 0 91m clearance from an forced air intake of any applianc...

Page 7: ...ire harnesses as shown Step 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely Step 3 Connect the factory installed wiring harnesses to the control panel as...

Page 8: ...on can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the sno...

Page 9: ...e floor to your stoves inlet exhaust pipes are approximate and may vary depending on your installation TYPICAL FRESH AIR TERMINATION EXHAUST INLET LOCATIONS OUTSIDE AIR SUPPLY OPTIONAL UNLESS INSTALLI...

Page 10: ...n changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled with a Thermostat Separate LEDs to the...

Page 11: ...troduced by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke Do not burn wet pellets The stove s performance depends heavily on the q...

Page 12: ...e towards the right Through trial and error you will find the best setting Consult your dealer if you need help NOTE On heat range 1 damper should be either completely closed or open no more than a 1...

Page 13: ...ed with a brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be prof...

Page 14: ...lower front corners of the heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to the firebox with 2 5 16 screws Remove the clean outs and vacuum out...

Page 15: ...smoke and CO monitors in areas having the potential to generate CO CHECK AND CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust fines that is building up in the feed s...

Page 16: ...ake sure that they are working properly This is also a good time to give the entire stove a good cleaning throughout SPRING SHUTDOWN After the last burn in the spring remove any remaining pellets from...

Page 17: ...ons to operate this wood heater in a manner inconsistent with operating instructions in this manual Trouble Shooting Guide Display is Flashing E1 Possible Causes Possible Remedies Unplug stove first w...

Page 18: ...the gray wires to the air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blo...

Page 19: ...n then remove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to rem...

Page 20: ...r for secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing th...

Page 21: ...ll Coming Back Into The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with...

Page 22: ...jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and connectors c...

Page 23: ...Remove the burnpot and thoroughly clean it Air damper is broken Visually inspect the damper assembly Make sure the damper plate is attached to the damper rod When the damper rod is moved the plate sho...

Page 24: ...24 Replacement Parts 1 5 2 7 8 28 29 30 31 32 9 11 10 16 13 12 14 15 18 17 23 25 24 26 33 27 20 19 21 22 3 4 6...

Page 25: ...haust 1 11 892187 Auger 1 12 891132 Auger Bushing 1 13 892776 Vented Back Panel 1 14 80709 Convection Blower 1 15 80455 High Limit T disc 1 16 80549 Vacuum Switch 1 17 80602 Exhaust Blower 1 18 88166...

Page 26: ...26 Wiring Diagram 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Page 27: ...27 Notes...

Page 28: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Page 29: ...S UN ENDROIT SUR POUR VOUS Y REFERER LORSQUE VOUS NOUS CRIVEZ VEUILLEZ INDIQUER LE NUM RO COMPLET DU MOD LE AFFICH SUR LA PLAQUE SIGNAL TIQUE DE L APPAREIL DE CHAUFFAGE LORSQUE VOUS COMMANDEZ DES PIEC...

Page 30: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 31: ...26 1 25A 250V Fusible 7 5A 250V Fusible Sch ma De C blage CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr...

Page 32: ...1 12 891132 Douille de vis sans fin 1 13 892776 Panneau arri re ventil 1 14 80709 Ventilateur convection 1 15 80455 Disque T haute limite 1 16 80549 Commutateur de vide 1 17 80602 Ventilateur d chappe...

Page 33: ...24 Pi ces De Rechange 1 5 2 7 8 28 29 30 31 32 9 11 10 16 13 12 14 15 18 17 23 25 24 26 33 27 20 19 21 22 3 4 6...

Page 34: ...utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des bois diff rents pr...

Page 35: ...tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par vider la tr mie...

Page 36: ...ande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v rifiez le c blage...

Page 37: ...testeur de continuit pour tester l interrupteur de s curit de la tr mie remplacer le si n cessaire L arbre de la tari re est coinc Commencez par vider la tr mie Puis retirez le moteur de la tari re en...

Page 38: ...le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le support du tube de ta...

Page 39: ...ateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce doit tre la te...

Page 40: ...rchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit d fectue...

Page 41: ...saison de chauffage v rifiez que la zone l ext rieur des syst mes d vacuation et d admission d air ne soit pas obstru e Nettoyez et retirez les cendres volantes du syst me d vacuation Nettoyez tous l...

Page 42: ...diam tre JOINTS DE PORTE ET DE VITRE Inspecter r guli rement les principales portes et fen tres en verre joints La porte principale peut avoir besoin d tre enlev pour avoir des joints effiloch s bris...

Page 43: ...oins avant inf rieurs de l changeur de chaleur Pour acc der ces outs propres vous devez retirer les deux panneaux lat raux Les sorties propres sont fix es la chambre de combustion avec 2 vis 5 16 Reti...

Page 44: ...arri re ou d ouvrir le syst me d vacuation pour toute t che d inspection de nettoyage ou d entretien Ne proc dez jamais l inspection au nettoyage ou l entretien sur un po le chaud N utilisez pas le p...

Page 45: ...re vers la gauche En r gle g n rale en cas de r glage pour une faible vitesse d alimentation le registre doit tre r gl vers la gauche dans le sens de fermeture Pour une vitesse d alimentation lev e le...

Page 46: ...lation des codes du b timent pour lesquels le po le a t approuv et cela annulerait toutes les garanties La conception du po le int gre l alimentation automatique des granul s dans le feu selon un ryth...

Page 47: ...rres passant du niveau 1 au niveau 5 de chauffage C TOUCHE C F La touche C F fait passer l affichage deux chiffres des degr s Celsius aux degr s Fahrenheit et vice versa D TOUCHE MODE M T Le Mode de f...

Page 48: ...aussi court et rectiligne que possible et doit s adapter par dessus et non pas l int rieur du branchement d air ext rieur du po le CONDITIONS SPECIALES D INSTALLATION DANS UNE MAISON MOBILE Avertisse...

Page 49: ...ction de nettoyage et un tuyau vertical l int rieur jusqu au niveau du sol Avec cette installation il faut tenir compte de la ligne de cong re des herbes et des feuilles mortes Nous recommandons une l...

Page 50: ...de toiture ou surplombs H D gagement minimum de 1 pi 0 3 m l horizontale de tout mur en mat riau combustible I Doit se trouver au minimum 3 pi 0 91 m au dessus du toit et 2 pi 0 61 m au dessus de tout...

Page 51: ...si l installation se trouve plus de 2 500 pi 762 m d altitude Nous recommandons l utilisation de conduits Simpson Dura Vent ou Metal Fab si vous utilisez d autres tuyaux consultez les codes de constr...

Page 52: ...gistre de tirage sur le syst me d vacuation de cet appareil Les directives d installation ci dessous doivent tre respect es pour garantir la conformit tant avec la liste de s curit de ce po le qu avec...

Page 53: ...fabricant ne pourra tre tenu pour responsable des dommages caus s par le mauvais fonctionnement d un po le d une mauvaise vacuation ou installation Pour toute question appelez le 800 750 2723 et ou c...

Page 54: ...ourrait provoquer un incendie de maison Ne pas sur le feu ou utiliser des combustibles volatiles ou combustibles cela peut causer un danger de dommages personnels et mat riels SECURITE ET CONFORMITE E...

Page 55: ...pas enti rement l alimentation des composants lectriques du po le Ne tentez jamais de r parer ou de remplacer une pi ce du po le sauf indication contraire dans les directives de ce guide Tous les aut...

Page 56: ...reil n a pas t con u pour tre utilis en tant que source principale de chaleur Certifi selon la norme ASTM E1509 12 2017 et Certifi ULC S627 2000 et UM 84 HUD US Environmental Protection Agency Certifi...