Summary of Contents for UTT-110B Series

Page 1: ...way SIP User manual Copyright 2013 Shenzhen Ultrative Technologies Co Ltd All rights reserved 1 UTT 110B Series VOIP Gateway SIP User manual VER 1 0 All manuals and user guides at all guides com a l l...

Page 2: ...improve at any time the products mentioned and the manual itself without prior noticing This document contains proprietary intellectual property rights owned by Shenzhen Ultrative Technology Co Ltd al...

Page 3: ...1 Connection to LAN by Static IP or DHCP 10 2 6 2 As a proxy server is responsible for dial up Internet 10 2 7 NETWORK ACCESS CONFIGURATION 11 2 8 LOG IN TO THE WEB CONFIGURATION INTERFACE 11 PART II...

Page 4: ...PORT IP INQUIRY AND CONFIGURATION 32 4 2 LAN PORT IP INQUIRY AND CONFIGURATION 33 4 3 INQUIRY PHONE NUMBER OF THE PORT 33 PART FIVE TYPICAL APPLICATION CONFIGURATION 16FXS 16FXO 33 5 1 CONFIGURATION O...

Page 5: ...et Readers The target readers of this manual includes I T Engineer Sales Engineer NOC 1 3 About the content UTT 110BSeries VOIP Gateway SIP User manual offers detailed hardware specifications installa...

Page 6: ...be used in where VoIP communication is required 2 1 Characteristics of UTT 110B Series VOIP Gateway Carrier class reliability Support Efforts to improve fault detection network alarm functions Low Po...

Page 7: ...tralized network management device Web based network management support equipment Powerful QoS guarantee Based on IPv4 Tos and DiffServ support services to ensure the voice priority Support IEEE802 1P...

Page 8: ...LAN 10 100Base T RJ 45 for PC Auto MDIX Power Consumption Idle 4 W full load 6W Operating Temperature 5 50 Relative Humidity 5 95 non condensing The main chip 5VT 1310 DSP 5VT 1310 CODEC ZL88601 Flas...

Page 9: ...the power supply for the long bright state 1 2 Port work light off hook ringing the lights are flashing during a call the standby is off Table 2 3 Rear panel connectors and LEDs The rear panel connec...

Page 10: ...ies integrated access devices connected to the hub or switch as shown in Figure 2 3 3 WAN port based on the local area network environment using PPPoE dial up mode dynamically obtain IP DHCP or static...

Page 11: ...ed the computer and UTT 110B Series Voice over IP integrated access device s LAN port to connect to a hub or switch with a network cable network cable can also be used to connect directly to the compu...

Page 12: ...n be integrated Voice over IP devices and UTT 110B the series C ping 192 168 11 1 Pinging 192 168 11 1 with 32 bytes of data Request timed out Request timed out If the above message appears it means t...

Page 13: ...enzhen Ultrative Technologies Co Ltd All rights reserved 13 Figure2 6 WEB Login Interface User Name admin Password admin Default Username admin passowrd admin Click Enter then Figure 2 4 WEB Setting i...

Page 14: ...ode rfc2833 use Default value 101 a limited range of values from 97 to 101 Default the parameters to be consistent with the peer device but it can also auto negotiation RTP start port Min sending and...

Page 15: ...e the ring pattern Mode 1 1 S pass 4S off Mode 2 2 S pass 4S off model 3 0 5 S pass through 0 5S 5S 4S broken off Mode 4 1 S can be modified throughthe drop down 3S off Normal ringing mode Mode 1 1S p...

Page 16: ...tion items Description Host name Names can configure the device the device defaults to the hostname SIP AG the user name of the device can be configured as required MAC address Display the MAC address...

Page 17: ...address Default 0 0 0 0 this can be modified in the preferred DNS server address Secondary DNS address DNS server is turned on the default secondary DNS addresses 0 0 0 0 this can be modified alterna...

Page 18: ...tions use is not recommended to use Media triple PRECEDENCE Media QOS mode is selected as three TOS the signaling three PRECEDENC default value is 0 the effective range of values 0 7 IP precedence 6 a...

Page 19: ...s from that address End IP address pool After the DHCP server is turned on connected to the LAN port of the network terminal in front of the address to obtain IP Lease Term IP address lease duration t...

Page 20: ...ed on when the DMZ function is turned on fill in this DMZ address Port Mapping In the NAT feature is turned on turned off when the DMZ port mapping is enabled by default turned off turned on drop down...

Page 21: ...default value 600 the actual registration refresh time and softswitch negotiation rport The default value is off select Open with rport required field Heartbeat switch Heartbeat off do not send a hea...

Page 22: ...set users can go to Port Settings Basic Settings to choose the one to activate as shown below Figure3 7 Call Path Setting Interface By Clicking Edit User can check the detailed rules call rules are c...

Page 23: ...le 3 7 Call rule configuration increases Increased call rule configuration items Explanation DigitMap Called number matching rules IP Routing The purpose of routing IP address the default value0 0 0 0...

Page 24: ...after the number of 602 Note A number may be a need to remove the direct conversion of d followed by d without adding deletecontent C c hange to change the rules on the inside callnumbers such as the...

Page 25: ...of the port output volume Do Not Disturb switch When turned on the port open DND closed shut down the port Disturb feature Call waiting switch When turned on the port open call waiting function Whenc...

Page 26: ...ed from the drop down menu Caller ID conversion With the call path changeover switch inside the calling number to use after opening the calling number to fill in this transformation rules transformati...

Page 27: ...displays the number of the remote number Reverse polarity Support The default value is off reverse polarity signal when turned on the phone is turned on when the port will provide anti polarity signal...

Page 28: ...Ringing voltage The default value of 90 unit V the effective range of0 90V 3 6 phone number setting Sign in web configuration interface select phone number setting for setting the phone number as the...

Page 29: ...number Register option Select Yes or No Prefix Default represent any prefix Accept IP Default represent any IP Port selection Select the port one port number can band multiple port and realize one num...

Page 30: ...Select the right backup file and restore the configuration data for this equipment Restart option Reset reset the equipment Factory reboot restore the default factory setting and restart the equipmen...

Page 31: ...ct Taiwan Japan Korea United States Germany Russia and etc Progress tone receive setting Setting the receive progress tone for FXO port Default Default value is China can select China Taiwan Japan Sou...

Page 32: ...C address IP address subnet mask Start of DHCP IP pool End of DHCP IP pool Active DHCP clients Route information Show NAT start state Turn on or Turn off Part 4 IVR inquiry and IP address configuratio...

Page 33: ...5 0 can set to actual required subnet mask 4 3 Inquiry phone number of the port When hearing dialing tone or busy tone after phone off hook type the following function code 300 inquiry phone number of...

Page 34: ...Ultrative Technologies Co Ltd All rights reserved 34 Figure 5 1 phone number configuration 2Click Delete Button delete all the default number in FXO port as following figure Figure 5 2 Figure 5 2 Dele...

Page 35: ...phone number 9 and select all the FXS port to the group of phone number 9 select FXO as port type as following figure Figure 5 4 Figure 5 4 Add phone number Figure 5 5 Add Phone number 4 After submit...

Page 36: ...fault item as following figure Figure 5 7 Figure 5 7 Edit call path 6Click add call rules button add a call rule 9 with route IP 127 0 0 1 Terminal loopback and click submit button as following figure...

Page 37: ...ipment The out number is 9 and this out number can be amended according to actual requirement In this scene we band number 9 to all the FXO port for the equipment and form to a group for number 9 You...

Page 38: ...cess is as follows 1 select Phone number setting view the number in current FXS port as following figure figure5 12 Figure 5 12 view the number 2 According to the above figure the number in FXS port i...

Page 39: ...All rights reserved 39 Figure 5 13 Port setting 3 click basic setting button on port 9 select turn on for hotline and write 6001 in hotline No field 6001 is the tel number configured in port 1 select...

Page 40: ...PSTN number connected to FXO port through the PSTN number the S port telephone in corresponding hotline will ring and after off hook in S port normal talk with the telephone in PSTN side is ok Scene S...