background image

24 GHz Full Duplex 

Point-to-Point 2 Gbps Radio

Model: AF-24HD

Summary of Contents for AF-24HD-EU

Page 1: ...24 GHz Full Duplex Point to Point 2 Gbps Radio Model AF 24HD ...

Page 2: ......

Page 3: ...t Carriage Bolts Qty 4 Flat Washers Qty 4 Split Lock Washers Qty 4 Hex Nuts Qty 4 Metal Strap 24 GHz Full Duplex Point to Point 2 Gbps Radio Model AF 24HD External GPS Antenna Cable Ties Qty 3 Gigabit PoE Adapter 50V 1 2A Power Cord Quick Start Guide TERMS OF USE Ubiquiti radio devices must be professionally installed Shielded Ethernet cable and earth grounding must be used as conditions of produc...

Page 4: ...2 Hardware Overview Side 0 5 10 5 10 Alignment Bracket Elevation Adjustment Azimuth Adjustment Ground Bonding Point Lock Bolts Lock Bolts airFiber AF 24HD Quick Start Guide ...

Page 5: ...3 Back Lock Bolts Lock Bolts Lanyard Loop Lanyard Loop Azimuth Adjustment Lock Bolts Lock Bolts Cover Lock Port Cover Elevation Adjustment Hardware Overview ...

Page 6: ... the unit is powered on DATA 10 100 1000 Mbps port handles all user traffic AUX Port for audio tone aiming LED Display Digital display used for power status and mode information CONFIG 10 100 Mbps secured port for configuration By default this is the only port that can monitor configure and or update firmware LEDs Link Act Speed GPS Modulation Link Act Speed RX Power Master Slave RF Link Status ai...

Page 7: ...O Long Flash 6x 64QAM MIMO On 8x 256QAM MIMO LED Display RX Power dBm Number Decodable RX Signal Flashing Number Undecodable RX Signal Overload Condition Master Slave Off Slave Mode On Master Mode RF Link Status Off RF Off Short Flash Syncing Normal Flash Beaconing Long Flash Registering On Operational CONFIG Speed Off 10 Mbps On 100 Mbps Link Act Off No Ethernet Link On Ethernet Link Established ...

Page 8: ...WARNING Failure to properly ground your airFiber units will void your warranty Recommended 2 Outdoor Gigabit PoE surge protectors Ubiquiti Ethernet Surge Protector model ETH SP Note For guidelines about grounding and lightning protection follow your local electrical regulatory codes Outdoor shielded Category 5e or above cabling and shielded RJ 45 connectors should be used for all wired Ethernet co...

Page 9: ...t an Ethernet cable between your computer and the CONFIG port Configure device settings in the airFiber Configuration Interface Once configuration is complete disconnect the cables to move the airFiber radios Reconnect at the site After you have mounted the airFiber radios establish and optimize the RF link Connecting Power over Ethernet 1 Turn the Cover Lock to the Unlocked icon Slide the Port Co...

Page 10: ... end of the Ethernet cable from the DATA port to the Ethernet port labeled POE on the Gigabit PoE Adapter 4 Connect the Power Cord to the power port on the Gigabit PoE Adapter Connect the other end of the Power Cord to a power source airFiber AF 24HD Quick Start Guide ...

Page 11: ...ost of higher latency and throughput Full duplex operation provides the highest throughput and lowest latency however you have fewer frequency management options Half Duplex default The TX and RX Frequencies can be the same or different to suit local interference TX RX TX Slave Master Frequency A Frequency A RX Half Duplex Diagram Full Duplex The TX and RX Frequencies should be different TX RX TX ...

Page 12: ...h your web browser Type http 192 168 1 20 in the address field and press enter PC or return Mac https 192 168 1 20 4 The login screen will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to the U S Country Code to ensure compliance with FCC regulations airFi...

Page 13: ...lave c For the Duplex drop down Half Duplex The default mode The TX and RX Frequencies can be the same or different to suit local interference Full Duplex The TX and RX Frequencies should be different d Select a TX Frequency This must match the RX Frequency of your other airFiber AF 24HD e Select a RX Frequency This must match the TX Frequency of your other airFiber AF 24HD f If needed change the ...

Page 14: ...Apply 9 In Band Management is enabled by default so each airFiber radio must have a unique IP Address If the airFiber radios use the same IP Address then you may lose access to the airFiber radios via the DATA ports To change the network settings a Click the Network tab b Change the IP Address Netmask and other settings to make them compatible with your network c Click Change and then click Apply ...

Page 15: ...e The mounting assembly can accommodate a Ø 51 101 mm 2 0 4 0 pole a Orient the Pole Mount Bracket around the pole so it is aimed in the direction of the other airFiber AF 24HD b Insert the Carriage Bolts into the Pole Clamps c Secure the clamps with the Flat Washers Split Lock Washers and Hex Nuts Note orientation of slots Aim towards link Hardware Installation ...

Page 16: ...remove the eight Lock Bolts located on the Alignment Bracket 4 Ensure that there is a 6 mm gap between the head of each M8x14 Serrated Flange Screw and the Alignment Bracket 0 5 10 5 10 6 mm airFiber AF 24HD Quick Start Guide ...

Page 17: ...ur M8x14 Serrated Flange Screws with the slots on the Pole Mount Bracket Seat the screws in the slots Securely tighten the screws WARNING To prevent injury ensure that all four screws are seated and fully tightened 0 5 10 5 10 Hardware Installation ...

Page 18: ...d replace the nut to secure the wire c Secure the other end of the ground wire to a grounded mast pole tower or grounding bar WARNING Failure to properly ground your airFiber units will void your warranty Note The ground wire should be as short as possible and no longer than one meter in length airFiber AF 24HD Quick Start Guide ...

Page 19: ...clear view to the sky and is above and as far away as possible from the AF 24HD 1 Attach the GPS Antenna Mount to a pole using the included Metal Strap or attach it to a wall using the appropriate fasteners not included 2 Place the magnetic External GPS Antenna on the mount Hardware Installation ...

Page 20: ...l GPS Antenna to the mount with a Cable Tie 4 Turn the Cover Lock counterclockwise to the Unlocked icon Slide the Port Cover down to remove it 5 Connect the External GPS Antenna to the GPS SMA connector airFiber AF 24HD Quick Start Guide ...

Page 21: ...2 Create a strain relief for the Ethernet cable by feeding a Cable Tie through the tie slot under the cable Then wrap the Cable Tie around the cable and tighten 3 Connect the other end of the Ethernet cable from the DATA port to the Ethernet port labeled POE on the Gigabit PoE Adapter Connecting Ethernet ...

Page 22: ...r end of the Power Cord to a power source Note For added protection we recommend installing two surge surpressors such as the Ubiquiti Ethernet Surge Protector model ETH SP Install the first surge protector within one meter of the airFiber DATA port and install the second surge protector at the ingress point of the location housing the wired network equipment airFiber AF 24HD Quick Start Guide ...

Page 23: ...tors installed 0 5 10 5 10 Ground to Pole Tower or Grounding Block Max 1 m from Ground Bonding Point External GPS Antenna Max 1 m Outdoor Gigabit PoE Surge Protector ETH SP Outdoor Gigabit PoE Surge Protector ETH SP EdgeRouter Gigabit PoE Adapter Power Source Connecting Ethernet ...

Page 24: ...ached to your airFiber radios You may need to use additional hardware to compensate for issues such as the improper orientation of a mounting pole or significant elevation differences between the airFiber radios Establishing a Preliminary Link Adjust the positions of the Master and the Slave to establish a preliminary link This requires the Master and Slave to be within a few degrees of the line o...

Page 25: ... a Loosen the Hex Nuts b Adjust the Pole Mount Bracket and Pole Clamps c Tighten the Hex Nuts 0 5 10 5 10 Hex Nuts 4 Slave Aim the Slave at the Master to achieve the strongest received signal level on the Slave s numeric LED Display which is located next to the CONFIG port If necessary adjust the Slave s position on the pole Slave RF Power dBm Note Values on the LED Display are displayed in negati...

Page 26: ...Adjustment Bolt of the Master through its adjustment range Master Azimuth AZ Adjustment Bolt b Sweep the Elevation EL Adjustment Bolt of the Master through its adjustment range Master Elevation EL Adjustment Bolt Master RF Power dBm Note If the LED Display indicates an overload condition refer to the following section Adjusting RX Gain airFiber AF 24HD Quick Start Guide ...

Page 27: ...8 ft and 800 m 2 625 ft Target 40 dBm Decrease RX Gain to overcome overload condition For short ranges or strong signal conditions adjust the power to be 3 5 dB below overload condition Decrease RX Gain first Never mitigate overload condition by misaligning antennas Link Distance RX Gain Setting Approximate TX Power Setting d 1 km d 3 281 ft High 25 dBm 0 5 km d 1 km 1 640 ft d 3 281 ft Low 19 25 ...

Page 28: ...ther installer sees the strongest received signal level displayed on the LED Display of the Slave 3 Repeat steps 1 and 2 until you achieve a symmetric link with the received signal levels within 1 dB of each other This ensures the best possible data rate between the airFiber radios 4 Lock the alignment on both airFiber radios by tightening all eight Lock Bolts on the Alignment Bracket 5 Observe th...

Page 29: ...ace and audio tone methods The User Guide is available at www ubnt com download airfiber Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements The Frequencies and Output Power fields are provided to the professional installer to assist in mee...

Page 30: ...ndwidth 100 MHz Max Power Consumption 50W Power Supply 50V 1 2A PoE Gigabit Adapter Included Power Method Passive Power over Ethernet 42 58VDC Certifications CE FCC IC Mounting Pole Mount Kit Included Operating Temperature 40 to 55 C 40 to 131 F Integrated Split Antenna TX Gain 33 dBi RX Gain 40 dBi Beamwidth 3 5 Front to Back Ratio 70 dB Polarity Dual Slant Polarization Cross Polarity Isolation 2...

Page 31: ...ded only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b The equi...

Page 32: ...ives or as approved by Ubiquiti Networks in writing II has been painted rebranded or physically modified in any way III has been damaged due to errors or defects in cabling IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no ...

Page 33: ...RPOSE AND NON INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NETWORKS NOR ITS THIRD PARTY PROVIDERS CONTROL BUYER S EQUIPMENT OR THE TRANSFER OF DATA OVER COMMUNICATIONS FACILITIES INCLUDING THE INTERNET AND THAT THE PRODUCTS AND SERVICES MAY BE SUBJECT TO LIMITATIONS ...

Page 34: ...nties or conditions so the above exclusion may not apply to you You may have other rights that vary from country to country state to state or province to province Some countries states and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages so the above limitation may not apply to you EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW THESE WARRANTY TERMS...

Page 35: ...en the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the i...

Page 36: ...ation Dish antenna TX Gain 33 dBi CAN ICES 3 A NMB 3 A Le présent appareil est conforme aux CNR d ISDE Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionn...

Page 37: ...ser may be required to take adequate measures CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it This equipment is intended to be accessed only by service personnel and or trained professionals Country List AT BE BG CY CZ DE DK EE EL ES FI FR HR HU IE IT LV LT LU MT NL PL PT RO SE SI SK UK BFWA Broadband Fixed Wireless Access...

Page 38: ...here you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Verantwortung diese...

Page 39: ...tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre ancien é...

Page 40: ...ration of conformity is available at the following internet address www ubnt com compliance Eesti keel Estonian Käesolevaga deklareerib UBIQUITI NETWORKS et käesolev raadioseadme tüüp AF 24HD vastab direktiivi 2014 53 EL nõuetele ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil www ubnt com compliance Suomi Finnish UBIQUITI NETWORKS vakuuttaa että radiolaitetyyp...

Page 41: ...adiowego AF 24HD jest zgodny z dyrektywą 2014 53 UE Pełny tekst deklaracji zgodności UE jest dostępny pod następującym adresem internetowym www ubnt com compliance Português Portuguese O a abaixo assinado a UBIQUITI NETWORKS declara que o presente tipo de equipamento de rádio AF 24HD está em conformidade com a Diretiva 2014 53 UE O texto integral da declaração de conformidade está disponível no se...

Page 42: ......

Page 43: ......

Page 44: ... trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries All other trademarks are the property of their respective owners Support help ubnt com Community community ubnt com Downloads downloads ubnt com 640 00152 03 640 00152 03 w w w u b n t c o m Ubiquiti Networks Inc 685 Third Avenue 27th Floor New York NY 10017 USA ...

Reviews: