background image

496349 Issue 1

1 of 10

1081/1082

Installation Guide

Compatible Equipment

All hardwired control panels, for example:
808

8-12 zone control panel

816

8-16 zone control panel

8136

8-8136 zone control panel

Summary of Contents for 1081

Page 1: ...496349 Issue 1 1 of 10 1081 1082 Installation Guide Compatible Equipment All hardwired control panels for example 808 8 12 zone control panel 816 8 16 zone control panel 8136 8 8136 zone control panel ...

Page 2: ... limit coverage to the area requiring protection Two sets of relay contacts are provided The alarm contacts are Single Pole Change over in alarm NO C NC and the tamper contacts are closed with the cover on The detectors also provide a Remote LED Enable Disable function which if held high will inhibit the operation of the alarm LED in the Day mode unless a 0V supply is applied to terminal 7 on the ...

Page 3: ...floor Figure 1 1081 Wide Angle 1082 Long Range 30 5m 10 angle at 2 5 3 65m from floor Figure 2 1082 Long Range Operating Temp 10 C to 55 C MW Range Adjustable 100 30 by potentiometer Microwave Dielectric Resonant Oscillator with microstrip antenna 10 687 GHz 1081 1082 Technical Specification ...

Page 4: ...e posi tioned 0 5m above and 2m in front of the detector will not reduce detector performance With tube switched on for one minute then off for 30 seconds a total of five times the detector will not alarm LED Indicators Red LED selectable for unit Alarm Trouble Green LED for PIR detection Yellow LED for MW detec tion Mounting Quick start screw facility for flat wall mounting Provision for corner m...

Page 5: ...vice 8 After all connections are complete seal wire entry openings and apply power to the detector PIR Lens Adjustment This adjustment can only be carried out with the detector cover removed Particular attention should be paid to the lens adjustment procedure for 1082 detectors due to the long range of the detector 1 Squeeze the lens carrier handles and remove the lens carrier from the pcb assembl...

Page 6: ...If necessary adjust the PIR surveillance pattern by loosening the lens clamps on the lens carrier and turning the lens in the appropriate direc tion within the carrier Ensure that the lens clamps are tightened before retesting the lens pattern Note Where the optional wall mounting bracket is used the complete detector pattern PIR and MW can be adjusted 6 On completion of the lens adjustment remove...

Page 7: ...l all LEDs are extin guished 5 Walk into the protected area and stop when the yellow MW LED illuminates Mark this position 6 Repeat steps 4 and 5 in other parts of the protected area until the microwave pattern has been satisfactorily mapped 7 If necessary increase the microwave sensitivity until the area is com pletely covered PIR Surveillance 1 Remove the detector cover and lens carrier assembly...

Page 8: ...ity requirement 1 Remove the detector cover and lens carrier assembly 2 Position the links according to requirements as follows trbl link fitted Red Alarm LED will flash in the event of a failure of the microwave sensor Trouble output operates trbl link not fitted No LED indication of microwave sensor failure Trouble output still operates Test link fitted This link should only be fitted during tes...

Page 9: ...rm locate the cause and correct it Note When walk testing cross the sensitive zones at right angles in an upright position After each activation wait until the LEDs have extinguished Fault Finding Alarm LED does not illuminate during testing Test jumper not fitted correctly Check Test jumper Detect not set for Walk Test Check that panel is set for Walk Test or switch is in Walk Test position if us...

Page 10: ...10 of 10 496349 Issue 1 1081 1082 ...

Reviews: