background image

TSUJI ELECTRONICS CO.,LTD

3739 Kandatsu-machi Tsuchiura-city

Ibaraki-Pre 300-0013 Japan

Phone +81-(0)29-832-3031

Fax    +81-(0)29-832-2662

URL  http://www.tsujicon.jp

E-mail  [email protected]

APPLICATION

OF

ELECTRONIC

DEVICES

2ch ENCORDER COUNTER and 8~16ch COUNTER TIMER

CT08-ER2, CT16-ER2

USER'S MANUAL

4058,4033 (Rev3)

Summary of Contents for CT08-ER2

Page 1: ...ty Ibaraki Pre 300 0013 Japan Phone 81 0 29 832 3031 Fax 81 0 29 832 2662 URL http www tsujicon jp E mail info2 tsuji denshi co jp APPLICATION OF ELECTRONIC DEVICES 2ch ENCORDER COUNTER and 8 16ch COU...

Page 2: ...xx to yy counter 00 17 Reply 8 digits in hex separated by space disable auto stop disable automatic stop until using STOP command enable counter stop enable counter stop enable timer stop enable time...

Page 3: ...e GT_ACQ_FUL GateSync Full Data Acq Full data acquisition mode default GT_ACQ Ask Diff or Full Ask acquisition mode reply FUL or DIF Synchronous GATE signal data acquisition commands Gate synchronous...

Page 4: ...data from xxxx to yyyy xxxxyyyy K all ch read from xxxx to yyyy Available Hi speed read mode Reply hex GS RD Gate synchronous acq data read read gate synchronous data from xxxx to yyyy uvwxxxxyyyy u v...

Page 5: ...d w or w o ch uu to vv and timer timer data to download in sync with external gate signal ww 00 no timer data 01 timer data Reply dec w o H hex w H eXternal Synchronous DownLoad Read out the counter c...

Page 6: ...command internal ROM initialize command Please use it by USB communication when IP address became unknown or when a problem occurred and should be initialized INITROM Internal ROM data Initialize int...

Page 7: ...equest enable ZN counter clear by z phese sig Z phase counter clear cancel disable ZT counter clear timing set Select Z phase rising edge or Z phase falling edge to set the timing of clearing the coun...

Page 8: ...16 Counter start 16 Counter stop 16 Gate in enable disable 16 Read out and clear commands for counter and timer 17 Read out and clear commands for all counter and timer 17 Read out and clear commands...

Page 9: ...Encorder Counter 33 Read and Preset 33 Encorder Counter read command 33 Encorder Counter preset command 33 Encorder Counter setting 33 Direction of rotation and Count UP DOWN 33 Setting confirmation c...

Page 10: ...me time as the counter data of the data also ch8 ch9 of encoder counter In the case of the CT16 the data of the encoder counter will be collected at the same time as the counter data to ch16 ch17 Appe...

Page 11: ...switches on printed circuit board ON to OFF they changes OFF L This one is ETHERNET connection port It s adapted to 10BASE T 100BASE T communication This one is USB port Select Encorder Counter type...

Page 12: ...ng items by 10Base T 100Base T communication cable Setting protocol is telnet protocol by TCP IP connection To connect network by this one IP address subnet mask and Port NO must be set to this unit F...

Page 13: ...0 Confirm IP address IPA And return is as follow IPA192_168_001_060 Change port number PRTxxxx If you need to change port number to 10999 please execute the command as below PRT10999 Confirm port numb...

Page 14: ...munication Connect communication cables Connect communication cables Connect the communication cable to USB port or LAN port on rear panel There is no need to connect both side but there will be no pr...

Page 15: ...H because of internal pull up When gate signal has been changed to OFF the count data are stored in memory on synchronous gate data acquisition mode Memory size is about 5MB Data can be stored up to...

Page 16: ...tically stopped On synchronous gate data acquisition mode this command will be ignored 3 2 3 Stop disable by counter timer Type of command DSAS Disable to stop count by counter CH7 or timer Also memor...

Page 17: ...of counter operation 3 3 1 Counter start Type of command STRT Enable counter start 3 3 2 Counter stop Type of command STOP Enable counter stop Synchronous gate data acquisition is ended compulsorily...

Page 18: ...ata are 10 digit number in decimal The data order is CH0 CH1 CH2 CH7 timer Unit is cts for counter and s for timer Type of command RDALH To read all counter channels and timer in hexadecimal Reply exa...

Page 19: ...in order Unit is cts Type of command CLCTxx To clear the count value of counter channel xx CLCTxxyy To clear the count value from counter channel xx to channel yy CLPC To clear the count value of pres...

Page 20: ...adecimal data from the counter ch 0 to ch7 and the timer TSD 7 0 Download a hexadecimal data from only the counter ch 7 TSDLX H uuvvww The details of the timer synchronous download is specified If H i...

Page 21: ...above command 3 TSDSTRT The command is saved once it executes It is okay STRT command is executed before TSDSTRT or later The quantity of a data and the specification of a read interval which are down...

Page 22: ...890 2345678901 3456789012 0123456789 Returned in order with 10 figures of decimal numbers If 10 figures is exceeded it will be extended automatically A counter is a cts unit of measure Hexadecimal num...

Page 23: ...no overflow 3 6 Inquiry of software version information Type of command VER To inquiry about software version information Reply example 1 04 15 05 19 CT08 ER2 Reply is in order version number date an...

Page 24: ...r command FLG 0 Reply data 04 mean Counter number 2 overflow b7 b6 b5 b4 b3 Counter number 3 overflow b2 Counter number 2 overflow b1 Counter number 1 overflow b0 Counter number 0 overflow Reply for c...

Page 25: ...input COUNTING TIME SUSPENDING TIME 1ms GATE EDGE MODE Count data is stored on the memory at the falling edge of GATE signal Counter starts at the first falling edge of GATE signal after STRT command...

Page 26: ...ata acquisition end data address Type of command GSEDddd Set acquisition end data address Data acquisition stop automatically if current data address reach end address Type of command GSED Read data a...

Page 27: ...ata acquisition commands In this mode data acquisition is synchronized by clock generated by CT16 ER2 It s necessary to preset the value of clock ON time and clock OFF External gate input signal works...

Page 28: ...quired in the interval of 1ms 10ms the hexadecimal number conversion for high speed read does not meet to the end of data acquisition And this message is outputted to an enquiry till the completion of...

Page 29: ...end data address just after data acquisition Read out ch0 chX 1 X 16 32 48 64 ch0 ch1 ch timer Reply example 1DC2829F 07C38528 00FFE101 000161C602 Data of No 0 1DC2829F 07C38528 00FFE101 000161C602 D...

Page 30: ...xpresses x1000 Please use this for 9999 or more numbers Type of command GSCRD uvwxxxxyyyy Read out stored data from data address of xxxx to yyyy u read out start channel v end channel w if 1 read out...

Page 31: ...x1000 Please use this for 9999 or more numbers 4 5 5 LAN setup commands New LAN setting becomes effective if the one of three is executed Send the command RSET Push RES FWR switch 1sec at the front pa...

Page 32: ...ocessing time of an internal microcomputer and the speed of the communications department However since this counter uses the interface to LAN and DMA of a microcomputer it is downloadable at high spe...

Page 33: ...y K 3 Data download in decimal GSDAL GSDALX GSDRD xxxxyyyy GSDRDX xxxxyyyy K GSCRD uvwxxxxyyyy GSCRDX uuvvwwxxxxyyyy K Download Speed example note CT08 01E 8ch type was measured 16ch type 64ch type ar...

Page 34: ...e RB Decimal number Encorder Counter preset command Type of command SA must be in within 10digit Preset chA counter If the value is over the range maximun or minimum value is set Type of command SB mu...

Page 35: ...input or ZN command ch A Type of command Z Z phase counter clear cancel ch A Type of command ZT Select Z phase rising edge or Z phase falling edge to set the timing of clearing the counter ch A or ris...

Page 36: ...et offset range 0 2147483647 If the value is over the range maximun or minimum value is set ch A Decimal number Type of command OR Read out scaling paratmeter offset ch A Reply example O reply is sent...

Page 37: ...t value SDL00 17 To LCD lower line it shows one of a count value from ch0 to ch17 CT08 ER2 CH8 is Encorder A CH9 is Encorder B CT16 ER2 CH16 is Encorder A CH17 is Encorder SDLTM To LCD lower line it s...

Page 38: ...s started And then the file to write in is required soon It takes 1 to 2 seconds to write the version up file Press the Exit button to complete write in Please turn off the power switch and wait 5 to...

Page 39: ...end the command MIN10U to know the status reply is EN or DS 10 Regulations and guidelines Regarding CT16 ER2 when it receives data read command it stops count and timer action for 120 ns This stopping...

Page 40: ...witch all channels to TTL Hi Z termination THI x Switch channel x where x 0 2 4 14 to TTL Hi Z termination Channel x 1 s setting will follow that on channel x T50 ALL Switch all channels to TTL 50 Ohm...

Page 41: ...ER2 Windows control software which has been in use in CT08 01E will be used From our web site please download and use the latest version If you use this software you will be able to control the CT16 E...

Page 42: ...us gate signal save to RAM Over 1ms the total time of gate ON and OFF requires synchronous Store total data automatically up to 10 000 times on the clock mode timing of turning OFF synchronous clock s...

Page 43: ...Tsuji Electronics Co Ltd TEL 81 0 29 832 3031 FAX 81 0 29 832 2662 E mail info2 tsuji denshi co jp URL http www tsujicon jp 3739 Kandatsu machi Tsuchiura city Ibaraki 300 0013 Japan 43 43...

Reviews: