background image

TRT-BA-AIROZON10000-TC2020-19-002-EN

AIROZON 10000

EN

ORIGINAL INSTRUCTIONS

OZONE GENERATOR

Summary of Contents for AIROZON 10000

Page 1: ...TRT BA AIROZON10000 TC2020 19 002 EN AIROZON 10000 EN ORIGINAL INSTRUCTIONS OZONE GENERATOR ...

Page 2: ...tore the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or...

Page 3: ...e that the suction side is kept free of dirt and loose objects Specific safety warnings for the operation of ozone generators The device uses ozone for air purification It is a gas that due to its oxidative characteristics can cause severe health damage if inhaled Direct exposure to and intake of ozone is toxic for humans animals and plants For this reason the following safety measures must be obs...

Page 4: ... is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Warning Risk of injury caused by inhalation of ozone The following symptoms could be indicative of poisoning or an irritation caused by ozone eye irritations conjunctivitis stinging and watering eyes strong urge to cough shortness of ...

Page 5: ...cal energy or UV radiation It is these atoms that can react with the oxygen molecules to form ozone O3 In case of a high solar irradiation ozone forms involving other air pollutants The nitrogen oxides NOx from automobiles domestic heating systems power plants and the industry play a major role in this Depending on the concentration ozone can have a very intense smell similar to chlorine hay or ca...

Page 6: ... 6 7 8 9 10 No Designation 1 Housing 2 LED display 3 On off switch 4 Timer 5 Operating hours counter 6 Air outlet 7 Air inlet 8 Mains connection 9 Fan 10 High voltage unit Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitte...

Page 7: ... ground Position the device as close as possible to the centre of the room to ensure an optimum air circulation When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow Do not position the device near inflammable substances and gases Make sure that the air inlet and outlet are not obstructed Make sure that the de...

Page 8: ...n an input of minutes or hours Minutes Set the time unit selector switch 13 to M Hours Set the time unit selector switch 13 to H Use the time scale selector switch 12 to determine whether the indicator scale shall be used for 3 or 30 time units If 30 units have been set via the time unit selector switch the scale displays a time span of 0 30 time units If you selected the 3 time units setting the ...

Page 9: ...tch the device on by setting the on off switch 3 to position I ð Air purification will commence immediately 8 Exit the room directly after having started the device ð The ozone generator will now operate until the end of the set cleaning period Afterwards it will switch off automatically Operating parameters The duration of the cleaning process can differ depending on the conditions Factors to be ...

Page 10: ...ntly Available accessories Warning Only use accessories and additional equipment specified in the instructions Using insertion tools or accessories other than those specified in the instructions may cause a risk of injury Designation Article number Ozone warning sign ZZ7000275 Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur...

Page 11: ...valeting one can assume a maintenance rate of several months Criteria for determining the maintenance interval Device operation takes place frequently and several hours at a time on many days per month in excessively dirty surroundings in humid rooms Regardless of the described operating conditions you should perform maintenance work if one or more of the following signs become apparent increased ...

Page 12: ...sidues from the intermediate spaces Make sure that no fluff or fibres remain after cleaning 3 Do not use the device before the electrode has dried completely Technical annex Technical data Parameter Value Model Airozon 10000 Article number 1 180 000 112 Electric connection 230 V Frequency 50 60 Hz Max nominal current 1 5 A Max power input 230 W Ozone output 10 000 mg h Air flow rate 500 m h Sound ...

Page 13: ...mentioned in these instructions 14 15 5 6 7 8 9 10 11 12 13 1 2 3 4 Item Designation Item Designation 1 Griff 9 Betriebsstundenzähler 2 Deckel 10 Gehäuse 3 Abdeckung Luftfilter 11 Power Unit 4 Luftfilter 12 Sicherheitsschalter 5 Luftdruckmesser 13 Stromanschluss mit Sicherung 6 LED Licht 14 Ventilator 7 Ein Ausschalter 15 Hochspannungseinheit 8 Zeitschaltuhr o Abb Netzfilter ...

Page 14: ...ion of conformity The signed declaration of conformity can be found at https hub trotec com id 44531 Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A Herewith we Trotec GmbH declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 20...

Page 15: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: