background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

[email protected]

Model #: SMART700SER

SmartPro .7kVA Line Interactive UPS, Tower, Serial Port, 120V

 

Highlights

700VA line interactive tower UPS system

120V nominal output during brownouts to 75V and overvoltages to 147V

Front panel status LEDs with load and battery capacity level display

RS232 communications port; Hot-swappable batteries

NEMA 5-15P input; 6 NEMA 5-15R outlets

Description

 Tripp Lite's SMART 700SER is an intelligent, line-interactive UPS with DB9 serial port. It protects servers, networking accessories and
telecommunications equipment from blackouts, voltage fluctuations and transient surges. Large internal batteries offer 20 minutes half load runtime
and 6 minutes at full load during power failures. 700VA/450 watt power handling capability supports a variety of networking, telecom and various
other application types, including the support of multiple network workstations. Includes a total of 6 UPS supported outlets. Supports remote
monitoring of UPS and site power conditions via built-in DB9 serial port. Includes PowerAlert UPS monitoring and unattended shutdown software
with complete cabling. Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage
regulation and load level. Wall mountable with user-supplied UPSWM wallmount bracket. Network-grade AC surge suppression protects equipment
from damage and performance problems resulting from transient surges. Attractive, small-footprint tower housing uses minimal floor or desktop
space. 

Package Includes

SMART 700SER UPS System 

Monitoring cable 

PowerAlert unattended shutdown and UPS/Power monitoring software 

Instruction manual 

Features

700VA/450 watt power handling capability supports a variety of networking, telecom and various other application types 

Built-in voltage regulation and battery support, plus complete AC modem line surge suppression prevents equipment damage, data loss

and downtime 

Large internal batteries offer 20 minutes half load runtime and 6 minutes at full load during power failures 

Automatic Voltage Regulation (AVR) circuits with two boost and one voltage reduction level maintains usable 120V nominal output over an

input voltage range of 75-147V 

Includes a total of 6 NEMA5-15R outlets 

PowerAlert Software and DB9 serial communications port enable remote monitoring of UPS status and site power conditions; safe

unattended shutdown without data loss during extended power failures; messaging of UPS and line power status: on-battery, low-battery,

power-restored, AC line voltage, DC battery voltage and battery capacity 

Communications ports support timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected

equipment 

PowerAlert UPS monitoring and unattended shutdown software with complete cabling included 

Battery replacement door 

Notification of system status via 5 LEDs and multi-function audible alarms 

Wall mountable with user-supplied UPSWM wallmount bracket 

Cold start capability enables UPS turn-on in battery mode during blackout conditions 

Summary of Contents for SmartPro SMART700SER

Page 1: ...ge and performance problems resulting from transient surges Attractive small footprint tower housing uses minimal floor or desktop space Package Includes SMART 700SER UPS System Monitoring cable PowerAlert unattended shutdown and UPS Power monitoring software Instruction manual Features 700VA 450 watt power handling capability supports a variety of networking telecom and various other application ...

Page 2: ... INPUT Rated input current at maximum load 4 33A Nominal Input Voltage s Supported 120V AC UPS input connection type 5 15P Input circuit breaker 10A UPS Input cord length ft 7 UPS Input cord length m 2 1 Recommended Electrical Service 15A 120V BATTERY Full load runtime minutes 6 min 450w Half load runtime minutes 20 min 225w DC system voltage VDC 12 Battery recharge rate included batteries Less th...

Page 3: ... sound to indicate low battery status Switches 2 Switches control off on power status and alarm cancel self test operation SURGE NOISE SUPPRESSION UPS AC suppression joule rating 480 UPS AC suppression response time Instantaneous EMI RFI AC noise suppression Yes PHYSICAL Installation form factors supported with included accessories Tower Installation form factors supported with optional accessorie...

Page 4: ...p in battery mode during a power failure Cold start operation supported High availability UPS features Hot swappable batteries CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI WARRANTY Product Warranty Period Worldwide 2 year warranty 3 year with registration Note registration is required for 3 year warranty Connected Equipment Insurance ...

Page 5: ...4 washers 4 screws 1 Velcro safety strap 1 More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModelID 2670 Copyright 2012 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are...

Reviews: