SmartOnline 16kVA On-Line Double-Conversion
UPS, N+1, 12U Rack/Tower, 200-240V Hardwire
output

MODEL NUMBER: 

SU16KRTHW

 

 

 

Description

Tripp Lite SU16KRTHW 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete

power protection for critical server, network and telecommunications equipment in a 12U rack/tower

configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and

non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected

service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass

switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined

operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS

ideal for advanced networking applications in data centers, computer rooms, network closets and rugged

industrial locations.

Features

Tripp Lite SU16KRTHW 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration

Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under

Included Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load level

Hardwire input and output connections

Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal

Supports 50/60Hz operation for worldwide frequency compatibility

Expandable runtime with optional external battery packs

Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

Battery independent restart

Highly efficient economy mode option

Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module)

 Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module) 

HID-compliant USB interface

Highlights

16kVA / 16,000VA / 14,400W

on-line double-conversion UPS,

0.9 power factor

200/208/220/230/240V +/-2%

50/60Hz output, Economy mode

option

Hot-swap power & battery

modules, N+1 fault tolerance at

loads up to 8kVA

USB, RS232 & EPO ports,

support for SNMP/WEB & other

card options

Front panel LEDs with detailed

LCD monitoring and control

screen

Expandable runtime with optional

external battery packs

Hardwire input (3 wire), Hardwire

output

Package Includes

Two SU8000RT3UPM UPS

power modules

Two BP240V10RT3U battery

packs

SUPDMB20KHW PDU with

Bypass switch

4 post rackmount installation rails

PowerAlert software and cabling

1 / 6 

 

Содержание SmartOnline SU16KRTHW

Страница 1: ...th manual bypass switch enables hot swap replacement power modules at any supported load level Hardwire input and output connections Maintains full time sine wave output within 2 of selectable 200 208 220 230 240V nominal Supports 50 60Hz operation for worldwide frequency compatibility Expandable runtime with optional external battery packs Some external battery configurations require the use of T...

Страница 2: ...ously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95 or less Nominal Output Voltage s Supported 200V 208V 220V 230V 240V Nominal Voltage details Voltage selection via front panel LCD interfac...

Страница 3: ...tandard online double conversion mode Overvoltage correction Corrects overvoltages up to 300V Undervoltage correction Corrects undervoltages as low as 100V LEDS ALARMS SWITCHES LED Indicators 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD screen offers additional information and control options Front panel LCD display Selectable LCD display w...

Страница 4: ...UPM UPS Power modules and 2 BP240V10RT3U Battery packs Listed weights and dimensions for UPS Power module and Included battery pack each refer to a single unit Included battery pack dimensions height x width x depth inches 5 25 x 17 5 x 25 Included battery pack dimensions height x width x depth cm 13 3 x 44 5 x 63 5 Included battery pack weight lbs 158 7 Included battery pack weight kg 72 UPS Ship...

Страница 5: ...e 0 ms in online double conversion mode Transfer time economy mode 8 milliseconds typical power failure response in optional economy mode Low voltage transfer to battery power setpoint 100V High voltage transfer to battery power setpoint 300V SPECIAL FEATURES Cold Start startup in battery mode during a power failure Cold start operation supported Economy mode operation Optional economy mode enable...

Страница 6: ...External Battery Pack and Cable 3U Expandable Black 3 Point Connector 1 BP240V557C 1PH External battery pack for use with select Tripp Lite UPS Systems 1 BP240V787C 1PH External battery pack for use with select Tripp Lite UPS Systems 1 BP240V1037C 1PH External battery pack for use with select Tripp Lite UPS Systems 1 BP240V1407C 1PH External battery pack for use with select Tripp Lite UPS Systems ...

Отзывы: